Bid Publish Date
23-Oct-2026, 2:08 pm
Bid End Date
14-Nov-2026, 2:00 pm
EMD
₹16,000
Location
Progress
Public procurement opportunity for Directorate Of Health Services Kashmir Sodium-Potassium Electrolyte Analyzer, Semi-Automatic CBC Hematology Analyzer, Theatre-Grade Class B Autoclave, 100 mA High-Frequency Mobile X-Ray Plant, Dental Portable X-Ray at SDH Kokernag, Fully Automatic Biochemistry Analyzer (V2) (Q2) in ANANTHNAG, JAMMU & KASHMIR. Quantity: 6 issued by. Submission Deadline: 14-11-2026 14: 00: 00. View full details and respond.
Quantity
6
Category
Fully Automatic Biochemistry Analyzer (V2)
Bid Type
Two Packet Bid
Bid Validity
30 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
10
OEM Avg. Turnover
30
Past Performance
70 %
Warranty Period
2 years
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Sodium-Potassium Electrolyte Analyzer , Semi-Automatic CBC Hematology Analyzer , Theatre-Grade Class B Autoclave , 100 mA High-Frequency Mobile X-Ray Plant , Dental Portable X-Ray at SDH Kokernag , Fully Automatic Biochemistry Analyzer (V2) (Q2)
Advisory Bank
State Bank of India
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Anantnag
Delivery Pincodes
192126
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| MOHD SHAFI MALIK | 192126,BMO LARNOO | Anantnag | Jammu And Kashmir | 192126 | 1 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Sodium-Potassium Electrolyte Analyzer
Measurement modality - Advanced Direct Ion Selective Electrode (ISE) sensor matrix for maintenance-free operations. Target analytes - Quantitative evaluation of Sodium (Na) and Potassium (K) levels. Compatible with whole blood, serum, plasma, or diluted urine profiles. Fluidic system - Low-volume aspiration (not more than 100 uL) with automated self-calibrating diagnostic loops. Output - Integrated standalone thermal printing assembly for immediate data records.
Semi-Automatic CBC Hematology Analyzer
Diagnostic scope - 5-part differentiation of White Blood Cells (WBC), minimum 21 plus active parameters and full histograms for WBC, RBC, and PLT. Chassis design - Compact tabletop layout engineered for peripheral facility durability. Aspiration modality - Precise micro-capillary sampling module requiring low sample aspiration quantities. Interface and print - High-resolution color touchscreen interface with built-in thermal report printer.
Theatre-Grade Class B Autoclave
Sterilization cycles - Dual-mode selectable cycles at 121 degree C and 134 degree C with fractional vacuum pulses. Vacuum and pressure - High-efficiency vacuum pump drawing down to -0.8 bar, maximum operating pressure 2.2 bar to 2.4 bar. Locking and drying - Heavy-duty mechanical Rotary Lock Door System with electronic process safety interlocks. Automated pulse-vacuum drying phase ensuring 100 percent dry surgical packs with HEPA air intake filter. Power utility - Single-phase 220 V, 50/60 Hz power supply line.
100 mA High-Frequency Mobile X-Ray Plant
Generator core - High Frequency (HF) X-ray generator engine ensuring uniform output and low skin radiation dosage. Output rating - 100 mA at 100 kVp threshold configuration. Mechanical arm and chassis - Fully counterbalanced articulated arm for mechanical positioning across trauma beds and wards. Mobile lightweight construction mounted on high-grade anti-static steering castors.
Dental Portable X-Ray at SDH Kokernag
System type - Handheld, High-Frequency Digital Dental X-Ray System. Tube voltage/current - 60 kV to 70 kV / 2.0 mA to 3.0 mA. Focal spot size - not more than 0.4 mm for high spatial resolution. Exposure time - 0.01 s to 2.0 s (microprocessor controlled). Generator - High-Frequency Inverter (greater than 30 kHz). Safety and shielding - Built-in internal lead scatter shield, AERB Type Approved. Battery and power - Rechargeable Li-ion battery (minimum 150 exposures/charge) with charger. Compatibility - Digital Sensors (RVG), PSP plates, and film. Weight and ergonomics - Lightweight (not more than 2.5 kg) with dual-hand grip design. Accessories - Carry case, beam limiter/collimator, and user manual. Certifications - AERB Type Approval, CE / ISO certified.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Sodium-Potassium Electrolyte Analyzer | Measurement modality - Advanced Direct Ion Selective Electrode (ISE) sensor matrix for maintenance-free operations. Target analytes - Quantitative evaluation of Sodium (Na) and Potassium (K) levels. Compatible with whole blood, serum, plasma, or diluted urine profiles. Fluidic system - Low-volume aspiration (not more than 100 uL) with automated self-calibrating diagnostic loops. Output - Integrated standalone thermal printing assembly for immediate data records. | 1 | pieces | bmolarnooddo | 30 | |
| 2 | Semi-Automatic CBC Hematology Analyzer | Diagnostic scope - 5-part differentiation of White Blood Cells (WBC), minimum 21 plus active parameters and full histograms for WBC, RBC, and PLT. Chassis design - Compact tabletop layout engineered for peripheral facility durability. Aspiration modality - Precise micro-capillary sampling module requiring low sample aspiration quantities. Interface and print - High-resolution color touchscreen interface with built-in thermal report printer. | 1 | pieces | bmolarnooddo | 30 | |
| 3 | Theatre-Grade Class B Autoclave | Sterilization cycles - Dual-mode selectable cycles at 121 degree C and 134 degree C with fractional vacuum pulses. Vacuum and pressure - High-efficiency vacuum pump drawing down to -0.8 bar, maximum operating pressure 2.2 bar to 2.4 bar. Locking and drying - Heavy-duty mechanical Rotary Lock Door System with electronic process safety interlocks. Automated pulse-vacuum drying phase ensuring 100 percent dry surgical packs with HEPA air intake filter. Power utility - Single-phase 220 V, 50/60 Hz power supply line. | 1 | pieces | bmolarnooddo | 30 | |
| 4 | 100 mA High-Frequency Mobile X-Ray Plant | Generator core - High Frequency (HF) X-ray generator engine ensuring uniform output and low skin radiation dosage. Output rating - 100 mA at 100 kVp threshold configuration. Mechanical arm and chassis - Fully counterbalanced articulated arm for mechanical positioning across trauma beds and wards. Mobile lightweight construction mounted on high-grade anti-static steering castors. | 1 | pieces | bmolarnooddo | 30 | |
| 5 | Dental Portable X-Ray at SDH Kokernag | System type - Handheld, High-Frequency Digital Dental X-Ray System. Tube voltage/current - 60 kV to 70 kV / 2.0 mA to 3.0 mA. Focal spot size - not more than 0.4 mm for high spatial resolution. Exposure time - 0.01 s to 2.0 s (microprocessor controlled). Generator - High-Frequency Inverter (greater than 30 kHz). Safety and shielding - Built-in internal lead scatter shield, AERB Type Approved. Battery and power - Rechargeable Li-ion battery (minimum 150 exposures/charge) with charger. Compatibility - Digital Sensors (RVG), PSP plates, and film. Weight and ergonomics - Lightweight (not more than 2.5 kg) with dual-hand grip design. Accessories - Carry case, beam limiter/collimator, and user manual. Certifications - AERB Type Approval, CE / ISO certified. | 1 | pieces | bmolarnooddo | 30 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer