Bid Publish Date
17-Jun-2026, 7:29 pm
Bid End Date
05-Aug-2026, 3:00 pm
EMD
₹1,96,000
Value
₹98,00,000
Location
Progress
Quantity
2
Bid Type
Two Packet Bid
N/a invites bids for Diesel Power Generator (up to 900 KVA) (Q2) in MUMBAI, MAHARASHTRA. Quantity: 2. Submission Deadline: 05-08-2026 15: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Diesel Power Generator (up to 900 KVA) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
GEM_CATEGORY_SPECIFICATION
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
| Category | Specification | Requirement |
|---|---|---|
| Installation Configuration | Power Generator Installation Configurations as per CPWD General Specifications for Electrical Works – Part VII (DG Set) | Fixed (Power Generators are permanently installed)" |
| Ratings | Nominal Rated Capacity (in kVA) | 500 |
| Ratings | Number of Phase | Three Phase |
| Engine | Rated Engine Power (kWm) | 100 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator + Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience, 110 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience Or higher |
| Engine | Type of Engine Cooling | Liquid Cooled |
| Engine | Type of Governor | Electronic Or higher |
| Engine | Number of Cylinders | 6 |
| Engine | Rated Engine Speed (in RPM) | 1500 |
| Engine | Type of Fuel | High Speed Diesel (HSD) |
| Engine | Starting Voltage (in volt) | 24 |
| Alternator | Alternator Voltage Rating | 415.0 |
| Alternator | Conformity to Indian Standard For Alternator | Generally conforming to IS:13364 (Part-2) latest (Above 20 KVA) |
| Alternator | Voltage Regulation Grade | VG 1, VG 2, VG 3 Or higher |
| Alternator | Alternator IP (Ingress Protection) Rating | IP 23 Or higher |
| Control Panel | Type of Control Panel | AMF Control Panel |
| Control Panel | Display Meters in Control Panel (with Appropriate Rating and Accuracy Class) - Included in Scope of Supply | Voltmeter, Ammeter, Frequency meter, Power Factor meter, Multifunctional Digital display meter (displaying Voltage, Current, Frequency, Power Factor) |
| Control Panel | Other Devices in Control Panel (with Appropriate Rating) - Included in Scope of Supply | Required switches and cutout, MCB, MCCB, Contactor, Circuit breaker, Battery charger |
| Control Panel | Display Parameters/Features [Hint:Products matching all selected values will be displayed; For example, if both 'Engine Speed' and 'Lube oil pressure' are selected, product that include both options will be shown] | Engine Speed, Lube oil pressure, Coolant/cylinder head Temperature, Engine running hours, Engine battery voltage, Engine Running status, Generator Voltage (Ph-Ph), Generator Voltage (Ph-N), Generator Current (R, Y, B), Generator apparent Power (kVA), Generator active Power (kW), Powerfactor, Frequency, Fuel level, Event log, Control supply Voltage |
| Acoustic Enclosure | Sheet Thickness (in mm) | 1.6, 1.8, 2 Or higher |
| Fuel Tank | Fuel Tank Capacity | 700.0 |
| Battery | Battery Type | "Low Maintenance free to IS: 14257 for high cranking performance" |
| Battery | Number of Batteries | 2 |
| Trailer | Availability of Trailer | NA for Fixed/Skid Mounted Power Generator |
| Test Reports | Type of lab which carried out test of complete product to prove the conformity of product specification | Certificates required as per CPCB, Govt Lab, NABL accredited lab, NA |
| Test Reports | Test Report Available For (Test/approval) | Type Approval Certificate for the specified rating of the Power Generator from any of the designated agency authorized by CPCB, COP Certificate for engine, Type test report and Endurance test report for Engine as per IS: 10001 latest / IS: 10002 latest, Type test report for Alternator as per IS:13364 (Part-1) latest / IS:13364 (Part-2) latest to prove conformity to the specifications |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
05-Aug-2026, 3:00 pm
Opening Date
05-Aug-2026, 3:30 pm
Extended Deadline
22-Jul-2026, 3:00 pm
Opening Date
22-Jul-2026, 3:30 pm
Sign up now to access all documents
Main Document
GEM_CATEGORY_SPECIFICATION
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS