SITC of Air Handling Units with DX coil VRF Outdoor Units with Copper piping Ducting Civil works
Security Printing And Minting Corporation Of India Limited (spmcil)
NASHIK, MAHARASHTRA
Progress
Quantity
397
Category
SITC of DX type Precision Air Conditioning Unit
Bid Type
Two Packet Bid
Indian Space Research Organization invites bids for SITC of DX type Precision Air Conditioning Unit, Supply of 18G hard drawn copper pipe, Laying of 18G hard drawn copper pipe, Supply laying and termination of copper flexible cable, Supply laying and termination of Inter looping Cable between Indoor Units, Supply laying and termination of copper flexible cable as required between Isolator in door unit, supply and installation of drain piping, Supply and Installation of CPVC humidifier piping 25mm, Supply and installation of Ball Valves, Supply of first charge of refrigerant in BANGALORE, KARNATAKA. Quantity: 397. Submission Deadline: 09-07-2026 15: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
SITC of DX type Precision Air Conditioning Unit , Supply of 18G hard drawn copper pipe , Laying of 18G hard drawn copper pipe , Supply laying and termination of copper flexible cable , Supply laying and termination of Inter looping Cable between Indoor Units , Supply laying and termination of copper flexible cable as required between Isolator in door unit , supply and installation of drain piping , Supply and Installation of CPVC humidifier piping 25mm , Supply and installation of Ball Valves , Supply of first charge of refrigerant
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Security Printing And Minting Corporation Of India Limited (spmcil)
NASHIK, MAHARASHTRA
Office Of Dg R & D (r & M)
SOUTH DELHI, DELHI
Airports Authority Of India
MUMBAI, MAHARASHTRA
Translational Health Science And Technology Institute (thsti)
FARIDABAD, HARYANA
Translational Health Science And Technology Institute (thsti)
FARIDABAD, HARYANA
Tender Results
Loading results...
SITC of DX type Precision Air Conditioning Unit
SITC of 21 plus or minus 1 TR Cooling Capacity with minimum12000 CFM low height front discharge High sensible DX type Precision Air Conditioning Unit Specification as per Annexure I and II enclosed
Supply of 18G hard drawn copper pipe
Supply of 18G hard drawn copper pipe between PAC and outdoor unit with fitting bends brazing work etc
Laying of 18G hard drawn copper pipe
Laying of 18G hard drawn copper pipe between PAC and outdoor unit with fitting bends brazing work etc
Supply laying and termination of copper flexible cable
Supply laying and termination of suitable size and rating PVC insulated PVC Sheathed IS confirm copper flexible cable as required between IDU and ODU for control wiring Cabling with 8 SWG GI earthing wire
Supply laying and termination of Inter looping Cable between Indoor Units
Supply laying and termination of suitable size and rating copper PVC insulated cable for Inter looping Cable between Indoor Units for Auto sequencing
Supply laying and termination of copper flexible cable as required between Isolator in door unit
Supply laying and termination of suitable size and rating PVC insulated PVC Sheathed IS confirm copper flexible cable as required between Isolator and in door unit
supply and installation of drain piping
Supply and Installation of CPVC drain piping clamps and supports U trap has to be provided near all the units 40mm dia as per site requirement with 9mm thick insulation
Supply and Installation of CPVC humidifier piping 25mm
Supply and Installation of CPVC humidifier piping 25mm dia as per site requirement inclusive of isolation valves and accessories
Supply and installation of Ball Valves
Supply and installation of Ball Valves for Hot and Liquid line
Supply of first charge of refrigerant
Supply of first charge of refrigerant and Testing and Commissioning of the above 2 nos PAC units
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | SITC of DX type Precision Air Conditioning Unit | SITC of 21 plus or minus 1 TR Cooling Capacity with minimum12000 CFM low height front discharge High sensible DX type Precision Air Conditioning Unit Specification as per Annexure I and II enclosed | 2 | nos | [email protected] | 120 | |
| 2 | Supply of 18G hard drawn copper pipe | Supply of 18G hard drawn copper pipe between PAC and outdoor unit with fitting bends brazing work etc | 120 | rmt | [email protected] | 120 | |
| 3 | Laying of 18G hard drawn copper pipe | Laying of 18G hard drawn copper pipe between PAC and outdoor unit with fitting bends brazing work etc | 120 | rmt | [email protected] | 120 | |
| 4 | Supply laying and termination of copper flexible cable | Supply laying and termination of suitable size and rating PVC insulated PVC Sheathed IS confirm copper flexible cable as required between IDU and ODU for control wiring Cabling with 8 SWG GI earthing wire | 80 | rmt | [email protected] | 120 | |
| 5 | Supply laying and termination of Inter looping Cable between Indoor Units | Supply laying and termination of suitable size and rating copper PVC insulated cable for Inter looping Cable between Indoor Units for Auto sequencing | 10 | rmt | [email protected] | 120 | |
| 6 | Supply laying and termination of copper flexible cable as required between Isolator in door unit | Supply laying and termination of suitable size and rating PVC insulated PVC Sheathed IS confirm copper flexible cable as required between Isolator and in door unit | 20 | rmt | [email protected] | 120 | |
| 7 | supply and installation of drain piping | Supply and Installation of CPVC drain piping clamps and supports U trap has to be provided near all the units 40mm dia as per site requirement with 9mm thick insulation | 20 | rmt | [email protected] | 120 | |
| 8 | Supply and Installation of CPVC humidifier piping 25mm | Supply and Installation of CPVC humidifier piping 25mm dia as per site requirement inclusive of isolation valves and accessories | 20 | rmt | [email protected] | 120 | |
| 9 | Supply and installation of Ball Valves | Supply and installation of Ball Valves for Hot and Liquid line | 4 | nos | [email protected] | 120 | |
| 10 | Supply of first charge of refrigerant | Supply of first charge of refrigerant and Testing and Commissioning of the above 2 nos PAC units | 1 | lot | [email protected] | 120 |
Discover companies most likely to bid on this tender
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Bharat Sanchar Nigam Limited Portal(bsnl)
📍 KAMRUP, ASSAM
Airports Authority Of India
📍 DIMAPUR, NAGALAND
Centre For Development Of Advanced Computing (c-dac)
📍 GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Nhpc Limited
📍 DHEMAJI, ASSAM
Punjab National Bank (pnb)
📍 CENTRAL DELHI, DELHI
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS