Bid Publish Date
30-Oct-2025, 1:30 pm
Bid End Date
01-Dec-2025, 6:00 pm
Value
₹4,07,808
Location
Progress
Bharat Sanchar Nigam Limited Portal(bsnl) announces a tender for Supply Installation Testing and commissioning of 200kVA 11KV by 430V 50Hz ONAN outdoor distribution transformer sealed type corrugated tank as per IS1180 Part 1, Miscellaneous and statutory utility linked charges covering 11 kV gang operation GOAB DO switching isolation discharge earthing shutdown coordination permits Inspectorate CEI fees if applicable, Dismantling of existing faulty burnt 200 KVA Transformer from the plinth foundation, Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire 11 KV overhead lines with rated voltage 9 KV rms, Supplying and erection of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required in PAPUM PARE, ARUNACHAL PRADESH. Quantity: 5. Submission Deadline: 01-12-2025 18: 00: 00. Last date to apply is approaching fast!
Quantity
5
Category
Supply Installation Testing and commissioning of 200kVA 11KV by 430V 50Hz ONAN outdoor distribution transformer sealed type corrugated tank as per IS1180 Part 1
Bid Type
Two Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
Min. Avg. Annual Turnover
2
OEM Avg. Turnover
2
Past Performance
80 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Supply Installation Testing and commissioning of 200kVA 11KV by 430V 50Hz ONAN outdoor distribution transformer sealed type corrugated tank as per IS1180 Part 1 , Miscellaneous and statutory utility linked charges covering 11 kV gang operation GOAB DO switching isolation discharge earthing shutdown coordination permits Inspectorate CEI fees if applicable , Dismantling of existing faulty burnt 200 KVA Transformer from the plinth foundation , Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire 11 KV overhead lines with rated voltage 9 KV rms , Supplying and erection of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Supply Installation Testing and commissioning of 200kVA 11KV by 430V 50Hz ONAN outdoor distribution transformer sealed type corrugated tank as per IS1180 Part 1
Supply Installation Testing and commissioning of 200kVA 11KV by 430V 50Hz ONAN outdoor distribution transformer sealed type corrugated tank as per IS1180 Part 1 with standard fittings including Transportation loading unloading first fill mineral oil routine test certificates and inspection etc as required
Miscellaneous and statutory utility linked charges covering 11 kV gang operation GOAB DO switching isolation discharge earthing shutdown coordination permits Inspectorate CEI fees if applicable
Miscellaneous and statutory utility linked charges covering 11 kV gang operation GOAB DO switching isolation discharge earthing shutdown coordination permits Inspectorate CEI fees if applicable metering testing sealing NABL oil test liaison documentation temporary fencing traffic management security RoW municipal fees if any
Dismantling of existing faulty burnt 200 KVA Transformer from the plinth foundation
Dismantling of existing faulty burnt 200 KVA Transformer from the plinth foundation by disconnecting of power supply including liasioning with DOPAP Authorities etc as required
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire 11 KV overhead lines with rated voltage 9 KV rms
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire 11 KV overhead lines with rated voltage 9 KV rms with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement G I bolts nut washers etc as required
Supplying and erection of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required
Supplying and erection of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Supply Installation Testing and commissioning of 200kVA 11KV by 430V 50Hz ONAN outdoor distribution transformer sealed type corrugated tank as per IS1180 Part 1 | Supply Installation Testing and commissioning of 200kVA 11KV by 430V 50Hz ONAN outdoor distribution transformer sealed type corrugated tank as per IS1180 Part 1 with standard fittings including Transportation loading unloading first fill mineral oil routine test certificates and inspection etc as required | 1 | job | sde_e_ne21 | 60 | |
| 2 | Miscellaneous and statutory utility linked charges covering 11 kV gang operation GOAB DO switching isolation discharge earthing shutdown coordination permits Inspectorate CEI fees if applicable | Miscellaneous and statutory utility linked charges covering 11 kV gang operation GOAB DO switching isolation discharge earthing shutdown coordination permits Inspectorate CEI fees if applicable metering testing sealing NABL oil test liaison documentation temporary fencing traffic management security RoW municipal fees if any | 1 | job | sde_e_ne21 | 60 | |
| 3 | Dismantling of existing faulty burnt 200 KVA Transformer from the plinth foundation | Dismantling of existing faulty burnt 200 KVA Transformer from the plinth foundation by disconnecting of power supply including liasioning with DOPAP Authorities etc as required | 1 | job | sde_e_ne21 | 60 | |
| 4 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire 11 KV overhead lines with rated voltage 9 KV rms | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire 11 KV overhead lines with rated voltage 9 KV rms with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement G I bolts nut washers etc as required | 1 | set | sde_e_ne21 | 60 | |
| 5 | Supplying and erection of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required | Supplying and erection of 11 KV pin insulator complete with large steel head G I pin nuts washers etc as required | 1 | set | sde_e_ne21 | 60 |
Extended Deadline
01-Dec-2025, 12:30 pm
Opening Date
01-Dec-2025, 1:00 pm
Extended Deadline
01-Dec-2025, 11:30 am
Opening Date
01-Dec-2025, 12:00 pm
Extended Deadline
27-Nov-2025, 11:30 am
Opening Date
27-Nov-2025, 12:00 pm
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer