Multical System Pack Biochemistry ERBA,Quality Control Solution BIORAD ERBA 360 AM Level 2,Hb 820 R
Indian Air Force
COIMBATORE, TAMIL NADU
Bid Publish Date
12-Feb-2026, 12:48 pm
Bid End Date
05-Mar-2026, 1:00 pm
EMD
₹1,40,000
Value
₹70,00,000
Location
Progress
Quantity
146075
Category
5 Part Automated Hematology Analyser (V2)
Bid Type
Two Packet Bid
Government Medical College And Hospital invites bids for Reagents and consumables for two years, Controls, Low for two years, Controls, Normal for two years, Controls, High for two years, Calibrator for two years, 5 Part Automated Hematology Analyser (V2) (Q2) in CHANDIGARH, CHANDIGARH. Quantity: 146075. Submission Deadline: 05-03-2026 13: 00: 00. Submit your proposal before the deadline.
Main Document
OTHER
OTHER
BOQ
BOQ
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Air Force
COIMBATORE, TAMIL NADU
Indian Army
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Reagents and consumables for two years | CBC + Diff. (200 tests per day) | 146,000 | test | kulbhushan | 730 |
| 2 | Controls, Low for two years | Controls, Low | 24 | vial | kulbhushan | 730 |
| 3 | Controls, Normal for two years | Control, Normal | 24 | vial | kulbhushan | 730 |
| 4 | Controls, High for two years | Control, High | 24 | vial | kulbhushan | 730 |
| 5 | Calibrator for two years | Calibrator | 2 | vial | kulbhushan | 730 |
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | 5 Part Automated Hematology Analyser |
| PRODUCT INFORMATION | Type of Configuration | Benchtop |
| PRODUCT INFORMATION | Type of system offered | Closed system |
| PRODUCT INFORMATION | Type of automation | Fully Automatic |
| PRODUCT INFORMATION | Equipment should have automatic start up,shut down and sample analysis | Yes |
| PRODUCT INFORMATION | Analysis principle | Laser based scatter analysis |
| PRODUCT INFORMATION | Type of cell counting | 5 part WBC differential without Retic and NRBC enumeration capability |
| PRODUCT INFORMATION | Should have multi channel analysis for better resolution and reproductability | Yes |
| PRODUCT INFORMATION | Analysis available | WBC, Lympho#, Lympho%, Neutrophil#, Neutrophil %, Basophil#, Basophil%, Easinophil #, Easinophil%, Monocyte#, Monocyte%, RBC, HGB, MCV, PCV, MCH, MCHC, RDW-SD, RDW CV, PLT, MPV, PDW, PLT, PLCR, PLCC, HCT, PCT, RET#, RET%, NRBC#, WBC, Lympho#, Lympho%, Neutrophil#, Neutrophil %, Basophil#, Basophil%, Easinophil #, Easinophil%, Monocyte#, Monocyte%, RBC, HGB, MCV, PCV, MCH, MCHC, RDW-SD, RDW CV, PLT, MPV, PDW, PLT, PLCR, HCT, PCT |
| PRODUCT INFORMATION | Discrete analysis modes available | CBC,CBC+DIFF |
| PRODUCT INFORMATION | Analysis method for WBC | Tri-angle Laser flow cytometry |
| PRODUCT INFORMATION | Method for platelet measurement | Electrical impedance |
| PRODUCT INFORMATION | RBC Measurement method | Electrical Impedance |
| PRODUCT INFORMATION | Hb measurement | Cyanide free colorimetry |
| PRODUCT INFORMATION | Number of sample racks to cater to different tube sizes | 1 |
| PRODUCT INFORMATION | Maximum sample Aspiration volume needed in all modes | 20µl or less |
| PRODUCT INFORMATION | Minimum sample volume required in all modes | 20µl or less |
| PRODUCT INFORMATION | Throughput capacity in CBC/Differential | 50-60 |
| PRODUCT INFORMATION | Type of modes of sample running | Open vial |
| PRODUCT INFORMATION | Linearity of Platelet | 0 to 3000 * 10 3 cells/ micro litres |
| PRODUCT INFORMATION | RBC Linearity | 0 to 8 x 10^6 per micro litre or more |
| PRODUCT INFORMATION | Hemoglobin linearity | 0 to 25 gm per litre |
| PRODUCT INFORMATION | WBC linearity | 0 to 300 * 1000 cells/ micro litres |
| PRODUCT INFORMATION | Directly measures MCV | Yes |
| PRODUCT INFORMATION | Time taken by the analyser to produce the test results(Analysis time) in seconds | 40-60 |
| PRODUCT INFORMATION | Automatic probe wipe | Yes |
| PRODUCT INFORMATION | Extended Analyses for cytopenic samples | Yes |
| PRODUCT INFORMATION | Quality assurance system with calibration and controls | Yes |
| PRODUCT INFORMATION | Number of quality control programs | Atleast 3 |
| PRODUCT INFORMATION | Type of Calibration | Both manual and automatic |
| PRODUCT INFORMATION | Floating discriminator for platelets and RBC counting for reliable RBC and PLT data | Yes |
| PRODUCT INFORMATION | Separate diluting nozzles for RBC and WBC | Yes |
| PRODUCT INFORMATION | Double bathing mechanism | Yes |
| Data Management and Display | Type of data management | In-built system |
| Data Management and Display | Display | LCD, LED Or higher |
| Data Management and Display | Inbuilt monitor size in inches | >5 |
| Data Management and Display | The processor and RAM of the board system should be latest version | Yes |
| Data Management and Display | HIS/LIS Interface | HL7 |
| Data Management and Display | Type of external storage | USB |
| Data Management and Display | Number of USB Port provided | 4 |
| Data Management and Display | Type of printer unit | External |
| Data Management and Display | Printer type | Thermal printer |
| Data Management and Display | Display and print provided | Scatter plot and histograms |
| Data Management and Display | Auto loader facility | Yes |
| Data Management and Display | Facility for user defined flagging | Yes |
| Data Management and Display | Database capability of storing sets of results and graphics | ≥ 50000 |
| Data Management and Display | L J Plot facility | Yes |
| Data Management and Display | Delta check for cumulative review | Yes |
| Data Management and Display | On-line QC option | Yes |
| Data Management and Display | QC File management | Yes |
| Data Management and Display | Facility for workload recording | Yes |
| Data Management and Display | Ability to transmit results to host computer | Yes |
| Data Management and Display | Type of user Interface or data entry | Touchscreen, Handheld barcode reader facility, Manual |
| Data Management and Display | Have auto cleaning function in the analyser’s software | Yes |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
OTHER
OTHER
BOQ
BOQ
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS