Progress
Indian Space Research Organization invites bids for Spectrum Analyzers and Vector Network Analyzers (Q3) in BANGALORE, KARNATAKA. Quantity: 6. Submission Deadline: 02-09-2026 17: 00: 00. Submit your proposal before the deadline.
Quantity
6
Bid Type
Two Packet Bid
Bid Validity
120 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
4 Days
EMD Required
No
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Warranty Period
3 years
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Spectrum Analyzers and Vector Network Analyzers (Q3)
Advisory Bank
State Bank of India
ePBG Percentage
3%
ePBG Duration (Months)
41
Max Delivery Days
90
Delivery Locations
1
Delivery Cities
Bengaluru Urban
Delivery Pincodes
560058
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Keshavamurthy S R | 560058,Plot No. 12 and 13, 3rd Main, 2nd Phase, Peenya Industrial Area, Bangalore | Bengaluru Urban | Karnataka | 560058 | 6 | 90 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| FEATURES | Description of the itemuu | Spectrum analyzers |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Markers | Normal, delta |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Trigger | Free run, video, External |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Display | Internal TFT/LCD Color Display with provision for six traces |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Interface | USB, LAN |
| GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER | Software for transfer of screen shot/measurement data to PC | Yes |
| SPECTRUM ANALYZER FEATURES | Frequency Range | 10 Hz to 13 GHz |
| SPECTRUM ANALYZER FEATURES | Aging rate of spectrum analyzer frequency: Better than 1x10-6 /Year | Yes |
| SPECTRUM ANALYZER FEATURES | Frequency counter Resolution(minimum) (Hz) | 0.001Hz |
| SPECTRUM ANALYZER FEATURES | Frequency Span | 100Hz to 13GHz |
| SPECTRUM ANALYZER FEATURES | Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz | SSB Phase Noise @ 10KHz offset , at 1GHz shall be less than -100dBc/Hz |
| SPECTRUM ANALYZER FEATURES | Spectral purity:Harmonics @ -40dBm level <=60 dBc | yes |
| SPECTRUM ANALYZER FEATURES | Sweep time @span >or= 1 KHz | 1 mS to 4000 S |
| SPECTRUM ANALYZER FEATURES | Sweep time @span = 0 Hz | 1microS - 1000sec |
| SPECTRUM ANALYZER FEATURES | Resolution Bandwidth (-3dB) | 1Hz to 10MHz in steps |
| SPECTRUM ANALYZER FEATURES | Video Bandwidth | 1Hz to 10MHz in steps. |
| SPECTRUM ANALYZER FEATURES | Amplitude : Max input level for protection (dBm) | +30 |
| SPECTRUM ANALYZER FEATURES | Amplitude : Max input level for measurement (dBm) | 20 |
| SPECTRUM ANALYZER FEATURES | Amplitude :level measurement uncertainity (dB) | <=1, <=±1 |
| SPECTRUM ANALYZER FEATURES | Average noise level displayed(@300HzRBW,10Hz VBW) | <=-140dBm for 10MHz to 3 GHz |
| SPECTRUM ANALYZER FEATURES | Average noise level displayed(@100HzRBW,1Hz VBW) | <= -140dBm for 13GHz to 26 GHz, <= -140dBm For 3GHz to 13GHz |
| SPECTRUM ANALYZER FEATURES | Average noise level displayed(@300HzRBW,1Hz VBW) | <=-110dBm for 10MHz to 3 GHz, <= -125dBm for 3GHz to 13 GHz |
| SPECTRUM ANALYZER FEATURES | Measurement features | C/N ratio,AM%,time domain power measurement,channel power measurement,Phase noise measurement,TOI(THIRD ORDER INTERCEPT),OBW(occupied bandwidth) |
| VECTOR NETWORK ANALYZER FEATURES | Frequency Range for 2port vector network analyzer | NA |
| VECTOR NETWORK ANALYZER FEATURES | Frequency Resolution (CW ON) (Hz) | NA |
| VECTOR NETWORK ANALYZER FEATURES | Return Loss (dB) | NA |
| VECTOR NETWORK ANALYZER FEATURES | VSWR (dB) | NA |
| VECTOR NETWORK ANALYZER FEATURES | Cable Loss (dB) | NA |
| VECTOR NETWORK ANALYZER FEATURES | Calibration with Precision calibration components-open, short, load should be included to achieve directivity >35 dB hint: NA for items designated as spectrum analyzers | NA |
| VECTOR NETWORK ANALYZER FEATURES | Abilty to locate Distance-to-fault in Co-axial cables | NA |
| VECTOR NETWORK ANALYZER FEATURES | Phase Range (degree) | NA |
| VECTOR NETWORK ANALYZER FEATURES | Phase Resolution (deg) | NA |
| VECTOR NETWORK ANALYZER FEATURES | RF output port | NA |
| VECTOR NETWORK ANALYZER FEATURES | Dynamic Range | NA |
| VECTOR NETWORK ANALYZER FEATURES | Nominal port power output: Hi Power/Lo-Power selectable | NA |
| VECTOR NETWORK ANALYZER FEATURES | Measurement of S11 and S21 and Smith Chart | NA |
| VECTOR NETWORK ANALYZER FEATURES | Vector Voltmeter for comparision and verification of the phase of the phase-matched cables | NA |
| OPERATING CONDITIONS | Operating Temperature | 0 to 50 degree C & 80% RH @ 40 degree C |
| OPERATING CONDITIONS | Operating Humidity | 90% @ 40deg. C |
| POWER REQUIREMENT | Power requirement | 230 +- 10 VAC, 50Hz |
| POWER REQUIREMENT | chemistry of the battery | NA |
| POWER REQUIREMENT | Suitable charger / adaptor provided | NA |
| WARRANTY | Warranty | 3, 4, 5 Or higher |
| CERTIFICATION/TEST REPORT DETAILS | The equipment supplied with calibration certificate | yes |
| CERTIFICATION/TEST REPORT DETAILS | conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:9000/part-3/section-5/1977 latest | no |
| CERTIFICATION/TEST REPORT DETAILS | conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:9000/part-2/section-4/1977 latest | no |
| CERTIFICATION/TEST REPORT DETAILS | conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH | no |
| CERTIFICATION/TEST REPORT DETAILS | Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification | Yes |