Holter Monitor (V2)
Directorate Of Medical Education And Training
GHAZIPUR, UTTAR PRADESH
Progress
Quantity
1
Bid Type
Two Packet Bid
N/a invites bids for Holter Monitor (V2) (Q2) in EAST DELHI, DELHI. Quantity: 1. Submission Deadline: 07-07-2026 17: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Holter Monitor (V2) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Directorate Of Medical Education And Training
GHAZIPUR, UTTAR PRADESH
Indian Army
JAMMU, JAMMU & KASHMIR
National Institute Of Mental Health And Neuro Sciences (nimhans)
BANGALORE, KARNATAKA
Indian Army
JHANSI, UTTAR PRADESH
Hll Infra Tech Services Limited
GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Name | Holter Monitor |
| PRODUCT INFORMATION | Type | Worn in a case on a belt |
| PRODUCT INFORMATION | Number of Channels | 12 |
| PRODUCT INFORMATION | Number of Leads | 10 |
| PRODUCT INFORMATION | Analyzing Various Arrhythmias | Ventricular Ectopics, Supraventricular Ectopics, Ventricular Tachycardia, Ventricular Fibrillation, Supraventricular Tachycardia, Atrial Fibrillation, Sinus Pause |
| PRODUCT INFORMATION | Full Disclosure of ECG with Different Color Coding for | VE, SVE and Pauses |
| PRODUCT INFORMATION | Hourly Count Menu (Minimum) | Two Scan |
| PRODUCT INFORMATION | Minimum Templates Editing to Analyse VE, SVE, V-RUN,SV-RUN, PAUSE, ST, etc | 20 Templates |
| PRODUCT INFORMATION | Atrial Fibrillation/Flutter analysis | Yes |
| PRODUCT INFORMATION | Heart rate variability (HRV) analysis | Yes |
| PRODUCT INFORMATION | SAECG-Late potential analysis | No |
| PRODUCT INFORMATION | Pace Maker auto detection and analysis | Yes |
| PRODUCT INFORMATION | 12 Lead ST Scan | Yes |
| PRODUCT INFORMATION | QT analysis with validation | Yes |
| PRODUCT INFORMATION | To print ECG strips from any part of Holter recording | Yes |
| PRODUCT INFORMATION | T Wave altemans | No |
| PRODUCT INFORMATION | Facility for electronic compact technique for Flash card/USB Cable | Yes |
| PRODUCT INFORMATION | Should be able to edit and reclassify beats and arrhythmias | Yes |
| PRODUCT INFORMATION | Indication for Data Storage and Device Status | LED |
| PRODUCT INFORMATION | Sleep Apnea Analysis | No |
| PRODUCT INFORMATION | Real time ST analysis | Yes |
| PRODUCT INFORMATION | ST profile, ST elevation, ST depression, Heart rate, Mets, NIBP, ST index should be able to be clearly analyze | Yes |
| PRODUCT INFORMATION | System should have automatic arythmia detection | Yes |
| PRODUCT INFORMATION | System should present comprehensive final report on minute by minute record of ST segment trend | Yes |
| PRODUCT INFORMATION | System should have facility to do re-analysis of stored ECG by changing line measurement point title ST and J | Yes |
| PRODUCT INFORMATION | Real time average complexes | Yes |
| PRODUCT INFORMATION | Standard Leads Cables Set provided | Yes |
| PRODUCT INFORMATION | ST segment analysis should be available for all selected channels | Yes |
| RECORDER CONFIGURATION | Recorder should be minimum 3 channel ECG for recording data duration | 24 Hrs, 48 Hrs, 72 Hrs |
| RECORDER CONFIGURATION | Digital Recorder with removable storage media | Yes |
| RECORDER CONFIGURATION | Memory storage capacity of Card | 4GB, 32GB |
| RECORDER CONFIGURATION | Number of Hours Store ECG into Flash Memory Card/Inbuilt Memory | 24 or 48 Hours |
| RECORDER CONFIGURATION | Saved data should be accessed using an integrated reading device | Yes |
| RECORDER CONFIGURATION | Compatibility with Alkaline Battery | Yes |
| RECORDER CONFIGURATION | Pacemaker spike detection | Minimum 512 samples/sec/ Channel |
| RECORDER CONFIGURATION | Recording and Storage | Minimum 128 samples/sec/Channel |
| RECORDER CONFIGURATION | Venticular Late Potential (VLP) | Minimum 1000 samples/sec/Channel |
| DATA MANAGEMENT SYSTEM | Computer system with latest licensed operating system and antivirus provided | Yes |
| DATA MANAGEMENT SYSTEM | PC monitor type | LCD/LED |
| DATA MANAGEMENT SYSTEM | Software | Holter analysis, Trends, Strips, Page, QT Analysis, Shape, Event Review, Episode Review , Final Report, TWA Alterns Analysis |
| DATA MANAGEMENT SYSTEM | Minimum size for color PC monitor (inches) | 17 inch or more |
| DATA MANAGEMENT SYSTEM | Printer | Colour Laser Printer, Black and White Laser Printer |
| DATA MANAGEMENT SYSTEM | UPS with power backup (Minutes) | 30, NA if not provided |
| REPORT FORMAT | Format for reporting Patient information | Indications, medications, symptoms, time, diagnosis, notes and conclusions with space for personnel and physician electronic signature. |
| REPORT FORMAT | Format for Examination summery | Quality of recording, baseline rhythm, min and max heart rate, VE, SVE, VT, SVT, Blocks and Pauses |
| REPORT FORMAT | Report format | Covering page, Arrhythmia analysis report, ST segment analysis, Automatically and manually selected ECG strips |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 1, 5 |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | YES |
| CERTIFICATIONS | Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for product as per Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
07-Jul-2026, 5:00 pm
Opening Date
07-Jul-2026, 5:30 pm
Sanjay Gandhi Post Graduate Institute Of Medical Sciences Lucknow
📍 LUCKNOW, UTTAR PRADESH
N/a
📍 THIRUVANANTHAPURAM, KERALA
Hqids
📍 NEW DELHI, DELHI
Kolkata Police
📍 KOLKATA, WEST BENGAL
Dg Armed Forces Medical Service
📍 JAIPUR, RAJASTHAN
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS