SPECTROPHOTOMETER
Directorate Of Forensic Science
Menu
Public procurement opportunity for National Forensic Sciences University SPECTROPHOTOMETER (Q2) in JAIPUR, RAJASTHAN. Quantity: 2 issued by. Submission Deadline: 17-12-2025 17: 00: 00. View full details and respond.
Directorate Of Forensic Science
Government Science College Idar
SABARKANTHA, GUJARAT
Oil India Limited
Employees State Insurance Corporation (esic)
VARANASI, UTTAR PRADESH
Commissionerate Of Technical Education
AHMEDABAD, GUJARAT
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| LIGHT SOURCE | Light Source | Halogen Lamp, Deuterium Lamp, LED, Tungsten Halogen Lamp, Xenon Flash |
| LIGHT SOURCE | Diffraction Grating (lines/mm) | 600, 800, 1000, 1200, 1400, 1600, 1800 |
| LIGHT SOURCE | Switching of Light Source | Automatic, Mannual, NA |
| LIGHT SOURCE | Wavelength Setting And Scanning | Automatic, Mannual |
| TYPE | Type of Spectrophotometer | UV - VISIBLE, VISIBLE, UV - VISIBLE - IR, NIR, UV-VIS, UV-Visible spectrophotometer, double beam/split beam, microprocessor controlled with dual source assembly |
| TYPE | Type of Optical System | Single Beam, Split Beam, Double Beam |
| TYPE | Monochromator Type | Reflexive Grating, Holographic Grating, Czerny-turner, NA, Scanning grating |
| TYPE | Detector Type | Photo Multiplier Tube (PMT), Photodiode, CMOS, Diode array, Silicon, Silicon & Lead Sulfide, Indium Gallium Arsenide (InGaAs) |
| TYPE | Spectral Bandwidth Type | Fixed Bandwidth, Variable Bandwidth |
| OPTICAL PERFORMANCE | Source Wavelength - Minimum | 175, 180, 185, 190, 195, 200, 320, 340, 400, 570, 850, 950, 460 |
| OPTICAL PERFORMANCE | Source Wavelength - Maximum | 320, 340, 760, 780, 900, 960, 1000, 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650, 644 Or higher |
| OPTICAL PERFORMANCE | Resolution | 0.002, 0.3, 0.5, 1, 1.25, 1.5, 1.7, 2, 0.2, 0.01 |
| OPTICAL PERFORMANCE | Wavelength Accuracy (+/-) | 0.1, 0.3, 0.5, 0.8, 1, 1.5, 2, 2.5, 0.05 |
| OPTICAL PERFORMANCE | Bandwidth (nm) | 0.1, 0.2, 0.5, 1, 1.5, 1.8, 2.0, 4.0, 5.0, 0.1 to 5.0, 7, 8.5 |
| OPTICAL PERFORMANCE | Focal length (mm) | 0 to 49, 50 to 99, 100 to 149, 150 to 199, 200 to 249, 250 to 299, 300 and above |
| OPTICAL PERFORMANCE | Photometric measurement modes | Transmittance, Absorbance, Concentration (Wavelength, time), Reflectance, Energy, Polarisation |
| OPTICAL PERFORMANCE | Photometric Absorbance (Max) (Abs) (+/-) | 0.2 - 8 |
| OPTICAL PERFORMANCE | Photometric Absorbance Accuracy (Max) (+/-) | 0.001 - 0.5 |
| OPTICAL PERFORMANCE | Photometric Transmittance (Max) (+/-) | 0 - 100 |
| OPTICAL PERFORMANCE | Photometric Transmittance Accuracy (Max) (+/-) | 0 - 0.5 |
| OPTICAL PERFORMANCE | Photometric Reflectance (Max) (+/-) | 0 - 100 |
| GENERIC | Display | In-built display, Through PC |
| GENERIC | Display type | LCD with Backlight, LED, LCD touchscreen, TFT, NA |
| GENERIC | Display Size | 0 - 30 |
| GENERIC | Test result printing | Through inbuilt Printer, Through external printer |
| GENERIC | If inbuilt printer, Type of printer | Thermal printer, Dot matrix, Laser b/w, Inkjet b/w, Color laser, Color inkjet, N/A |
| GENERIC | Internal storage(GB) | 0 - 80 |
| GENERIC | Mximum Path Length of sample | 0 - 120 |
| GENERIC | Number of Cuvettes supplied-inclusive in the scope of supply | 10, 25, 50, 100, 200, 300, 400, 500, 2, 4, 6, 8, 0 |
| GENERIC | Spares and Consumables inclusive in the scope of supply | Yes, No |
| OPERATING CONDITIONS | Minimum Operating Temperature | -5, -10, 0, 5, 10 |
| OPERATING CONDITIONS | Maximum Operating Temperature | 35, 40, 45, 50, 55, 60 |
| OPERATING CONDITIONS | Operating Humidity (RH) (%) at 40 degree C | 80, 85, 90, 95 |
| WARRANTY | Onsite Warranty | 1, 2, 3, 4, 5 |
| WARRANTY | Availability of Spares (at extra cost) | 2, 3, 4, 5, 6, 7, 8, 10 |
| Certification | Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements | Yes, No |
| Certification | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | Yes, No |
| Certification | Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification | Yes, No |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Kamdhenu University
📍 ANAND, GUJARAT
Kamdhenu University
📍 ANAND, GUJARAT
Indian Space Research Organization
📍 AHMEDABAD, GUJARAT
Mahatma Gandhi Government Arts College Mahe
📍 KANNUR, KERALA
Kamdhenu University
📍 ANAND, GUJARAT
Sign up now to access all documents
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Choose from flexible plans to access tender documents instantly
Main Document
OTHER
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS