TenderDekho Logo
Active GEM

Procurement Opportunity: SPECTROPHOTOMETER in BHIWANI, HARYANA

Bid Publish Date

21-Jul-2026, 4:20 pm

Bid End Date

11-Aug-2026, 5:00 pm

EMD

₹11,990

Progress

Issue21-Jul-2026, 4:20 pm
AwardPending
Explore all 6 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 18

Chaudhary Bansi Lal University Bhiwani invites bids for SPECTROPHOTOMETER (Q2) in BHIWANI, HARYANA. Quantity: 1. Submission Deadline: 11-08-2026 17: 00: 00. Submit your proposal before the deadline.

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

No

Item Category

SPECTROPHOTOMETER (Q2)

Advisory Bank

State Bank of India

ePBG Percentage

0.01%

ePBG Duration (Months)

14

Payment Timelines

Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)

Delivery Details

Max Delivery Days

45

Delivery Locations

1

Delivery Cities

Bhiwani

Delivery Pincodes

127021

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Lalita Gupta127021,Chaudhary Bansi Lal UniversityBhiwaniHaryana127021145-

Authority Records

HIGHER EDUCATION DEPARTMENT

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 3

GeM-Bidding-9639689.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
LIGHT SOURCE Light Source Xenon Flash
LIGHT SOURCE Diffraction Grating (lines/mm) 600
LIGHT SOURCE Switching of Light Source Automatic
LIGHT SOURCE Wavelength Setting And Scanning Mannual
TYPE Type of Spectrophotometer UV - VISIBLE
TYPE Type of Optical System Single Beam
TYPE Monochromator Type NA
TYPE Detector Type CMOS
TYPE Spectral Bandwidth Type Fixed Bandwidth
OPTICAL PERFORMANCE Source Wavelength - Minimum 190.0
OPTICAL PERFORMANCE Source Wavelength - Maximum 320, 340, 760, 780, 900, 960, 1000, 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650, 644 Or higher
OPTICAL PERFORMANCE Resolution 0.002
OPTICAL PERFORMANCE Wavelength Accuracy (+/-) 1.0
OPTICAL PERFORMANCE Bandwidth (nm) 5.0
OPTICAL PERFORMANCE If variable band width, Specify the incremental step value(mm) 1.0, NA
OPTICAL PERFORMANCE Scanning Speed (nm/min) 5000
OPTICAL PERFORMANCE Focal length (mm) 0 to 49
OPTICAL PERFORMANCE Photometric measurement modes Transmittance, Absorbance, Concentration (Wavelength, time)
OPTICAL PERFORMANCE Photometric Absorbance (Max) (Abs) (+/-) 8
OPTICAL PERFORMANCE Photometric Absorbance Accuracy (Max) (+/-) 0.001 - 0.003 Or lower
OPTICAL PERFORMANCE Photometric Transmittance (Max) (+/-) 100.0
OPTICAL PERFORMANCE Photometric Transmittance Accuracy (Max) (+/-) 0.0 - 0.5 Or lower
OPTICAL PERFORMANCE Photometric Reflectance (Max) (+/-) 0.0
OPTICAL PERFORMANCE Photometric Reflectance Accuracy (Max) (+/-) 0.0 - 0.0 Or lower
OPTICAL PERFORMANCE Stray Light Correction Automatic
OPTICAL PERFORMANCE Baseline Correction Automatic
GENERIC Display In-built display
GENERIC Display type LCD with Backlight
GENERIC Display Size 5.0 - 30.0 Or higher
GENERIC Test result printing Through external printer
GENERIC If inbuilt printer, Type of printer N/A
GENERIC Suitable software for connecting PC & Printer N/A
GENERIC Connectivity USB
GENERIC Internal storage(GB) 8.0 - 80.0 Or higher
GENERIC Sample switching/selection Manual
GENERIC Capacity of Sample holder / Sample Carousel 1
GENERIC Mximum Path Length of sample 0.5
GENERIC Number of Cuvettes supplied-inclusive in the scope of supply 0
GENERIC Power Supply 230 V ± 10, 50 Hz
GENERIC Spares and Consumables inclusive in the scope of supply Yes
OPERATING CONDITIONS Minimum Operating Temperature 10.0
OPERATING CONDITIONS Maximum Operating Temperature 40.0
OPERATING CONDITIONS Operating Humidity (RH) (%) at 40 degree C 80.0
WARRANTY Onsite Warranty 1.0
WARRANTY Availability of Spares (at extra cost) 7.0
Certification Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements No
Certification Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use No
Certification Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification No
Certification If yes test report to furnished,to the buyer on demand N/A

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer