TenderDekho Logo
GEM

Tender Notice for Electrocardiography (ECG) Machine (V2) in KACHCHH, GUJARAT

Bid Publish Date

08-Jul-2026, 5:45 pm

Bid End Date

29-Jul-2026, 4:00 pm

Value

₹1,50,000

Progress

Issue08-Jul-2026, 5:45 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 2

Kamdhenu University announces a tender for Electrocardiography (ECG) Machine (V2) (Q2) in KACHCHH, GUJARAT. Quantity: 1. Submission Deadline: 29-07-2026 16: 00: 00. Last date to apply is approaching fast!

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Electrocardiography (ECG) Machine (V2) (Q2)

Authority Records

AGRICULTURE AND CO-OPERATION DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 4

GeM-Bidding-9577795.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Electrocardiography (ECG) Machine (V2)

Gandhinagar District Panchayat

GANDHI NAGAR, GUJARAT

Posted: 29 May 2025
Closed: 13 June 2025
GEM

Electrocardiography (ECG) Machine (V2)

Chittaranjan Locomotive Works

BARDHAMAN, WEST BENGAL

Posted: 23 December 2024
Closed: 2 January 2025
GEM

Electrocardiography (ECG) Machine (V2)

North Eastern Railway

BAREILLY, UTTAR PRADESH

Posted: 21 December 2024
Closed: 31 December 2024
GEM

Electrocardiography (ECG) Machine (V2)

N/a

Posted: 21 December 2024
Closed: 31 December 2024
GEM

Electrocardiography (ECG) Machine (V2)

Government Medical College And Hospital

CHANDIGARH, CHANDIGARH

Posted: 5 December 2024
Closed: 16 December 2024
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
PRODUCT INFORMATION Operating modes of ECG Machine Automatic, Manual and Rhythm
PRODUCT INFORMATION ECG machine should have ECG lead annotation facility Yes
PRODUCT INFORMATION Leads which is in ECG machine should be able to acquire simultaneously and interpret them 12
PRODUCT INFORMATION Number of channels 12 Channel
PRODUCT INFORMATION ECG machine should acquire lead ECG for both adult and pediatric patients Yes
PRODUCT INFORMATION The ECG machine should have facility to show lead fail indication Yes
PRODUCT INFORMATION The ECG machine should have facility to show lead reversal indication Yes
PRODUCT INFORMATION The ECG machine should have facility to show the impedance to quality check of connection Yes
PRODUCT INFORMATION Acquisition time for ECG Machine in sec 10 sec
PRODUCT INFORMATION Digital sampling rate for Pacemaker spike detection 8000 s/sec/channel
PRODUCT INFORMATION Recording of digital sampling for pacemaker 1000 s/sec/channel
PRODUCT INFORMATION ECG machine should have real time colour backlit display of ECG waveforms with signal qualify indication for each lead Yes
PRODUCT INFORMATION ECG machine should have frequency filters Artifact, AC and low and high pass frequency filters
PRODUCT INFORMATION Number of ECGs which can be store in ECG Machine 151 to 200
PRODUCT INFORMATION ECG machine should have full screen preview of ECG report for quality assessment checks prior to print Yes
PRODUCT INFORMATION Type of inbuilt screen LCD
PRODUCT INFORMATION Size of screen in inches 7
PRODUCT INFORMATION Display resolution of ECG machine in pixels 640 x 480
PRODUCT INFORMATION ECG machine should have interpretation facility of the amplitudes, duration and morphologies of ECG waveforms and associated rhythm for adult and pediatric patient Yes
PRODUCT INFORMATION ECG machine should have alphanumeric keyboard for patient data entry Hard keys
PRODUCT INFORMATION System should have the dedicated software to download the ECG form machine in PDF format Yes
PRINTER Printer Type Thermal Printer
PRINTER Recorder Paper Size A5 Size
PRINTER Recorder Speed 25 mm/sec
PRINTER Resolution of digital array printer 200 dpi x 500 dpi
PRINTER Number of Thermal paper 500, 1000 Or higher
PRINTER ECG machine report format Report formats of 3x4, 6x2, Rhythm for up to selected leads, 12 lead extended measurement, 1 minute of continuous waveform data for 1 selected lead
BATTERY Provision of Battery Yes
BATTERY Battery Type Built in Rechargeable Battery
BATTERY Battery capacity of continuous rhythm recording on single charge (minutes) 60
BATTERY Battery capacity 50 ECG or 1 hour of continous rhythm recording on single charge
BATTERY Connectivity to ECG Machine LAN
BATTERY The individual patient lead should be change without replacing the whole patient cable assembly Yes
ENVIRONNMENTS PARAMETERS Operating temperature and humidity Temperature of 10 to 40 degree Celsius and Relative Humidity of 15 to 90%
POWER SUPPLY Power input 220-240 V AC, 50 Hz fitted with Indian plug
ACCESSORIES ECG Machine 12 leads with interpretation 1
ACCESSORIES Chest Electrodes Adult (set of Six) 1
ACCESSORIES Power cable for charging Yes
ACCESSORIES Supplied with Clip electrode Yes
ACCESSORIES Compatible trolley provided Yes
CERTIFICATION & REPORTS Compliance to Medical Device Rules (MDR) 2017 as amended till date Yes
CERTIFICATION & REPORTS Manufacturing unit certification ISO:13485 (Latest)
CERTIFICATION & REPORTS Availability of Test Report for each supplied batch/product as per Medical Device Rules (MDR) 2017 as amended till date Yes
CERTIFICATION & REPORTS Compliance to Safety Standards IS 13450:Part 2:Sec 25 / IEC 60601-2-25
CERTIFICATION & REPORTS Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement Yes
WARRANTY Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 5 Or higher
Miscellaneous Parameters User/Technical/Maintenance manuals to be supplied in English in hard and soft copy Yes
Miscellaneous Parameters The Principal Manufacturer must have direct Presence/approved service center In India Yes
Miscellaneous Parameters Installation and demonstration of equipment and training to be provided after completing supplies before acceptance Yes

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC)

8

Additional Doc 2 (Requested in ATC)

9

Additional Doc 3 (Requested in ATC)

10

Additional Doc 4 (Requested in ATC)

11

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

12

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found
Urgent

Electrocardiography (ECG) Machine (V2)

Kachchh District Panchayat

📍 KACHCHH, GUJARAT

EMD: ₹60,000
Est: ₹20.0 L
⏰ Deadline: 6 days left
🛒 Type: Goods
View GEM
Urgent

Electrocardiography (ECG) Machine (V2)

N/a

📍 MUMBAI, MAHARASHTRA

EMD: ₹24,000
⏰ Deadline: 5 days left
🛒 Type: Goods
View GEM

Electrocardiography (ECG) Machine (V2)

Border Security Force (bsf)

📍 MALKANGIRI, ODISHA

⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Electrocardiography (ECG) Machine (V2)

All India Institute Of Medical Sciences (aiims)

📍 JODHPUR, RAJASTHAN

EMD: ₹38,000
⏰ Deadline: 3 weeks left
🛒 Type: Goods
View GEM

Electrocardiography (ECG) Machine (V2)

South Western Railway

⏰ Deadline: 2 weeks left
🛒 Type: Goods
View GEM