diagnostic catheter,tiger catheter,guide wire 0.035,guide wire 0.035,guide wire 0.032,arterial punc
Silchar Medical College And Hospital
CACHAR, ASSAM
Bid Publish Date
27-Feb-2025, 10:43 am
Bid End Date
04-Apr-2025, 9:00 am
EMD
₹10,000
Value
₹46,51,000
Progress
Quantity
2200
Bid Type
Two Packet Bid
All India Institute Of Medical Sciences (aiims) announces a tender for Aortic arterial Perfusion Cannula with flanges, Elongated Aortic arterial Perfusion Cannula Pediatric, Femoral Arterial Perfusion cannula, Femoral Venous Perfusion cannula, Antegrade Aortic Root Cardioplegia Cannula with Vent line, Flexible Silicon antegrade Coronary artery ostial cannula, Rigid antegrade coronary artery ostial cannula, Pericardial Intracardiac Sump catheter, Left Heart Vent Catheter, Cardioplegia delivery system CPDS 4 Ratio 1 type, Custom Tubing Pack- Adult, Custom Tubing Pack- Small Adult, Custom Tubing Pack- Pediatric, Perfusion Connectors- Straight, without luer lock, Perfusion Connectors- straight, with luer lock, Perfusion Connectors- Y-connector, without luer lock, , Central Intravenous Catheter CVP line kit, antibiotic coated. Quantity: 2200. Submission Deadline: 04-04-2025 09: 00: 00. Last date to apply is approaching fast!
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Silchar Medical College And Hospital
CACHAR, ASSAM
N/a
BHOPAL, MADHYA PRADESH
N/a
THANE, MAHARASHTRA
Indian Army
Indian Army
ANANTHNAG, JAMMU & KASHMIR
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Aortic arterial Perfusion Cannula with flanges | Angled (45 deg) wirewound - Overall at least 12 inches with transparent & wirewound body, angled (45 deg) bevelled tip with side holes, tip orientation line and tip guard preferably with vented type connector - SPR, All sizes (16Fr-22Fr) | 250 | nos | dipen.dhabi | 760 |
| 2 | Elongated Aortic arterial Perfusion Cannula Pediatric | With elongated thin walled bevelled tip - vented type - depth markings - overall at least 9 inch long with introducer -SPR,All Sizes (8Fr-14Fr) | 50 | nos | dipen.dhabi | 760 |
| 3 | Femoral Arterial Perfusion cannula | All sized (15Fr-20Fr), Overall length of at least 30 cm with depth marking, introducer, preferably with central lumen & suitable guidewire (.038 inch ) and vented connector - SPR | 30 | nos | dipen.dhabi | 760 |
| 4 | Femoral Venous Perfusion cannula | All sizes (21Fr-24Fr), With multiple side holes, wire wound body, introducer & depth marking preferably with length of at least 50 cm - SPR | 30 | nos | dipen.dhabi | 760 |
| 5 | Antegrade Aortic Root Cardioplegia Cannula with Vent line | Size 5Fr with flanged tip and standard introducer needle, preferably with side holes-SPR | 150 | nos | dipen.dhabi | 760 |
| 6 | Flexible Silicon antegrade Coronary artery ostial cannula | All sizes (12Fr-17Fr), Made of 100% silicon, bulb-shaped tips, and tip 2.1mm, should have male leur lock at the proximal end- SPR | 20 | nos | dipen.dhabi | 760 |
| 7 | Rigid antegrade coronary artery ostial cannula | basket tips, All sizes (10Fr-17Fr) and all angles (45 Degree-90 Degree)- SPR | 20 | nos | dipen.dhabi | 760 |
| 8 | Pericardial Intracardiac Sump catheter | All diameter sizes (12Fr-20Fr) and all lengths (12 Inches-15 Inches), without stainless steel spring,-SPR | 20 | nos | dipen.dhabi | 760 |
| 9 | Left Heart Vent Catheter | All sizes (10Fr-15Fr), 15 inch length, malleable body, vented connector- SPR | 100 | nos | dipen.dhabi | 760 |
| 10 | Cardioplegia delivery system CPDS 4 Ratio 1 type | PV 30ml, Max BFR 2.5 L/min with 3-way with purge line. Preferably with grooved stainless steel HE & 150 m polyester screen filter. Primary Pack should be labelled. Holder to be supplied. SPR | 150 | nos | dipen.dhabi | 760 |
| 11 | Custom Tubing Pack- Adult | Sterile, Disposable, Transparent with or without Arterial filter. Made of PVC/Tygon material. Annexure A | 150 | nos | dipen.dhabi | 760 |
| 12 | Custom Tubing Pack- Small Adult | Sterile, Disposable, Transparent with or without Arterial filter. Made of PVC/Tygon material. Annexure B | 50 | nos | dipen.dhabi | 760 |
| 13 | Custom Tubing Pack- Pediatric | Sterile, Disposable, Transparent with or without Arterial filter. Made of PVC/Tygon material. Annexure C | 30 | nos | dipen.dhabi | 760 |
| 14 | Perfusion Connectors- Straight, without luer lock | Disposable, Sterile, Transparent. Straight and equal, without luer lock, All sizes (1/4 Inches x1/4 Inches to 1/2x1/2 Inches and different comibnations of sizes) | 300 | nos | dipen.dhabi | 760 |
| 15 | Perfusion Connectors- straight, with luer lock | Disposable, Sterile, Transparent. straight and equal, with luer lock, All sizes (1/4 inches x1/ inches to 1/2x1/2 Inches and different combinations of sizes), | 500 | nos | dipen.dhabi | 760 |
| 16 | Perfusion Connectors- Y-connector, without luer lock, | Disposable, Sterile, Transparent. Y-connector, without luer lock, All sizes (1/4 Inches x1/4 Inches x1/4 Inches to 1/2 Inches x1/2 Inches x1/2 Inches and different combinations of sizes) | 300 | nos | dipen.dhabi | 760 |
| 17 | Central Intravenous Catheter CVP line kit, antibiotic coated | Triple lumen,It should have Triple Lumen Catheter Seldinger technique. It should have Lumen Gauge-16G,18G & 18 G and Catheter length 15/20 cm. It should be antibiotic coated (antibacterial/antigungal/silver impregnated). It should have ECG lead and kink proof Nitinol Guide Wire. It should have Introducer Needle with Extra angular port (Valve needle) for insertion of guide wire without removal of syringe., All sizes (5Fr-7Fr) | 50 | nos | dipen.dhabi | 760 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
04-Apr-2025, 9:00 am
Opening Date
04-Apr-2025, 9:30 am
The eligibility requirements include being a registered entity recognized in the medical supply industry. Suppliers must demonstrate relevant certifications, prior experience, and the capacity to deliver the required items. Firms must ensure they meet any technical and financial qualifications specified in the tender documentation to qualify for bidding. It's also crucial for suppliers to adhere to applicable local laws and regulations that govern medical supplies.
The technical specifications outlined in the tender require that all consumables meet high standards of quality and performance. This includes providing details on the materials used, the manufacturing process, and testing certifications to ensure that the products are safe and effective for surgical applications. Compliance with existing medical regulations is mandatory, and thorough documentation supporting these specifications must accompany each bid.
Participants in the tender should be aware of the Earnest Money Deposit (EMD) requirements, which serve as a financial commitment to ensure that suppliers can fulfill their proposed agreements. Additionally, proof of performance security will be required upon contract award, safeguarding against potential non-compliance with the contract terms and ensuring deliveries meet the required standards.
Documentation must be submitted electronically via the designated procurement platform. Accepted formats generally include PDF and Word documents as specified in the tender guidelines. Bidders are advised to ensure all bids include detailed technical and financial information, presented clearly to facilitate the evaluation processes.
Micro, Small, and Medium Enterprises (MSEs) can benefit from provisions aimed at enhancing their participation in this tender. Such benefits may include financial assistance, reduced fees for application processes, and specific incentives linked to the successful delivery of products. Adherence to 'Make in India' policies and local content regulations will also be taken into account, encouraging the support of domestic enterprises.
Sign up now to access all documents
Main Document
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS