Bid Publish Date
25-Aug-2026, 2:30 pm
Bid End Date
04-Sep-2026, 3:00 pm
Location
Progress
A tender has been published for Industrial Training Institute Handheld Digital Infrared Thermometer (Q3) in GURGAON, HARYANA. Quantity: 2 by. Submission Deadline: 04-09-2026 15: 00: 00. Check eligibility and apply.
Quantity
2
Bid Type
Two Packet Bid
Bid Validity
30 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
2 Days
EMD Required
No
MII Purchase Preference
No
MSE Purchase Preference
No
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Past Performance
20 %
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Handheld Digital Infrared Thermometer (Q3)
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
15
Delivery Locations
1
Delivery Cities
Gurugram
Delivery Pincodes
122001
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Jitender | 122001,GOVT. ITI MEHRAULI GURGAON ROAD, OPP. SECTOR 14, GURUGRAM | Gurugram | Haryana | 122001 | 2 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| PERFORMANCE (INFRARED / NON-CONTACT) | Lowest Measurable Temperature (Infrared Non-contact) | -70, -60, -50, -40, -35, -33, -32, -30, -25, -20 Or lower |
| PERFORMANCE (INFRARED / NON-CONTACT) | Highest Measurable Temperature (Infrared Non-contact) | 500, 535, 550, 600, 650, 700, 750, 760, 800, 900, 950, 1000, 1050, 1100, 1200, 1300, 1370, 1400, 1470, 1500, 1600, 1700, 1800, 1850, 1900, 2000, 2100, 2200, 2300, 2400, 2500, 2600, 2700, 2800, 2900, 3000 Or higher |
| PERFORMANCE (INFRARED / NON-CONTACT) | Display Resolution | 0.1, 0.2, 0.5, 1 Or lower |
| PERFORMANCE (INFRARED / NON-CONTACT) | Basic Accuracy (±) | 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 5 Or lower |
| PERFORMANCE (INFRARED / NON-CONTACT) | Emissivity (W/m2) | Continuously Adjustable from 0.1 to 1.00, Fixed at 0.95, > 0.95 |
| DISPLAY / DATA OUTPUT | Type of Display | LCD, LED, OLED |
| DISPLAY / DATA OUTPUT | Back-light display | Yes, No |
| DISPLAY / DATA OUTPUT | Display Size(in inch) | 2.0 to 2.4, 2.5 to 2.9, 3.0 to 3.4, 3.5 to 3.9, 4.0 to 4.4, 4.5 to 4.9, 5.0 to 5.4, 5.5 to 5.9, 6.0 to 6.4, 6.5 to 6.9 Or higher |
| DISPLAY / DATA OUTPUT | Data Output to other devices | Yes, No |
| DISPLAY / DATA OUTPUT | Data point logging capability (on board memory) | 0, 10, 12, 20, 30, 40, 50, 100, 200, 500, 1000, 2000, 3000, 4000, 4999 Or higher |
| SALIENT FEATURES / FUNCTIONS | Salient Features / Functions | Datahold, Data Recall, Integral Tripod Mount, Built-In Laser Sighting, Fahrenheit and Celsius Conversion, Hazardous location approval, Date and Time Stamping, High and Low audible alarm, Low Battery indication, Trigger lock for continuous monitoring, Maximum and Minimum Reading, Average and Differential reading, Integrated thermocouple Input for contact Measurement |
| ACCESSORIES | Standard accessories inclusive in the scope of supply | Data output cabkle, Data transfer software, Battery Charger, Adhesive Tape Roll, Belt Holder, Wrist Strap, Neck Strap, Carrying Case, Instruction booklet, User Manual, Air Probe-T/C Type K, Food Probe-T/C Type K, Immersion Tip-T/C Type K, Immersion/Penetration Probe-T/C Type K, Thermocouple with TC adapter-T/C Type K, RTD Sensor, Calibration Points, Emissivity Reference Chart |
| GENERIC | Built-in laser for precisely aiming the target | Yes, No |
| GENERIC | Laser Class | Class I, Class II, NA |
| GENERIC | Laser sighting | Single-point laser, Dual laser, Three dot laser, NA |
| GENERIC | Optional/User Guide/Manual | Yes, No |
| OPERATING CONDITIONS / INGRESS PROTECTION | Minimum Operating Temperature | 0, -5, -10, -15, -20, -25, -30 Or lower |
| OPERATING CONDITIONS / INGRESS PROTECTION | Maximum Operating Temperature | 50, 55, 60, 65, 70 Or higher |
| OPERATING CONDITIONS / INGRESS PROTECTION | Maximum Operating Humidity at 40 deg C - Non-condensing (Rh) | 65, 70, 75, 80, 85, 90, 95 Or higher |
| WARRANTY | Warranty | 1, 2, 3, 4, 5 |
| CERTIFICATION / TEST REPORTS | Hazardous location (Intrinsically Safe / non-incendive) approval | Yes, No |
| CERTIFICATION / TEST REPORTS | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | Yes, No |