Bids are Invited For Echo Cardiography Scanning Machine (V2) in CENTRAL DELHI, DELHI

Bid Publish Date

10-Jun-2026, 2:02 pm

Bid End Date

09-Jul-2026, 3:00 pm

Progress

Issue10-Jun-2026, 2:02 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 3

N/a invites bids for Echo Cardiography Scanning Machine (V2) (Q2) in CENTRAL DELHI, DELHI. Quantity: 1. Submission Deadline: 09-07-2026 15: 00: 00. Submit your proposal before the deadline.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Echo Cardiography Scanning Machine (V2) (Q2)

Authority Records

MINISTRY OF HEALTH AND FAMILY WELFAREHEALTH AND FAMILY WELFARE DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 6

GeM-Bidding-9445828.pdf

Main Document

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Echo Cardiography Scanning Machine (V2)

N/a

CENTRAL DELHI, DELHI

Posted: 2 January 2025
Closed: 25 April 2025
GEM

Echo Cardiography Scanning Machine (V2)

N/a

CENTRAL DELHI, DELHI

Posted: 2 January 2025
Closed: 18 March 2025
GEM

Echo Cardiography Scanning Machine (V2)

Central Health Service Ministry Of Health And Family Welfare

NEW DELHI, DELHI

Posted: 8 February 2025
Closed: 15 March 2025
GEM

Echo Cardiography Scanning Machine (V2)

N/a

Posted: 1 January 2025
Closed: 29 January 2025
GEM

Echo Cardiography Scanning Machine (V2)

N/a

PONDICHERRY, PUDUCHERRY

Posted: 18 December 2024
Closed: 25 January 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Types of Probes & Features Cardiac and Vascular Probes Configuration TTE Phased Array, TTE Matrix Array, TEE Phased Array, TEE Matrix Array, Linear Probe
Types of Probes & Features TTE(Transthoracic) Probe Type Adult, Pediatric, Neonatal
Types of Probes & Features TEE Adult Probe biplane and Multiplane frequency, in MHz 2 to 7.5 MHz (±2), Not Applicable
Types of Probes & Features TEE Pediatric Probe Required Yes, No
Types of Probes & Features TEE Pediatric Probe frequency, in MHz 3 to 8 MHz (±2), Not Applicable
Types of Probes & Features Linear Probe for linear/ vascular applications required Yes, No
Types of Probes & Features Adult/Pediatric Linear probe frequency in MHz 5 to 14 MHz (±2), 5 to 10MHz (±2), Not Applicable
Types of Probes & Features No of Adult TTE Probes Required 1, NA
Types of Probes & Features No of Pediatric TTE Probes Required 1, NA
Types of Probes & Features No of Neonatal TTE Probes Required 1, NA
Types of Probes & Features No of Adult TEE Probes Required 1, NA
Types of Probes & Features No of Pediatric TEE Probes Required 1, NA
Types of Probes & Features No of Pediatric 3D/4D TEE Probes Required 1, NA
Types of Probes & Features No of Neonatal TEE Probes Required 1, NA
Types of Probes & Features No of Adult/pediatric Linear Probes supplied 1, NA
Types of Probes & Features Dedicated 3D/4D volume imaging for cardiology TTE ad TEE Yes, No
Types of Probes & Features Live 3 D imaging in color doppler system Yes, No
Types of Probes & Features Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval Yes, No
Types of Probes & Features Provision of Tissue Colorization (B-Colour) for improved contrast resolution Yes, No
Types of Probes & Features Application software Adult, Pediatric, Neonatal, Vascular applications and Transesophagal applications
Types of Probes & Features Cine Loop Features Yes, No
Types of Probes & Features Frame grabber facility for post analysis Yes, No
Types of Probes & Features Facility of Various maps for pre and post processing Yes, No
Types of Probes & Features ECG trigger facility Yes, No
Types of Probes & Features User defined Preset Yes, No
Types of Probes & Features Dedicated integrated dynamic stress echo package for flexible user defined protocols with stacked sub loops facility and contrast stress protocol usable for stress echocardiography Yes, No
Types of Probes & Features Number of transducer/probe ports 1, 2, 3, 4
Scan Modes and Performance Parameters Cardiac 3-D freehand Option Yes, No
Scan Modes and Performance Parameters Cardiac 3D/4D automatic Option Yes, No
Scan Modes and Performance Parameters Contrast Harmonic/Agent Imaging with angio mode Yes, No
Scan Modes and Performance Parameters Color Doppler 3-D/4-D option Yes, No
Scan Modes and Performance Parameters Power Dopple 3-D/4-D option Yes, No
Scan Modes and Performance Parameters Contrast-enhanced ultrasound (CEUS) option Yes, No
Scan Modes and Performance Parameters Tissue synchronization, tissue velocity Yes, No
Scan Modes and Performance Parameters Cardiac Shear wave elastography Yes, No
Scan Modes and Performance Parameters Cardiac compression elastography Yes, No
Scan Modes and Performance Parameters Provision for higher sensitivity for low frequency doppler in all probes Yes, No
Scan Modes and Performance Parameters Latest generation Electronic Phased/sector array Colour Doppler system Yes
Scan Modes and Performance Parameters Number of Channels in color doppler system 50000 or more (if channels are being designated as digital channels), 500000 or more (if channels are being designated as digital channels), 5000000 or more (if channels are being designated as digital channels), 128 or more (if channels are being designated as physical channels)
Scan Modes and Performance Parameters System should be capable of generating real time live 3- D images Yes, No, Yes with MV No Analysis
Image display and processing DICOM 3 Compliant Yes, No
Image display and processing Automated B-mode (2-D) image Yes, No
Image display and processing Automated CDI image optimization Yes, No
Image display and processing Automated PW Doppler image optimization Yes, No
Image display and processing Touch Screen Yes, No
Image display and processing Monitor display size, cm (in) 12 Inch(±1), 15 Inch(±1), 19 Inch(±1), 21 Inch(±1) Or higher
Image display and processing Split screen Twin View, Twin View and Live Quad Screen
Image display and processing Single/dual monitors Single, Single with optional second console, Dual (image display on touch panel)
Image display and processing Speckle-tracking strain and strain rate Yes, No
Image display and processing Analysis and calculation packages 2-D wall motion tracking, 3-D wall motion tracking, Cardiac, Mitral valve analysis, User-programmable calculations, No
Image display and processing Type of printer provided with the echo cardio machine Themal Printer, B/W Laser Printer, Color Laser Printer
Image display and processing Type of processor in PC i7 or Latest, NA
Image display and processing Conectivity between Echo cardiogram and PC Through IMS/Equivalent Software, NA
Image display and processing PC with all software inclusive interfaced with echocardiograph machine Yes, NA
Image display and processing Inkjet printer provided with computer for reporting Yes, No
Image display and processing Glossy Colour Print Paper supplied 500 sheets, 1000 sheets, Not provided
Image display and processing ECG Cable 2, NA
Image display and processing Echo cardiography sytem to be DICOM Ready Yes, No
Image display and processing Dicom Interfacability to HIS Yes, No
Image display and processing Dicom Interfacability Dicom to PACS Yes, No
Image display and processing Interfacability Dicom to RIS Yes, No

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

9

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found
Urgent

Echo Cardiography Scanning Machine (V2)

Central Health Service Ministry Of Health And Family Welfare

📍 NEW DELHI, DELHI

EMD: ₹5.0 L
Est: ₹2.5 Cr
⏰ Deadline: 7 days left
🛒 Type: Goods
View GEM
Urgent

Echo Cardiography Scanning Machine (V2)

Central Health Service Ministry Of Health And Family Welfare

📍 NEW DELHI, DELHI

EMD: ₹5.4 L
Est: ₹2.7 Cr
⏰ Deadline: 7 days left
🛒 Type: Goods
View GEM

Echo Cardiography Scanning Machine (V2)

Sree Chitra Tirunal Institute For Medical Sciences And Technology (sctimst)

📍 THIRUVANANTHAPURAM, KERALA

EMD: ₹7.0 L
Est: ₹3.0 Cr
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM

Echo Cardiography Scanning Machine (V2)

Sree Chitra Tirunal Institute For Medical Sciences And Technology (sctimst)

📍 THIRUVANANTHAPURAM, KERALA

EMD: ₹6.0 L
Est: ₹2.4 Cr
⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM

Ultrasound Machine (V2)

Assam Medical Services Corporation Limited

📍 TINSUKIA, ASSAM

⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM