Dr Bhubanesar Borooah Cancer Institute Bbci announces a tender for High Flow Nasal Oxygen Therapy Unit (V2) (Q2) in KAMRUP, ASSAM. Quantity: 16. Submission Deadline: 03-09-2026 11: 00: 00. Last date to apply is approaching fast!
Quantity
16
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
3 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Warranty Period
2 years
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
High Flow Nasal Oxygen Therapy Unit (V2) (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
29
Pre-Bid Date
12-08-2026 15:00:00
Pre-Bid Venue
Pre-Bid Meeting will be held on 12.08.2026 at 03.00 P.M. onwards at Conference room, Administrative Block, Dr. B. Borooah Cancer Institute, Guwahati. Online Meeting link : https://us02web.zoom.us/j/7371316170?pwd=34TRR6W mzq9QdbbfjOrfsOQbwnZbiZ.1&omn=87883909863 Topic: Pre-Bid Meeting "High Flow Nasal Oxygen Therapy unit" Time: Aug 12, 2026 15:00 PM India Meeting ID: 737 131 6170 Passcode: bbci@1234 *Clarification, if any, shall be discussed during pre-bid meeting. *Please be advised that any representations, if applicable, must be submitted through the Clarification tab of the GeM portal within the deadline for seeking clarifications. Representations submitted outside the GeM Portal or via email or in any other mode will not be considered for discussion.
Max Delivery Days
60
Delivery Locations
1
Delivery Cities
Kamrup Metro
Delivery Pincodes
781016
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Ph Surachandra Singha | 781016,Dr. Bhubaneswar Borooah Cancer Institute, AK Azad Road, Gopinath Nagar Rd, Bishnu Rabha Nagar, Guwahati, Assam 781016. | Kamrup Metro | Assam | 781016 | 16 | 60 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
CATALOG Specification
OTHER
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| GENERAL FEATURES | Product Description | High Flow Nasal Oxygen Therapy Unit |
| GENERAL FEATURES | Usage | Single system for treating infants, pediatric and adult patients |
| PRODUCT INFORMATION | Delivers | Warm and Humidified Oxygen |
| PRODUCT INFORMATION | Flow generator | In-built |
| PRODUCT INFORMATION | Delivery range | 2 to 60 liters/minute, 2 to 70 liters/minute Or higher |
| PRODUCT INFORMATION | Flow range of generator for Pediatric mode | 2 - 25 litres/minute |
| PRODUCT INFORMATION | Flow range of generator for Adult mode | 10 - 60 litres/minute |
| PRODUCT INFORMATION | Air/oxygen blender | In-built |
| PRODUCT INFORMATION | FiO2 monitoring | Yes |
| PRODUCT INFORMATION | Delivery range of oxygen concentration (FiO2) | 21% to 100 % Or higher |
| PRODUCT INFORMATION | Accuracy for FiO2 | ± 2.5 % Or higher |
| PRODUCT INFORMATION | Air source | Inbuilt without need for external compressor |
| PRODUCT INFORMATION | Humidifier | Integrated heated humidifier |
| PRODUCT INFORMATION | Patient Interface | Nasal cannula |
| PRODUCT INFORMATION | Disinfection of device | No disinfection required |
| PRODUCT INFORMATION | Heated disinfection tube for sterilization of the device provided | NA |
| PRODUCT INFORMATION | Provided with a flow meter assembly with clamp and markings to read flows above 60 liters along with a high pressure tubing to connect with an oxygen source | Yes |
| PRODUCT INFORMATION | Storage of records | 10000 or more Or higher |
| DISPLAY | Type of display | LCD Color Display, LED Color Display |
| DISPLAY | Parameters monitored and displayed | Flow, FiO2, Temperature, Humidity, Mode whether adult or pediatric, Faults |
| ALARMS | Alarms available | Tubes disconnect leaks alarm, Tube blockages alarm, Mismatching of tubes (Adult vs Pediatric) alarm, Alarm for oxygen concentration high and low, Hardware fault alarm with error codes, Power failure alarm, Alarm for low water level before the water completely dries out in the humidifier, Indication of air filter change due |
| ALARMS | Type of alarm indication | Both audible and visual alarms |
| ACCESSORIES | Accessories provided | One trolley/Pole with castors having a mounting platform/tray and a rack |
| ACCESSORIES | Material of Pole/Trolley | Stainless Steel |
| ACCESSORIES | Number of hooks in the pole | 2, 4 Or higher |
| CONSUMABLES | Number of Breathing circuit (Adult) | Not Provided, 50, 100 Or higher |
| CONSUMABLES | Number of Breathing circuit (Pediatric) | Not Provided, 50, 100 Or higher |
| CONSUMABLES | Number of Humidification Chamber | Not Provided, 50, 100, 200 Or higher |
| CONSUMABLES | Number of Adult Nasal cannula of assorted sizes | Not Provided, 50, 100 Or higher |
| CONSUMABLES | Number of Paediatric Nasal cannula of assorted sizes | Not Provided, 50, 100 Or higher |
| CONSUMABLES | Material of Nasal cannula | Kink proof material and having adhesive wiggle pads to stick on skin care |
| CONSUMABLES | Number of Air filters | Not Provided, 500, 1000, 2000 Or higher |
| ELECTRICAL REQUIREMENTS | Power Source | 230 ± 10 Volts AC / 50 Hz |
| OPERATING ENVIRONMENT | Maximum operating temperature | 10 to 40 Degree Celsius or more |
| OPERATING ENVIRONMENT | Maximum operating relative humidity | 15% to 80% or more |
| CERTIFICATIONS & REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATIONS & REPORTS | Availability of Test Report for each supplied batch/product as per Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Electrical Safety Standards | IEC/EN 60601-1 or equivalent BIS Standard |
| CERTIFICATIONS & REPORTS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes |
| INSTALLATION & TRAINING | Supplier to perform installation, safety and operation checks before handover | Yes |
| INSTALLATION & TRAINING | The supplier/vendor shall provide free of cost training to the personnel in operation | Yes |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 2, 3, 4, 5 Or higher |
| ADDITIONAL REQUIREMENTS | OEM/Reseller shall ensure uninterrupted availability of all spares and components for atleat 5 years from the date of purchase | Yes |
| ADDITIONAL REQUIREMENTS | User/Technical/Operating/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| ADDITIONAL REQUIREMENTS | Product catalog, technical write up in English to be provided both in hard and electronic copies | Yes |
| ADDITIONAL REQUIREMENTS | The Principal Manufacturer must have direct Presence/approved service center In India | Yes |
| ADDITIONAL REQUIREMENTS | Time to provide temporary backup support in case of malfunction/breakdown | within 48 hrs |