TenderDekho Logo
Active GEM

Government Tender Published for Diesel Power Generator (up to 900 KVA) in MUMBAI, MAHARASHTRA

Bid Publish Date

17-Jun-2026, 7:29 pm

Bid End Date

05-Aug-2026, 3:00 pm

EMD

₹1,96,000

Value

₹98,00,000

Generate Docs

Progress

Issue17-Jun-2026, 7:29 pm
Corrigendum22-Jul-2026
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

2

Bid Type

Two Packet Bid

Categories 5

N/a invites bids for Diesel Power Generator (up to 900 KVA) (Q2) in MUMBAI, MAHARASHTRA. Quantity: 2. Submission Deadline: 05-08-2026 15: 00: 00. Submit your proposal before the deadline.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

Diesel Power Generator (up to 900 KVA) (Q2)

Authority Records

MINISTRY OF CORPORATE AFFAIRS

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9362302.pdf

Main Document

GeM Category Specification

GEM_CATEGORY_SPECIFICATION

Other Documents

OTHER

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Installation Configuration Power Generator Installation Configurations as per CPWD General Specifications for Electrical Works – Part VII (DG Set) Fixed (Power Generators are permanently installed)"
Ratings Nominal Rated Capacity (in kVA) 500
Ratings Number of Phase Three Phase
Engine Rated Engine Power (kWm) 100 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator + Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience, 110 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience Or higher
Engine Type of Engine Cooling Liquid Cooled
Engine Type of Governor Electronic Or higher
Engine Number of Cylinders 6
Engine Rated Engine Speed (in RPM) 1500
Engine Type of Fuel High Speed Diesel (HSD)
Engine Starting Voltage (in volt) 24
Alternator Alternator Voltage Rating 415.0
Alternator Conformity to Indian Standard For Alternator Generally conforming to IS:13364 (Part-2) latest (Above 20 KVA)
Alternator Voltage Regulation Grade VG 1, VG 2, VG 3 Or higher
Alternator Alternator IP (Ingress Protection) Rating IP 23 Or higher
Control Panel Type of Control Panel AMF Control Panel
Control Panel Display Meters in Control Panel (with Appropriate Rating and Accuracy Class) - Included in Scope of Supply Voltmeter, Ammeter, Frequency meter, Power Factor meter, Multifunctional Digital display meter (displaying Voltage, Current, Frequency, Power Factor)
Control Panel Other Devices in Control Panel (with Appropriate Rating) - Included in Scope of Supply Required switches and cutout, MCB, MCCB, Contactor, Circuit breaker, Battery charger
Control Panel Display Parameters/Features [Hint:Products matching all selected values will be displayed; For example, if both 'Engine Speed' and 'Lube oil pressure' are selected, product that include both options will be shown] Engine Speed, Lube oil pressure, Coolant/cylinder head Temperature, Engine running hours, Engine battery voltage, Engine Running status, Generator Voltage (Ph-Ph), Generator Voltage (Ph-N), Generator Current (R, Y, B), Generator apparent Power (kVA), Generator active Power (kW), Powerfactor, Frequency, Fuel level, Event log, Control supply Voltage
Acoustic Enclosure Sheet Thickness (in mm) 1.6, 1.8, 2 Or higher
Fuel Tank Fuel Tank Capacity 700.0
Battery Battery Type "Low Maintenance free to IS: 14257 for high cranking performance"
Battery Number of Batteries 2
Trailer Availability of Trailer NA for Fixed/Skid Mounted Power Generator
Test Reports Type of lab which carried out test of complete product to prove the conformity of product specification Certificates required as per CPCB, Govt Lab, NABL accredited lab, NA
Test Reports Test Report Available For (Test/approval) Type Approval Certificate for the specified rating of the Power Generator from any of the designated agency authorized by CPCB, COP Certificate for engine, Type test report and Endurance test report for Engine as per IS: 10001 latest / IS: 10002 latest, Type test report for Alternator as per IS:13364 (Part-1) latest / IS:13364 (Part-2) latest to prove conformity to the specifications

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

Additional Doc 1 (Requested in ATC)

7

Additional Doc 2 (Requested in ATC)

8

Additional Doc 3 (Requested in ATC)

9

Additional Doc 4 (Requested in ATC)

10

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

11

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

3 Updates
#1

Update

22-Jul-2026

Extended Deadline

05-Aug-2026, 3:00 pm

Opening Date

05-Aug-2026, 3:30 pm

#2

Update

08-Jul-2026
#3

Update

08-Jul-2026

Extended Deadline

22-Jul-2026, 3:00 pm

Opening Date

22-Jul-2026, 3:30 pm