Bid Publish Date
15-Sep-2026, 4:10 pm
Bid End Date
28-Sep-2026, 7:00 pm
EMD
₹6,118
Value
₹6,11,880
Location
Progress
State Bank Of India (sbi) announces a tender for 3. 0 Tr Cassette AC, 1. 5 Tr Split AC, 4. 0 KVA wall mounted stabiliser, 5. 0 KVA wall mounted stabiliser, SITC of cassette AC, SITC of Split AC, copper refrigerant piping, Wire, Drain Pipe, MS Angle, Drain Pump, Reinstallation of old AC in BALLIA, UTTAR PRADESH. Quantity: 295. Submission Deadline: 28-09-2026 19: 00: 00. Last date to apply is approaching fast!
| S.No | Seller | Item | Date | Status |
|---|---|---|---|---|
| 1 | M/S S K COOL SERVICE Under PMA | - | 24-09-2026 17:34:11 | |
| 2 | M/S S.V.REFRIGERATION Under PMA | - | 23-09-2026 17:51:41 | |
| 3 | SAURABH COOLING CORPORATION Under PMA | - | 25-09-2026 00:10:36 | |
| 4 | VEDANTA EQUIPMENTS PRIVATE LIMITED. Under PMA | - | 22-09-2026 18:31:33 | |
| 5 | VS SOLANKI ENTERPRISES Under PMA | - | 25-09-2026 16:15:30 |
| Rank | Seller | Price | Item |
|---|---|---|---|
| L1 | SAURABH COOLING CORPORATION(MII) Under PMA | Item Categories : 3.0 Tr Cassette AC,1.5 Tr Split AC,4.0 KVA wall mounted stabiliser,5.0 KVA wall mounted stabiliser, | |
| L2 | M/S S.V.REFRIGERATION (MII) Under PMA | Item Categories : 3.0 Tr Cassette AC,1.5 Tr Split AC,4.0 KVA wall mounted stabiliser,5.0 KVA wall mounted stabiliser, | |
| L3 | M/S S K COOL SERVICE (MII) Under PMA | Item Categories : 3.0 Tr Cassette AC,1.5 Tr Split AC,4.0 KVA wall mounted stabiliser,5.0 KVA wall mounted stabiliser, |
Quantity
295
Category
3.0 Tr Cassette AC
Bid Type
Two Packet Bid
Bid Validity
30 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Past Performance
80 %
Warranty Period
3 days
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
3.0 Tr Cassette AC , 1.5 Tr Split AC , 4.0 KVA wall mounted stabiliser , 5.0 KVA wall mounted stabiliser , SITC of cassette AC , SITC of Split AC , copper refrigerant piping , Wire , Drain Pipe , MS Angle , Drain Pump , Reinstallation of old AC
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
12
Payment Timelines
Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
20
Delivery Locations
1
Delivery Cities
Ballia
Delivery Pincodes
277001
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Shivam Kumar | 277001,STATE BANK OF INDIA RBO 4 , BALLIA , U.P | Ballia | Uttar Pradesh | 277001 | 3 | 20 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
BOQ
BOQ
GEM_GENERAL_TERMS_AND_CONDITIONS
3.0 Tr Cassette AC
Supply and Installation of ceiling suspended energy efficient 4-way air-flow Cooling type Single phase ONLY 3.0Tr BEE rated (2025-26) 5-Star , inverter Cassett type split air-conditioner inrecessed manner in false ceiling with full function
1.5 Tr Split AC
Supply and Installation of 1.5 TR hi wall type BEE rated (2025)5-Star inverter technology split air conditioner with full function wireless remote and auto restart feature, with indoor/outdoor unit, gas charge, Copper condenser coils and Copper cooling coils company provided copper refrigerant pipe complete in all respects.
4.0 KVA wall mounted stabiliser
Supply & installation of 4.0 KVA (12 AMP), wall mounted stabiliser with TDR (1.5 Split ACs), having Copper winding with voltage range of 130-280V, complete in all respects.
5.0 KVA wall mounted stabiliser
Supply & installation of 5.0 KVA (15 AMP), wall mounted hi lo cut off stabiliser with TDR (For 3.0 TR Cassette ACs), having Copper winding, with voltage range of 130-280V, complete in all respects.
SITC of cassette AC
Installation, testing and commissioning of 3.0 TR cassette type air-conditioner with wall cutting/ mounting including making good of damages complete in all respects.
SITC of Split AC
Installation, testing and commissioning of 1.5 TR Split type air-conditioner with wall cutting/ mounting including making good of damages complete in all respects.
copper refrigerant piping
Supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 3.0 TR cassette AC
copper refrigerant piping
Supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 1.5 TR Split AC
Wire
Supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of 3.0 TR Cassette type AC
Wire
Supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of 1.5 TR Split type AC
Drain Pipe
Supply, installation, testing and commissioning of PVC 25 mm water pipe with accessories (WITH INSULATIONS)
MS Angle
Supply and installation of robust MS angle, MS flat fabricated floor/ wall mounting stand suitable for outdoor units of Cassette/Split ACs,
Drain Pump
Supply & Installation of Drain Pump with water tank (Minimum Water Tank Capacity 200 ml or higher) and level sensor
Reinstallation of old AC
Dismantle, shifting & reinstallation of old existing 2.0/1.5/1.0 Hi-wall split ACs in same premises, gas charging as required, servicing etc., complete in all respect
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | 3.0 Tr Cassette AC | Supply and Installation of ceiling suspended energy efficient 4-way air-flow Cooling type Single phase ONLY 3.0Tr BEE rated (2025-26) 5-Star , inverter Cassett type split air-conditioner inrecessed manner in false ceiling with full function | 3 | nos | sbiro14229.buy_con1 | 20 | |
| 2 | 1.5 Tr Split AC | Supply and Installation of 1.5 TR hi wall type BEE rated (2025)5-Star inverter technology split air conditioner with full function wireless remote and auto restart feature, with indoor/outdoor unit, gas charge, Copper condenser coils and Copper cooling coils company provided copper refrigerant pipe complete in all respects. | 4 | nos | sbiro14229.buy_con1 | 20 | |
| 3 | 4.0 KVA wall mounted stabiliser | Supply & installation of 4.0 KVA (12 AMP), wall mounted stabiliser with TDR (1.5 Split ACs), having Copper winding with voltage range of 130-280V, complete in all respects. | 4 | nos | sbiro14229.buy_con1 | 20 | |
| 4 | 5.0 KVA wall mounted stabiliser | Supply & installation of 5.0 KVA (15 AMP), wall mounted hi lo cut off stabiliser with TDR (For 3.0 TR Cassette ACs), having Copper winding, with voltage range of 130-280V, complete in all respects. | 3 | nos | sbiro14229.buy_con1 | 20 | |
| 5 | SITC of cassette AC | Installation, testing and commissioning of 3.0 TR cassette type air-conditioner with wall cutting/ mounting including making good of damages complete in all respects. | 3 | nos | sbiro14229.buy_con1 | 20 | |
| 6 | SITC of Split AC | Installation, testing and commissioning of 1.5 TR Split type air-conditioner with wall cutting/ mounting including making good of damages complete in all respects. | 4 | nos | sbiro14229.buy_con1 | 20 | |
| 7 | copper refrigerant piping | Supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 3.0 TR cassette AC | 45 | meter | sbiro14229.buy_con1 | 20 | |
| 8 | copper refrigerant piping | Supply, installation, testing and commissioning of insulated copper refrigerant piping set (suction and discharge) duly insulated by nitrile rubber for 1.5 TR Split AC | 50 | meter | sbiro14229.buy_con1 | 20 | |
| 9 | Wire | Supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of 3.0 TR Cassette type AC | 50 | meter | sbiro14229.buy_con1 | 20 | |
| 10 | Wire | Supply, installation, testing and commissioning of inter connecting wiring/ cabling between indoor and outdoor of 1.5 TR Split type AC | 56 | meter | sbiro14229.buy_con1 | 20 | |
| 11 | Drain Pipe | Supply, installation, testing and commissioning of PVC 25 mm water pipe with accessories (WITH INSULATIONS) | 60 | meter | sbiro14229.buy_con1 | 20 | |
| 12 | MS Angle | Supply and installation of robust MS angle, MS flat fabricated floor/ wall mounting stand suitable for outdoor units of Cassette/Split ACs, | 7 | nos | sbiro14229.buy_con1 | 20 | |
| 13 | Drain Pump | Supply & Installation of Drain Pump with water tank (Minimum Water Tank Capacity 200 ml or higher) and level sensor | 4 | nos | sbiro14229.buy_con1 | 20 | |
| 14 | Reinstallation of old AC | Dismantle, shifting & reinstallation of old existing 2.0/1.5/1.0 Hi-wall split ACs in same premises, gas charging as required, servicing etc., complete in all respect | 2 | nos | sbiro14229.buy_con1 | 20 |
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer