Bid Publish Date
12-Aug-2026, 3:05 pm
Bid End Date
02-Sep-2026, 3:00 pm
EMD
₹7,50,000
Value
₹7,06,76,760
Location
Progress
A tender has been published for N/a Distribution Transformer, 3 Phase, upto and Including 200 KVA ISI Marked To IS 1180 (Part 1) (Q2), Distribution Transformer, 3 Phase, 11 kV, >200 KVA upto and Including 2500 KVA ISI Marked To IS 1180 (Part 1) (Q2) in JAMMU, JAMMU & KASHMIR. Quantity: 260 by. Submission Deadline: 02-09-2026 15: 00: 00. Check eligibility and apply.
Quantity
260
Category
Distribution Transformer, 3 Phase, upto and Including 200 KVA ISI Marked To IS 1180 (Part 1)
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Item wise evaluation
Inspection Required
No
Tech Clarification Time
3 Days
EMD Required
Yes
MII Purchase Preference
No
MSE Purchase Preference
No
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
Yes
Min. Avg. Annual Turnover
212
OEM Avg. Turnover
212
Past Performance
20 %
Experience Required
2 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Distribution Transformer, 3 Phase, upto and Including 200 KVA ISI Marked To IS 1180 (Part 1) (Q2) , Distribution Transformer, 3 Phase, 11 kV, >200 KVA upto and Including 2500 KVA ISI Marked To IS 1180 (Part 1) (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
60
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
120
Delivery Locations
1
Delivery Cities
Jammu
Delivery Pincodes
180012
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Manjeet Singh | 180012,Office of the Executive Engineer JPDCL Eelctric Central Store Division Jammu Rail Head Complex Jammu | Jammu | Jammu And Kashmir | 180012 | 80 | 120 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
CATALOG Specification
OTHER
OTHER
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| STANDARDS | Energy Efficiency Level | 2 |
| STANDARDS | BEE Star Rating | 2, 3, 4, 5 Or higher |
| RATINGS | Nominal System Voltage, HV ( in kV) | 11 |
| RATINGS | Nominal System Voltage, LV ( in Volt) | 433 |
| RATINGS | Standard Ratings (in kVA) | 63 |
| RATINGS | Minimum Basic Insulation Level (in kVp) | 40, 60, 75, 125, 170 |
| RATINGS | No Load Voltage Ratios (in Volts) | 3300/433-250, 6600/433-250, 11000/433-250, 22000/433-250, 33000/433-250, 3300/250 (mid-point earth type), 6600/250 (mid-point earth type) |
| RATINGS | Highest System Voltage for Equipment (in kV) | 3.6, 7.2, 12, 17.5, 24, 36 |
| RATINGS | Rated Lightning Impulse withstand Voltage (in kV Peak) | 20, 40, 60, 85, 95, 125, 145, 170, 75 |
| CONSTRUCTION | Core Material | CRGO (as per IS:3024 latest) |
| CONSTRUCTION | Conductor (Winding) Material | Aluminium |
| CONSTRUCTION | Type of Mounting | Pole Mounted, Ground Mounted |
| TRANSFORMER TANK | Provision of Conservator | Yes , for Non sealed type with Plain tank construction, No |
| TAP CHANGER | Tap Changing Arrangement | On load, Off circuit , through link, Off circuit , externally operated switch with mechanical locking device and a position indicator, Off circuit, arrangement of locking at any tap position, Not applicable |
| TAP CHANGER | Winding Tapped | HV, Not applicable |
| OPTIONAL FITTINGS | Provision of Terminal Connectors | Yes, No, Yes including Oil temperature indicator and winding temperature indicator, Buchholz relay, Unidirectional flat rollers, Yes including Oil temperature indicator and winding temperature indicator, Buchholz relay, Unidirectional flat rollers, Jacking pads, magnetic oil gauge |
| OPTIONAL FITTINGS | Provision of Pressure Relief Device or Explosion Vent (upto 200 KVA doe non-sealed type transformer) | Yes, No |
| OPTIONAL FITTINGS | Provision of Protection Relay for Sealed-Type Transformers for Monitoring Internal Parameters (Pressure, Temperature, Oil Level, and Gas Detection) | Yes, No |