Portable Ventilators (V2)
Directorate Of Medical Education And Training
MIRZAPUR, UTTAR PRADESH
Bid Publish Date
26-Dec-2025, 11:06 am
Bid End Date
13-Jan-2026, 4:00 pm
EMD
₹2,40,000
Location
Progress
Quantity
6
Bid Type
Two Packet Bid
Hll Lifecare Limited announces a tender for Neonatal Ventilators (Q2) in THIRUVANANTHAPURAM, KERALA. Quantity: 6. Submission Deadline: 13-01-2026 16: 00: 00. Last date to apply is approaching fast!
Directorate Of Medical Education And Training
MIRZAPUR, UTTAR PRADESH
Directorate Of Medical Education And Training
SULTANPUR, UTTAR PRADESH
South East Central Railway
NAGPUR, MAHARASHTRA
Vadodara District Panchayat
N/a
WEST TRIPURA, TRIPURA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| PERFORMANCE PARAMETERS | Patient Type | Neonatal, Premature |
| PERFORMANCE PARAMETERS | Tidal Volume Range In ml | 2 to 300, 2 to 700 |
| PERFORMANCE PARAMETERS | Trigger Sensitivity Mechanism | Pressure, Flow, Pressure and Flow |
| PERFORMANCE PARAMETERS | Flow Pattern/Waveform Adjustment | Yes, No |
| PERFORMANCE PARAMETERS | Sigh Breath Function | Yes, No |
| PERFORMANCE PARAMETERS | Leak Compensation Available | Yes, No |
| PERFORMANCE PARAMETERS | Auto 100% increase O2 Button | Yes, No |
| PERFORMANCE PARAMETERS | Inspiratory Pause Available | Yes, No |
| PERFORMANCE PARAMETERS | Expiratory Hold Available | Yes, No |
| PERFORMANCE PARAMETERS | Suction Control Option Available | Yes, No |
| PERFORMANCE PARAMETERS | Nasal CPAP Option Available | Yes, No |
| PERFORMANCE PARAMETERS | Auto PEEP Manoeuvre | Yes, No |
| PERFORMANCE PARAMETERS | Control Panel Lock | Yes, No |
| PERFORMANCE PARAMETERS | Facility for double lung ventilation | Yes, No |
| PERFORMANCE PARAMETERS | Integrated Air Compressor | Yes, No |
| VENTILATION MODES | PSV(Pressure supported ventilation) | Yes, No |
| VENTILATION MODES | P-CMV(Inspiration pressure control) | Yes, No |
| VENTILATION MODES | PC-AC With Expiratory Minimal volume | Yes, No |
| VENTILATION MODES | SIMV(Synchronized intermittent Mandatory Ventilation) with PCMV | Yes, No |
| VENTILATION MODES | ITT - Inspiratory Time Termination | Yes, No |
| VENTILATION MODES | CPAP:Continuos Positive Airway pressure Ventilation CPAP With backup Ventilation | Yes, No |
| VENTILATION MODES | High Frequency Oscillation Ventilator(HFOV) | Yes, No |
| PATIENT ASSESSMENT TOOLS | Capnography/Co2 Monitoring | Yes, No |
| PATIENT ASSESSMENT TOOLS | Volume Guarantee | Yes, No |
| PATIENT ASSESSMENT TOOLS | APRV | Yes, No |
| PATIENT ASSESSMENT TOOLS | Oxygen Therapy | Yes, No |
| ADDITIONAL CAPABILITIES | ETCO2 Inbuilt available | Yes, No |
| HUMIDIFIER | Disposable Neonatal breathing circuit (dual heated wire) | 20, 50, 80, 100, NA |
| HUMIDIFIER | Auto Feed Humidification chamber Available | Yes, No |
| HUMIDIFIER | Disposable Neonatal breathing circuit with single heated wire provided for inspiratory Limb with Water trap in expiratory limb available | 20, 50, 80, 100, NA |
| ADDITIONAL PARAMETERS | Output Ports Type | HDMI, Ethernet, RJ 45, USB |
| ADDITIONAL PARAMETERS | Remote Alarm Display Port | Yes, No |
| ADDITIONAL PARAMETERS | Reporting (Vent alarms and Patient Status) | Yes, No |
| ADDITIONAL PARAMETERS | View Reports on Display | Yes, No |
| ADDITIONAL PARAMETERS | Save Data to USB | Yes, No |
| ADDITIONAL PARAMETERS | Send Data Via Network | Yes, No |
| ADDITIONAL PARAMETERS | Display Type | LCD/LED/TFT |
| ADDITIONAL PARAMETERS | Display Size in Inches | ≥ 10, ≥ 12, ≥ 15 Or higher |
| ADDITIONAL PARAMETERS | Can be used For Patient Transport | Yes, No |
| ACCESSORIES | Nasal CPAP Kit | 10, 15, 20 |
| ACCESSORIES | Number of Disposable flow sensor | 20, 50, 100, NA if Reusable |
| ACCESSORIES | Number of Reusable flow sensor | 3, 6, NA if Disposable |
| ACCESSORIES | Trolley with ventillator with supporting arm from same manufacturer | Yes, No |
| ACCESSORIES | Autoclavable exhalation valve/expiratory cassette | 2, 3 |
| ACCESSORIES | Test Lung Available | Yes |
| POWER REQUIREMENTS | Operating time of battery in min | 30, 60, 120 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
13-Jan-2026, 4:00 pm
Opening Date
13-Jan-2026, 4:30 pm
Extended Deadline
10-Jan-2026, 4:00 pm
Opening Date
10-Jan-2026, 4:30 pm
Extended Deadline
07-Jan-2026, 4:00 pm
Opening Date
07-Jan-2026, 4:30 pm
Sign up now to access all documents
Main Document
BOQ
CATALOG Specification
ATC