Chaudhary Bansi Lal University Bhiwani invites bids for SPECTROPHOTOMETER (Q2) in BHIWANI, HARYANA. Quantity: 1. Submission Deadline: 11-08-2026 17: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
SPECTROPHOTOMETER (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
0.01%
ePBG Duration (Months)
14
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
45
Delivery Locations
1
Delivery Cities
Bhiwani
Delivery Pincodes
127021
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Lalita Gupta | 127021,Chaudhary Bansi Lal University | Bhiwani | Haryana | 127021 | 1 | 45 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
| Category | Specification | Requirement |
|---|---|---|
| LIGHT SOURCE | Light Source | Xenon Flash |
| LIGHT SOURCE | Diffraction Grating (lines/mm) | 600 |
| LIGHT SOURCE | Switching of Light Source | Automatic |
| LIGHT SOURCE | Wavelength Setting And Scanning | Mannual |
| TYPE | Type of Spectrophotometer | UV - VISIBLE |
| TYPE | Type of Optical System | Single Beam |
| TYPE | Monochromator Type | NA |
| TYPE | Detector Type | CMOS |
| TYPE | Spectral Bandwidth Type | Fixed Bandwidth |
| OPTICAL PERFORMANCE | Source Wavelength - Minimum | 190.0 |
| OPTICAL PERFORMANCE | Source Wavelength - Maximum | 320, 340, 760, 780, 900, 960, 1000, 1100, 1500, 2000, 2500, 2700, 3000, 3200, 3300, 1650, 644 Or higher |
| OPTICAL PERFORMANCE | Resolution | 0.002 |
| OPTICAL PERFORMANCE | Wavelength Accuracy (+/-) | 1.0 |
| OPTICAL PERFORMANCE | Bandwidth (nm) | 5.0 |
| OPTICAL PERFORMANCE | If variable band width, Specify the incremental step value(mm) | 1.0, NA |
| OPTICAL PERFORMANCE | Scanning Speed (nm/min) | 5000 |
| OPTICAL PERFORMANCE | Focal length (mm) | 0 to 49 |
| OPTICAL PERFORMANCE | Photometric measurement modes | Transmittance, Absorbance, Concentration (Wavelength, time) |
| OPTICAL PERFORMANCE | Photometric Absorbance (Max) (Abs) (+/-) | 8 |
| OPTICAL PERFORMANCE | Photometric Absorbance Accuracy (Max) (+/-) | 0.001 - 0.003 Or lower |
| OPTICAL PERFORMANCE | Photometric Transmittance (Max) (+/-) | 100.0 |
| OPTICAL PERFORMANCE | Photometric Transmittance Accuracy (Max) (+/-) | 0.0 - 0.5 Or lower |
| OPTICAL PERFORMANCE | Photometric Reflectance (Max) (+/-) | 0.0 |
| OPTICAL PERFORMANCE | Photometric Reflectance Accuracy (Max) (+/-) | 0.0 - 0.0 Or lower |
| OPTICAL PERFORMANCE | Stray Light Correction | Automatic |
| OPTICAL PERFORMANCE | Baseline Correction | Automatic |
| GENERIC | Display | In-built display |
| GENERIC | Display type | LCD with Backlight |
| GENERIC | Display Size | 5.0 - 30.0 Or higher |
| GENERIC | Test result printing | Through external printer |
| GENERIC | If inbuilt printer, Type of printer | N/A |
| GENERIC | Suitable software for connecting PC & Printer | N/A |
| GENERIC | Connectivity | USB |
| GENERIC | Internal storage(GB) | 8.0 - 80.0 Or higher |
| GENERIC | Sample switching/selection | Manual |
| GENERIC | Capacity of Sample holder / Sample Carousel | 1 |
| GENERIC | Mximum Path Length of sample | 0.5 |
| GENERIC | Number of Cuvettes supplied-inclusive in the scope of supply | 0 |
| GENERIC | Power Supply | 230 V ± 10, 50 Hz |
| GENERIC | Spares and Consumables inclusive in the scope of supply | Yes |
| OPERATING CONDITIONS | Minimum Operating Temperature | 10.0 |
| OPERATING CONDITIONS | Maximum Operating Temperature | 40.0 |
| OPERATING CONDITIONS | Operating Humidity (RH) (%) at 40 degree C | 80.0 |
| WARRANTY | Onsite Warranty | 1.0 |
| WARRANTY | Availability of Spares (at extra cost) | 7.0 |
| Certification | Availability of UL/CE Certification as per EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control, and laboratory use General requirements | No |
| Certification | Conformance to EMC/EMI as per EN 61326-1:2013 Electrical equipment for measurement, control and laboratory use | No |
| Certification | Availability of Test Reports from Central Govt / NABL approved / ILAC acredited lab to prove conformity to the specification | No |
| Certification | If yes test report to furnished,to the buyer on demand | N/A |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS