Bid Publish Date
06-Mar-2025, 11:55 pm
Bid End Date
29-Mar-2025, 2:00 pm
Location
Progress
Quantity
7304
Indian Army has released a public tender for Taking down of light fittings of any type size and model complete all as specified and directed. , Ta in HOOGHLY, WEST BENGAL. Quantity: 7304. Submission Deadline: 29-03-2025 14: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_CATEGORY_SPECIFICATION
GEM_CATEGORY_SPECIFICATION
GEM_CATEGORY_SPECIFICATION
GEM_GENERAL_TERMS_AND_CONDITIONS
Taking down of light fittings of any type size and model complete all as specified and directed.
Taking down of light fittings of any type size and model complete all as specified and directed.
Taking down of brackets of any type size and model complete all as specified and directed.
Taking down of brackets of any type size and model complete all as specified and directed.
M and L in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts
M& L in repair steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP 22 (8.5 metres long) complete all as specified & directed.
M and L in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws
M& L in repair steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP 31 (9 metres long) complete all as specified & directed.
Re fixing of LED street light fittings of any wattage outdoor type complete all as specified and directed.
Re fixing of LED street light fittings of any wattage outdoor type complete all as specified and directed.
Supply and fixing in repair LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum
Supply and fixing in repair LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics,efficacy 110/120 LPW, complete with IP 65/66 protection complete all as specified and directed.
S and F in repair LED flood light 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped
Supply and fixing in repair LED flood light 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,efficacy 110/120 LPW,including clamp,nut,bolts etc.complete all as specified and directed.Make. Crompton,cat No.LFL 80 CDL/60 HPM
S and F in repair LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66
Supply and fixing in repair LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,efficacy 110/120 LPW,including clamp,nut,bolts etc.complete all as specified and directed.Make. Crompton,cat No.LFLN 150 CDL/60 M
S and F Cable Junction Box 155X210X92 mm in size made out of thermoplastic having IP 66 protection for outdoor installation fixed with 4 way bakelite
S&F Cable Junction Box 155X210X92 mm in size, made out of thermoplastic, having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M 32 02 No & M 25 01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. Make. Cat No. DK 1616G of HENSEL or equivalent model
Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor and sheathed flexible
Supply and passing through steel tubler pole/service connection, 1100 volts grade multicore,FR, round insulated copper conductor and sheathed flexible cable,multistranded, three core of nominal cross sectonal area 1.5 Sq mm,for connection of security light from junction box through pole /conduit with all terminals complete all as specified and as directed.
S and F single arm bracket made of40mm dia 1.0mtrs long for security light
S and F single arm bracket made of40mm dia 1.0mtrs long for security light, with mounting MS clamp of flat iron size 25X5mm of suitable length 02 pairs including nut bolt etc of suitable size and painting to MS clamp with two coats of aluminium paints over a coat of red oxide netal primer all as specified and directed by Engr In Charge.
S and F in repair Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees
S & F in repair Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks,clamps etc. all as specified and directed by Engr In charge.
M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground
M and L for earthing complete with MS galvanised plate of size 60cmX60cmX6mm as earth electrode buried directly in ground earth pit not less tan 2.25mtrs deep below ground level with top edge of the plate not less tan 1.5mtrs below normal ground level connected to galvaniosed iron strip 32X6mm as earthing lead by means of bolts nut check nut and washers of galvanised iron welding or steel all as shown in electrical plate no 3 in ssr part I of 2009 connected to earthing test point all as specified complete with exevation and earth work pcc pit with 6mm thick ci ms cover having suitable handle 10mm MS rod with frame and locking arrangement 20mm dia gi med grade watering pipe with funnel with wire mesh 40mm bore gi pipe med grade isi marked for protection of earth lead conductor and testing completion complete all as specified and directed by EIC NOTE. earth test report to submitted by contractor to this office 2. erth should be not more than specific value.
Taking down out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks
Taking down/out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re use, complete all as specified and as directed. (NOTE. Earth Work shall be Measured and Paid for separately under relevant Items).
Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth Taking Out and Laying of Cables etc
Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil
Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed.
Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed.
Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed.
M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread
M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE. For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid ).
M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed.
M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and as directed.
Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable
Supply and laying for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 4 core.
Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty 10 sqmm 4 core.
Supply and laying for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core.
Re Laying Fixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable
Re Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross Sectional Area 10 Sqmm 2 Core to 25 Sqmm 4 Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed.
S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc.
S & F 40 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed .
S and F Galvanised Iron Pipe 40mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole etc.
S&F Galvanised Iron Pipe 40mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed.
Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc. 10.00 mtr
Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note. Pipe to be measured separately.
M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces
M&L for PCC (1.2.4) type B1 (using 20 mm graded aggregate) as in coping for pole including form work and finishing the surfaces even and smooth,dismantling etc complete all as specified and as directed.
M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc
M&L for PCC 1.3.6 type C2 (using 40 mm graded aggregate) as in foundation for pole etc complete all as specified and as directed.
S and F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection
S & F HDPE DWC (Double Walled Corrugated) of Diameter 25 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as directed.
M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | Taking down of light fittings of any type size and model complete all as specified and directed. | Taking down of light fittings of any type size and model complete all as specified and directed. | 12 | each | [email protected] | 90 | |
| 2 | Taking down of brackets of any type size and model complete all as specified and directed. | Taking down of brackets of any type size and model complete all as specified and directed. | 12 | each | [email protected] | 90 | |
| 3 | M and L in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts | M& L in repair steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP 22 (8.5 metres long) complete all as specified & directed. | 10 | each | [email protected] | 90 | |
| 4 | M and L in repair steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws | M& L in repair steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP 31 (9 metres long) complete all as specified & directed. | 2 | each | [email protected] | 90 | |
| 5 | Re fixing of LED street light fittings of any wattage outdoor type complete all as specified and directed. | Re fixing of LED street light fittings of any wattage outdoor type complete all as specified and directed. | 10 | each | [email protected] | 90 | |
| 6 | Supply and fixing in repair LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum | Supply and fixing in repair LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics,efficacy 110/120 LPW, complete with IP 65/66 protection complete all as specified and directed. | 200 | each | [email protected] | 90 | |
| 7 | S and F in repair LED flood light 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped | Supply and fixing in repair LED flood light 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,efficacy 110/120 LPW,including clamp,nut,bolts etc.complete all as specified and directed.Make. Crompton,cat No.LFL 80 CDL/60 HPM | 10 | each | [email protected] | 90 | |
| 8 | S and F in repair LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 | Supply and fixing in repair LED flood light 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,efficacy 110/120 LPW,including clamp,nut,bolts etc.complete all as specified and directed.Make. Crompton,cat No.LFLN 150 CDL/60 M | 35 | each | [email protected] | 90 | |
| 9 | S and F Cable Junction Box 155X210X92 mm in size made out of thermoplastic having IP 66 protection for outdoor installation fixed with 4 way bakelite | S&F Cable Junction Box 155X210X92 mm in size, made out of thermoplastic, having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M 32 02 No & M 25 01 No) fixed on poles with Aluminium clamps of size 25x3mm, nuts, bolts, washers etc. including taking out of old unserviceable cable junction box complete all as specified and as directed. Make. Cat No. DK 1616G of HENSEL or equivalent model | 210 | each | [email protected] | 90 | |
| 10 | Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor and sheathed flexible | Supply and passing through steel tubler pole/service connection, 1100 volts grade multicore,FR, round insulated copper conductor and sheathed flexible cable,multistranded, three core of nominal cross sectonal area 1.5 Sq mm,for connection of security light from junction box through pole /conduit with all terminals complete all as specified and as directed. | 1,600 | rm | [email protected] | 90 | |
| 11 | S and F single arm bracket made of40mm dia 1.0mtrs long for security light | S and F single arm bracket made of40mm dia 1.0mtrs long for security light, with mounting MS clamp of flat iron size 25X5mm of suitable length 02 pairs including nut bolt etc of suitable size and painting to MS clamp with two coats of aluminium paints over a coat of red oxide netal primer all as specified and directed by Engr In Charge. | 200 | each set | [email protected] | 90 | |
| 12 | S and F in repair Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees | S & F in repair Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks,clamps etc. all as specified and directed by Engr In charge. | 1,600 | rm | [email protected] | 90 | |
| 13 | M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground | M and L for earthing complete with MS galvanised plate of size 60cmX60cmX6mm as earth electrode buried directly in ground earth pit not less tan 2.25mtrs deep below ground level with top edge of the plate not less tan 1.5mtrs below normal ground level connected to galvaniosed iron strip 32X6mm as earthing lead by means of bolts nut check nut and washers of galvanised iron welding or steel all as shown in electrical plate no 3 in ssr part I of 2009 connected to earthing test point all as specified complete with exevation and earth work pcc pit with 6mm thick ci ms cover having suitable handle 10mm MS rod with frame and locking arrangement 20mm dia gi med grade watering pipe with funnel with wire mesh 40mm bore gi pipe med grade isi marked for protection of earth lead conductor and testing completion complete all as specified and directed by EIC NOTE. earth test report to submitted by contractor to this office 2. erth should be not more than specific value. | 20 | each set | [email protected] | 90 | |
| 14 | Taking down out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks | Taking down/out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks, GI Pipes, etc. of any descriptions, laid in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz Bricks, Cables, GI Pipes, etc. and keep in Safe custody for re use, complete all as specified and as directed. (NOTE. Earth Work shall be Measured and Paid for separately under relevant Items). | 720 | rm | [email protected] | 90 | |
| 15 | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth Taking Out and Laying of Cables etc | Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, Taking Out and Laying of Cables, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed. | 158 | cum | [email protected] | 90 | |
| 16 | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil | Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. | 91 | cum | [email protected] | 90 | |
| 17 | Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. | Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. | 67 | cum | [email protected] | 90 | |
| 18 | M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread | M&L Sand Cushioning (dry) in Trenches for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE. For the purpose of Payment, Punned thickness of Sand Cushioning only shall be Measured and Paid ). | 50 | cum | [email protected] | 90 | |
| 19 | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. | M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and as directed. | 5 | per 1000 nos | [email protected] | 90 | |
| 20 | Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable | Supply and laying for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 4 core. | 100 | rm | [email protected] | 90 | |
| 21 | Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty 10 sqmm 4 core. | Supply and laying for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 10 sqmm 4 core. | 420 | rm | [email protected] | 90 | |
| 22 | Re Laying Fixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable | Re Laying/Fixing or Passing through Pipe, XLPE insulated, Armoured, Electric Power UG Cable (Heavy Duty) with Aluminium Conductor, 1100 Volt Grade, Nominal Cross Sectional Area 10 Sqmm 2 Core to 25 Sqmm 4 Core including Brass Compression Cable Gland, Terminal Lug, etc. complete all as specified and as directed. | 200 | rm | [email protected] | 90 | |
| 23 | S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. | S & F 40 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed . | 50 | rm | [email protected] | 90 | |
| 24 | S and F Galvanised Iron Pipe 40mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole etc. | S&F Galvanised Iron Pipe 40mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. | 36 | rm | [email protected] | 90 | |
| 25 | Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc. 10.00 mtr | Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note. Pipe to be measured separately. | 36 | rm | [email protected] | 90 | |
| 26 | M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces | M&L for PCC (1.2.4) type B1 (using 20 mm graded aggregate) as in coping for pole including form work and finishing the surfaces even and smooth,dismantling etc complete all as specified and as directed. | 1 | cum | [email protected] | 90 | |
| 27 | M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc | M&L for PCC 1.3.6 type C2 (using 40 mm graded aggregate) as in foundation for pole etc complete all as specified and as directed. | 6 | cum | [email protected] | 90 | |
| 28 | S and F HDPE DWC Double Walled Corrugated of Diameter 25 mm including disconnection and connection | S & F HDPE DWC (Double Walled Corrugated) of Diameter 25 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as directed. | 720 | rm | [email protected] | 90 | |
| 29 | M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn | M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire | 720 | rm | [email protected] | 90 |
Extended Deadline
29-Mar-2025, 2:00 pm
Opening Date
29-Mar-2025, 2:30 pm
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | BHARAT CONSTRUCTION Under PMA | - | 28-03-2025 16:11:31 | |
| 2 | J.K. AND COMPANY Under PMA | - | 28-03-2025 14:56:16 | |
| 3 | NORTHERN CABLE FAULT LOCATORS Under PMA | - | 27-03-2025 15:01:07 |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | BHARAT CONSTRUCTION(MII) Under PMA | Item Categories : Taking down of light fittings of any type size and model complete all as specified and directed.,Ta | |
| L2 | J.K. AND COMPANY (MSE,MII)( MSE Social Category:General ) Under PMA | Item Categories : Taking down of light fittings of any type size and model complete all as specified and directed.,Ta | |
| L3 | NORTHERN CABLE FAULT LOCATORS (MSE,MII)( MSE Social Category:General ) Under PMA | Item Categories : Taking down of light fittings of any type size and model complete all as specified and directed.,Ta |
Key insights about WEST BENGAL tender market
The eligibility requirements include being a registered entity with relevant statutory compliance. Bidders must demonstrate previous experience in similar projects and should hold all necessary licenses and certifications. Additionally, they should comply with health and safety regulations that apply to electrical work.
Bidders must demonstrate the ability to handle technical specifications related to electrical installations, including the ability to dismantle and re-install various types of lighting. Compliance with established quality standards and sound knowledge of electrical safety practices is mandatory.
Payment terms typically include milestones based on project completion stages or a lump sum upon completion and satisfactory inspection of the work. Bidders must ensure they inform themselves about diverse payment terms as outlined in the tender documents.
Submit all relevant documents electronically through the designated portal, ensuring they meet all specified formats and compliance details outlined in the documentation. Adherence to submission methods is crucial for successful participation.
Yes, this tender includes specific provisions for Micro, Small, and Medium Enterprises (MSEs), which may entail relaxed eligibility criteria, subsidized fees, and potential benefits in the evaluation process aimed at promoting participation from smaller entities.
This comprehensive coverage ensures potential bidders are informed and prepared to engage with this tender effectively.
Sign up now to access all documents
Main Document
BOQ
BOQ
GEM_CATEGORY_SPECIFICATION
GEM_CATEGORY_SPECIFICATION
GEM_CATEGORY_SPECIFICATION
GEM_GENERAL_TERMS_AND_CONDITIONS