High End Multipara Monitor (V3)
Directorate Of Medical Education And Training
SIDDHARTHNAGAR, UTTAR PRADESH
Bid Publish Date
18-May-2026, 1:50 pm
Bid End Date
08-Jun-2026, 5:00 pm
EMD
₹1,75,200
Location
Progress
Quantity
16
Bid Type
Two Packet Bid
All India Institute Of Medical Sciences (aiims) has released a public tender for High End Multipara Monitor (V3) (Q2) in NADIA, WEST BENGAL. Quantity: 16. Submission Deadline: 08-06-2026 17: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
High End Multipara Monitor (V3) (Q2)
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
OTHER
OTHER
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Directorate Of Medical Education And Training
SIDDHARTHNAGAR, UTTAR PRADESH
N/a
GAUTAM BUDDHA NAGAR, UTTAR PRADESH
N/a
TIRUCHIRAPPALLI, TAMIL NADU
Aligarh Muslim University (amu)
ALIGARH, UTTAR PRADESH
All India Institute Of Medical Sciences (aiims)
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Product Specifications | Type of Monitor | Modular |
| Product Specifications | Monitoring Parameters | ECG, HR, Respiration Rate, SpO2, Pulse Rate, NIBP, Temperature, IBP |
| Product Specifications | EtCO2 | Upgradable |
| Product Specifications | Cardiac output | Minimal invasive (Continuous), Invasive (Thermodilution), Non invasive (Continuous), NA |
| Product Specifications | Transport monitor module with basic vital parameters for transporting within the hospital | No, Yes |
| Product Specifications | Screen size of transport module( in inches ) | 4.3 inch or more, NA |
| Product Specifications | AGM (Anesthetic Gas Module) | AGM With O2, Upgradable |
| Product Specifications | NMT (Neuro Muscular Transmission) | Yes, Upgradable |
| Product Specifications | EEG (Electroencephalogram) | Yes, Upgradable |
| Product Specifications | AEEG (Amplitude Integrated Electroencephalography)Trend Graph | Yes, Upgradable |
| Product Specifications | Channels in EEG | 8, NA |
| Product Specifications | Depth of Anesthesia Monitoring | Yes, Upgradable |
| Product Specifications | Spirometry | Yes, Upgradable |
| Product Specifications | Non invasive hemoglobin | Yes, Upgradable |
| Product Specifications | PVI (Pleth variability index) | No, Yes |
| Product Specifications | Perfusion Index | Yes |
| Product Specifications | Transcutaneous PO2 / PCO2 | Yes, Upgradable |
| Product Specifications | S T Analysis | Yes |
| Product Specifications | PPV (derived value during IBP measurement) | Yes |
| Product Specifications | Regional Oximetry | Yes, Upgradable |
| Product Specifications | Length of time of full disclosure of patient data in hr | ≥ 72 Or higher |
| Product Specifications | Length of time of trending in hr | ≥ 72 Or higher |
| ECG PARAMETERS | ECG Provided | Yes |
| ECG PARAMETERS | Number of leads of ECG | 3, 5, 6, 10 |
| ECG PARAMETERS | 12-Lead interpretation for ECG | Yes |
| ECG PARAMETERS | ECG Waveform number of leads display | 12 |
| ECG PARAMETERS | Arrhythmia detect | Yes |
| ECG PARAMETERS | Heart rate measurement range | Atleast 30 -250 bpm |
| ECG PARAMETERS | Accuracy | ± 2 bpm or better |
| ECG PARAMETERS | Minimum gradation | 1 bpm or better |
| RESPIRATION PARAMETERS | Respiration Method | Impedance pneumography |
| RESPIRATION PARAMETERS | Display waveform of respiration | Yes |
| RESPIRATION PARAMETERS | Respiration rate measurement range | 0 - 100 bpm or more, 0 - 150 bpm or more |
| RESPIRATION PARAMETERS | Minimum gradation of respiratory measurement | 1 bpm or better |
| PULSE OXIMETERY PARAMETERS | Measurement technique (Declaration of the measurement technique by the seller at the time of bid submission/supply) | Low Perfusion Technology with Motion artifact detection |
| PULSE OXIMETERY PARAMETERS | Probe type | Clip |
| PULSE OXIMETERY PARAMETERS | Probe for Adult and Pediatric | Reusable |
| PULSE OXIMETERY PARAMETERS | Probe for neonates | Reusable |
| PULSE OXIMETERY PARAMETERS | SPO2 measurement range | 40 - 100%, 70 - 100% |
| NIBP PARAMETERS | Systolic Blood pressure monitoring range | 30 - 300 mmHg or more, 40 - 250 mmHg or more, 40 - 270 mmHg or more |
| NIBP PARAMETERS | Diastolic Blood pressure monitoring range | 10 - 200 mmHg or more, 30 - 220 mmHg or more |
| TEMPERATURE PARAMETERS | Type of probe | Skin |
| IBP PARAMETERS | Number of channels for IBP | 2, 3, 4, 8 |
| ETCO2 PARAMETERS | Sensor type | Mainstream, Sidestream, Microstream, NA |
| ETCO2 PARAMETERS | Patient type | Non intubated, Intubated and non intubated |
| DISPLAY PARAMETERS | Display Size in inches | 10, 12, 15, 17, 19 Or higher |
| DISPLAY PARAMETERS | Traces of display | >6, >10, >12, >14 |
| DISPLAY PARAMETERS | User Interface of display | Touchscreen, Touchscreen and Rotary knob Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Air Force
📍 CHANDIGARH, CHANDIGARH
N/a
📍 PATAN, GUJARAT
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
South Eastern Coalfields Limited
📍 BILASPUR, CHHATTISGARH
All India Institute Of Medical Sciences (aiims)
📍 WEST DELHI, DELHI
Sign up now to access all documents
Main Document
OTHER
OTHER
OTHER
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS