Annual preventive maintenance Repair and operations,Provision of additional man hour,Provision of a
Airports Authority Of India
VADODARA, GUJARAT
Progress
Quantity
1205
Bid Type
Two Packet Bid
Bharat Sanchar Nigam Limited Portal(bsnl) invites bids for Inspection Testing Checking, Attending break down faults, Repairing of 11 KV GOAB, Replacement faulty transformer, Painting the entire transformer body, Supply aluminum armoured power cable, Laying of XLPE power cable, Supplying and making end termination, Providing and fixing 6 SWG dia GI wire, Earthing with GI earth pipe, Providing and laying earth connection in KAMRUP, ASSAM. Quantity: 1205. Submission Deadline: 24-05-2025 11: 00: 00. Submit your proposal before the deadline.
Main Document
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Airports Authority Of India
VADODARA, GUJARAT
Bharat Sanchar Nigam Limited Portal(bsnl)
HYDERABAD, TELANGANA
Bharat Sanchar Nigam Limited Portal(bsnl)
PATNA, BIHAR
Bharat Sanchar Nigam Limited Portal(bsnl)
MUZAFFARPUR, BIHAR
Bharat Sanchar Nigam Limited Portal(bsnl)
MUZAFFARPUR, BIHAR
Tender Results
Loading results...
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) |
|---|---|---|---|---|---|---|
| 1 | Inspection Testing Checking | Up to 315 KVA transformer of 11KV by 415 V | 30 | jobs | sde_elec_jrt | 365 |
| 2 | Attending break down faults | Supplying and erection of three piece nonlinear resistor type lightning arrestor | 5 | sets | sde_elec_jrt | 365 |
| 3 | Attending break down faults | ACSR Weasel Approx length 1mtr with suitable Alu Lug and socket | 5 | nos | sde_elec_jrt | 365 |
| 4 | Attending break down faults | Supplying and erection of 11 KV pin insulator complete with large steel head GI pin | 12 | sets | sde_elec_jrt | 365 |
| 5 | Attending break down faults | Supplying and erection of 11 KV disc insulator for 11 KV over head lines | 12 | nos | sde_elec_jrt | 365 |
| 6 | Attending break down faults | Silicagel breather of 150 gm capacity | 6 | nos | sde_elec_jrt | 365 |
| 7 | Attending break down faults | 11 KV air break Gang operated switch 200Amp with 06 nuts bolts connector | 5 | sets | sde_elec_jrt | 365 |
| 8 | Attending break down faults | 11 KV DOLO fuse with its barrel assembly | 5 | sets | sde_elec_jrt | 365 |
| 9 | Attending break down faults | Transformer oil HV grade with suitable dielectric strength | 400 | ltrs | sde_elec_jrt | 365 |
| 10 | Attending break down faults | Filteration of existing low BDV transformer oil | 300 | ltrs | sde_elec_jrt | 365 |
| 11 | Attending break down faults | 63 amp 415 V TPN FSU with 63 amp HRC fuses in open execution | 3 | nos | sde_elec_jrt | 365 |
| 12 | Attending break down faults | 100A 4 pole 415V 50 Hz MCCB with thermal release range 32A to 40A | 5 | nos | sde_elec_jrt | 365 |
| 13 | Attending break down faults | 100A 4 pole 415V 50 Hz MCCB with thermal release range 50A to 63A | 5 | nos | sde_elec_jrt | 365 |
| 14 | Repairing of 11 KV GOAB | Repairing of 11 KV gang operated air break switch DO fuse | 8 | jobs | sde_elec_jrt | 365 |
| 15 | Replacement faulty transformer | 25 KVA Aluminium wound 11KV by 415 V | 10 | jobs | sde_elec_jrt | 365 |
| 16 | Replacement faulty transformer | 25 KVA Copper wound 11KV by 415 V | 2 | nos | sde_elec_jrt | 365 |
| 17 | Replacement faulty transformer | 63 KVA Aluminium wound 11KV by 415 V | 4 | nos | sde_elec_jrt | 365 |
| 18 | Replacement faulty transformer | 63 KVA Copper wound 11KV by 415 V | 1 | nos | sde_elec_jrt | 365 |
| 19 | Painting the entire transformer body | with two coats of primer and two coats of water proof synthetic enamel paint | 10 | job | sde_elec_jrt | 365 |
| 20 | Supply aluminum armoured power cable | 3.5x25sqmm of 1.1KV grade | 30 | mtrs | sde_elec_jrt | 365 |
| 21 | Supply aluminum armoured power cable | 3.5x50sqmm of 1.1KV grade | 20 | mtrs | sde_elec_jrt | 365 |
| 22 | Laying of XLPE power cable | Upto 35 sq mm in ground including excavation sand cushioning protective covering | 20 | mtrs | sde_elec_jrt | 365 |
| 23 | Laying of XLPE power cable | above 35sqmm and upto 95 sq mm in ground including excavation sand cushioning protective covering | 10 | mtrs | sde_elec_jrt | 365 |
| 24 | Laying of XLPE power cable | Upto 35 sq mm of 1.1 KV grade in the existing RCC or HUME or METAL pipe | 5 | mtrs | sde_elec_jrt | 365 |
| 25 | Laying of XLPE power cable | above 35sqmm and upto 95 sq mm of 1.1 KV grade in the existing RCC or HUME or METAL pipe | 5 | mtrs | sde_elec_jrt | 365 |
| 26 | Laying of XLPE power cable | Upto 35 sq mm of 1.1 KV grade in the existing masonry open duct | 2 | mtrs | sde_elec_jrt | 365 |
| 27 | Laying of XLPE power cable | above 35sqmm and upto 95 sq mm of 1.1 KV grade in the existing masonry open duct | 2 | mtrs | sde_elec_jrt | 365 |
| 28 | Laying of XLPE power cable | Upto 35 sq mm of 1.1 KV grade on wall surface | 3 | mtrs | sde_elec_jrt | 365 |
| 29 | Laying of XLPE power cable | above 35sqmm and upto 95 sq mm of 1.1 KV grade on wall surface | 3 | mtrs | sde_elec_jrt | 365 |
| 30 | Supplying and making end termination | 3.5x25 sqmm of 1.1 KV grade | 6 | sets | sde_elec_jrt | 365 |
| 31 | Supplying and making end termination | 3.5x50 sqmm of 1.1 KV grade | 6 | sets | sde_elec_jrt | 365 |
| 32 | Providing and fixing 6 SWG dia GI wire | on surface or in recess for loop earthing along with existing cable | 100 | mtrs | sde_elec_jrt | 365 |
| 33 | Earthing with GI earth pipe | 4.5 metre long, 40 mm dia including accessories, watering pipe etc. with charcoal/ coke and salt | 15 | sets | sde_elec_jrt | 365 |
| 34 | Providing and laying earth connection | from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe | 150 | mtrs | sde_elec_jrt | 365 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Key insights about ASSAM tender market
The eligibility requirements include being a registered entity within the construction or electrical services sector. Bidders must possess valid licenses and should demonstrate prior experience in similar projects, particularly in conducting transformer repair works. Furthermore, bidders must comply with regulatory safety standards and show evidence of financial stability.
Bidders are required to comply with specific technical specifications such as the capability to repair 11 KV GOAB transformers and to supply aluminum armored power cables. Additionally, expertise in the installation and laying of XLPE power cables is essential, along with adherence to local electrical safety standards to ensure compliance with necessary regulations.
Payment terms will typically include provisions for an Earnest Money Deposit (EMD), which must be submitted along with the proposal to demonstrate financial commitment. Upon contract award, the successful bidder may be required to furnish a performance security which will be released upon the satisfactory completion of the project as per the outlined terms of the contract.
Bids must be submitted electronically through the designated portal. All documents should be prepared in accepted formats, such as PDF or Word. Ensure compliance with the submission guidelines provided in the tender documents to avoid disqualification due to format issues.
Micro, Small, and Medium Enterprises (MSEs) will benefit from specific provisions aimed at fostering participation, including reduced financial guarantees and simplified qualification criteria. The government encourages MSE engagement in public sector contracts to boost local economies and innovation, thus aligning with the broader Make in India initiatives.