TenderDekho Logo
Active GEM

Invitation to Bid - Spectrum Analyzers and Vector Network Analyzers

Bid Publish Date

27-Aug-2026, 10:22 am

Bid End Date

10-Sep-2026, 3:00 pm

EMD

₹60,000

Progress

Issue27-Aug-2026, 10:22 am
AwardPending

Directorate Of Purchase And Stores invites bids for Spectrum Analyzers and Vector Network Analyzers (Q3). Quantity: 1. Submission Deadline: 10-09-2026 15: 00: 00. Submit your proposal before the deadline.

Tender Data

Bid Details

Quantity

1

Bid Type

Two Packet Bid

Bid Validity

120 (Days)

Bid Type

Service

Evaluation

Total value wise evaluation

Inspection Required

No

RA Qualification Rule

H1-Highest Priced Bid Elimination

Tech Clarification Time

3 Days

Preference & Exemptions

EMD Required

Yes

MII Purchase Preference

No

MSE Purchase Preference

Yes

MSE Preference Band

L1+15%

MSE Exemption/Relaxation

Yes

Startup Exemption/Relaxation

Yes

Bid Splitting Applied

No

Requirements

Warranty Period

3 years

Arbitration Clause

No

Mediation Clause

No

Additional Tender Data

Commercial Details

Tender Category

Goods

Bid To RA

No

Bid To RA Enabled

Yes

Item Category

Spectrum Analyzers and Vector Network Analyzers (Q3)

Advisory Bank

State Bank of India

ePBG Percentage

5%

ePBG Duration (Months)

42

Delivery Details

Max Delivery Days

120

Delivery Locations

1

Delivery Cities

24 Paraganas North

Delivery Pincodes

700064

Delivery Locations

ConsigneeAddressCityStatePincodeQuantityDelivery DaysAdditional Requirement
Abhijit Das700064,VARIABLE ENERGY CYCLOTRON CENTRE I/AF BIDHAN NAGAR KOLKATA24 Paraganas NorthWest Bengal7000641120-

Authority Records

DEPARTMENT OF ATOMIC ENERGY

BID & GeM Expert Consultancy

End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.

Bid Preparation GeM Registration Document Filing

Free consultation · 24h response

Documents 5

GeM-Bidding-9746663.pdf

Main Document

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Authority & Contact

Office Name

Directorate Of Purchase And Stores

Ministry

PMO

Grievance Contact

[email protected]

Categories 2

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

2

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
FEATURES Description of the itemuu Two port vector network analyzers (without spectrum analyser)
GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers NA
GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Trigger NA
GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Display TFT Colour display
GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Interface USB, LAN
GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Software for transfer of screen shot/measurement data to PC NA
SPECTRUM ANALYZER FEATURES Frequency Range NA
SPECTRUM ANALYZER FEATURES Aging rate of spectrum analyzer frequency: Better than 1x10-6 /Year NA
SPECTRUM ANALYZER FEATURES Frequency counter Resolution(minimum) (Hz) NA
SPECTRUM ANALYZER FEATURES Frequency Span NA
SPECTRUM ANALYZER FEATURES Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz NA
SPECTRUM ANALYZER FEATURES Spectral purity:Harmonics @ -40dBm level <=60 dBc NA
SPECTRUM ANALYZER FEATURES Sweep time @span >or= 1 KHz NA
SPECTRUM ANALYZER FEATURES Sweep time @span = 0 Hz NA
SPECTRUM ANALYZER FEATURES Resolution Bandwidth (-3dB) NA
SPECTRUM ANALYZER FEATURES Video Bandwidth NA
SPECTRUM ANALYZER FEATURES Amplitude : Max input level for protection (dBm) NA
SPECTRUM ANALYZER FEATURES Amplitude : Max input level for measurement (dBm) NA
SPECTRUM ANALYZER FEATURES Amplitude :level measurement uncertainity (dB) NA
SPECTRUM ANALYZER FEATURES Average noise level displayed(@300HzRBW,10Hz VBW) NA
SPECTRUM ANALYZER FEATURES Average noise level displayed(@100HzRBW,1Hz VBW) NA
SPECTRUM ANALYZER FEATURES Average noise level displayed(@300HzRBW,1Hz VBW) NA
SPECTRUM ANALYZER FEATURES Measurement features NA
VECTOR NETWORK ANALYZER FEATURES Frequency Resolution (CW ON) (Hz) 1Hz
VECTOR NETWORK ANALYZER FEATURES Return Loss (dB) 0.00 to 60
VECTOR NETWORK ANALYZER FEATURES VSWR (dB) 1.01 to 10.00
VECTOR NETWORK ANALYZER FEATURES Cable Loss (dB) 0.00 to 30.00
VECTOR NETWORK ANALYZER FEATURES Calibration with Precision calibration components-open, short, load should be included to achieve directivity >35 dB hint: NA for items designated as spectrum analyzers Yes
VECTOR NETWORK ANALYZER FEATURES Abilty to locate Distance-to-fault in Co-axial cables yes
VECTOR NETWORK ANALYZER FEATURES Phase Range (degree) -180 to +180
VECTOR NETWORK ANALYZER FEATURES Phase Resolution (deg) 0.01
VECTOR NETWORK ANALYZER FEATURES RF output port Yes
VECTOR NETWORK ANALYZER FEATURES Dynamic Range 90
VECTOR NETWORK ANALYZER FEATURES Nominal port power output: Hi Power/Lo-Power selectable yes
VECTOR NETWORK ANALYZER FEATURES Measurement of S11 and S21 and Smith Chart Yes
VECTOR NETWORK ANALYZER FEATURES Vector Voltmeter for comparision and verification of the phase of the phase-matched cables NA
OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C
OPERATING CONDITIONS Operating Humidity 80% RH @ 40 degree C
POWER REQUIREMENT Power requirement 230 +- 10 VAC, 50Hz
POWER REQUIREMENT chemistry of the battery NA
POWER REQUIREMENT Suitable charger / adaptor provided NA
WARRANTY Warranty 3, 4, 5 Or higher
CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes
CERTIFICATION/TEST REPORT DETAILS conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:9000/part-3/section-5/1977 latest no
CERTIFICATION/TEST REPORT DETAILS conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:9000/part-2/section-4/1977 latest no
CERTIFICATION/TEST REPORT DETAILS conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no
CERTIFICATION/TEST REPORT DETAILS Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification No

Explore More Opportunities

Quick Access