Bid Publish Date
20-Aug-2026, 4:54 pm
Bid End Date
03-Sep-2026, 5:00 pm
Location
Progress
State Forensic Science Laboratory Bhubaneswar invites bids for Non Refrigerated Centrifuge for General Purpose and research (Q3) in KHORDHA, ODISHA. Quantity: 1. Submission Deadline: 03-09-2026 17: 00: 00. Submit your proposal before the deadline.
Quantity
1
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
H1-Highest Priced Bid Elimination
Tech Clarification Time
2 Days
EMD Required
No
MII Purchase Preference
No
MSE Purchase Preference
No
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Past Performance
10 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Non Refrigerated Centrifuge for General Purpose and research (Q3)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
98
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Khordha
Delivery Pincodes
751010
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| SUKANTA KUMAR BEHERA | 751010,AT/POST- RASULGARH, BHUBANESWAR | Khordha | Odisha | 751010 | 1 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC)
Additional Doc 4 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| Performance Parameters | Centrifuge design | Bench Top, Floor Model |
| Performance Parameters | "Number of steps of RPM Variation available in the settings (correspondingly RCF also varies) " | 10, 100 |
| Performance Parameters | RPM setting accuracy | plus minus 5% |
| Performance Parameters | Type of Motor | Brushless(without carbons), With Carbon Brushless |
| Performance Parameters | Type of lid lock | Both Manual and Electronic |
| Performance Parameters | Ambient operating Temperature range in Degree centigrade Celsius and Humidity Range | 0 to 50 and Relative humidity 15 to 90% |
| Performance Parameters | Configuration of Rotor supplied with centrifuge machine | Angle rotor |
| Performance Parameters | Rotor Feature With Reference to Autoclavability | Autoclavable Rotor @121 Degree Celsus |
| Performance Parameters | Size of rotor supplied with centrifuge | "24x15ml(for angle rotor) RPM 6000" |
| Performance Parameters | Maximum RCF | 4650, 4919, 5070 |
| Performance Parameters | Warranty period in years | 5 |
| Material Parameters | Centrifuge Bowl material in Centrifuge | 304 Quality Stainless Steel Moulded |
| Additional Parameters | The Equipment shall be installed and demonstrated before Acceptance | Yes |
| Additional Parameters | Servo Controller Voltage Stabilizer supplied with Item | Yes, No |
| Additional Parameters | Servo stabilizer ratings in KVA | 1, 2, Not Supplied |
| Additional Parameters | Warranty of stabilizer in years | 3, 4, 5, Not supplied |