Translational Health Science And Technology Institute Automated Blood Culture System Tender India 2025
Translational Health Science And Technology Institute (thsti)
FARIDABAD, HARYANA
Bid Publish Date
25-Jun-2026, 1:30 pm
Bid End Date
16-Jul-2026, 2:00 pm
EMD
₹25,000
Value
₹25,00,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Directorate Of Medical Education And Training announces a tender for Automated Blood Culture System (Q2) in AGRA, UTTAR PRADESH. Quantity: 1. Submission Deadline: 16-07-2026 14: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Automated Blood Culture System (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Translational Health Science And Technology Institute (thsti)
FARIDABAD, HARYANA
N/a
KHORDHA, ODISHA
Directorate Of Health Services
CHURACHANDPUR, MANIPUR
N/A
MUMBAI, MAHARASHTRA
N/A
JODHPUR, RAJASTHAN
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Automated Blood Culture System |
| PRODUCT INFORMATION | Technology | Fluorometric technology / Colorimetric technology / Non-radiometric technology |
| PRODUCT INFORMATION | Patient usage | Adult and Pediatric |
| PRODUCT INFORMATION | Type of Culture Bottles Supported | Aerobic, Anaerobic, Fungal |
| PRODUCT INFORMATION | Sample Capacity (Minimum) | 40 bottles or more, 80 bottles or more, 120 bottles or more, 200 bottles or more, 360 bottles or more Or higher |
| PRODUCT INFORMATION | System should have the capability of continuous monitoring of all samples for growth of micro-organisms | Yes |
| PRODUCT INFORMATION | System should be able to display growth kinetics on the screen and have the capacity to generate hard copy of each growth kinetics | Yes |
| PRODUCT INFORMATION | System should have the facility to analyse delayed specimens with the routine bottles | Yes |
| PRODUCT INFORMATION | System should be having continuous agitation and incubation facility to provide optimal growth of microorganisms | Yes |
| PRODUCT INFORMATION | System should have in-built calibration check / facilitate calibration | Yes |
| PRODUCT INFORMATION | Media bottles should have the capacity to neutralize antibiotics | Yes |
| PRODUCT INFORMATION | Visual and audible alarms for positive cultures | Yes |
| PRODUCT INFORMATION | Every cell (bottle position) have its own optics and detection device | Yes |
| PRODUCT INFORMATION | System should have data management system and software to analyze and store the data | Yes |
| PRODUCT INFORMATION | Barcode Reader | Built-in / External |
| DATA MANAGEMENT SYSTEM | Type of monitor | Inbuilt / PC Based |
| DATA MANAGEMENT SYSTEM | Type of monitor display | LCD / LED |
| DATA MANAGEMENT SYSTEM | Touch screen display | Yes |
| DATA MANAGEMENT SYSTEM | UPS provided for Power Backup facility | Yes, No |
| DATA MANAGEMENT SYSTEM | UPS Back up time in minutes | 30 minutes or more, 60 minutes or more, NA if no UPS provided |
| DATA MANAGEMENT SYSTEM | Availability of external printer | Yes, No |
| DATA MANAGEMENT SYSTEM | Connectivity | LIS / HIS compatibility |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Conformity to electrical safety requirements | IEC 60601 / 61010 latest amended or BIS equivalent |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5.0, 1.0 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Hll Infra Tech Services Limited
South Western Railway
All India Institute of Medical Sciences-Bhubaneswar
📍 KHORDHA, ODISHA
N/a
📍 MAHASAMUND, CHHATTISGARH
N/a
📍 CENTRAL DELHI, DELHI
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS