Bid Publish Date
07-Aug-2026, 11:57 am
Bid End Date
31-Aug-2026, 12:00 pm
EMD
₹44,250
Value
₹14,75,000
Location
Progress
Kamdhenu University invites bids for Veterinary Hematology Analyzer (V2) (Q2) in BANASKANTHA, GUJARAT. Quantity: 3. Submission Deadline: 31-08-2026 12: 00: 00. Submit your proposal before the deadline.
Quantity
3
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
RA Qualification Rule
50% Lowest Priced Technically Qualified Bidders
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
Yes
MII Preference Band
L1+20%
MSE Purchase Preference
Yes
MSE Preference Band
L1+20%
MSE Exemption/Relaxation
Yes
Startup Exemption/Relaxation
Yes
Bid Splitting Applied
No
Min. Avg. Annual Turnover
7
OEM Avg. Turnover
14
Past Performance
50 %
Experience Required
3 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Veterinary Hematology Analyzer (V2) (Q2)
Advisory Bank
State Bank of India
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Pre-Bid Date
18-08-2026 11:00:00
Pre-Bid Venue
Dept. of Veterinary Physiology, Veterinary college, Sardarkrushinagar- 385506
Max Delivery Days
15
Delivery Locations
3
Delivery Cities
Banas Kantha
Delivery Pincodes
385506
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Dr. Priti Dilipsinh Vihol | 385506,Sardarkrushinagar, Dantiwada, Gujarat 385506 | Banas Kantha | Gujarat | 385506 | 1 | 15 | - |
| Jigneshkumar Manilal Patel | 385506,Sardarkrushinagar, Dantiwada, Gujarat 385506 | Banas Kantha | Gujarat | 385506 | 1 | 15 | - |
| Patel Pankajkumar Ashokbhai | 385506,Sardarkrushinagar, Dantiwada, Gujarat 385506 | Banas Kantha | Gujarat | 385506 | 1 | 15 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Extended Deadline
31-Aug-2026, 6:30 am
Opening Date
31-Aug-2026, 7:00 am
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| GENERAL INFORMATION | Product Description | Veterinary Hematology Analyzers |
| PRODUCT INFORMATION | Type of Configuration | Benchtop |
| PRODUCT INFORMATION | Type of sampling system | Closed system, Direct capillary sampling |
| PRODUCT INFORMATION | Type of operation | Fully automatic |
| PRODUCT INFORMATION | Compatible Species | Cat, Dog, Rabbit, Pig, Goat, Horse, Monkey, Canine, Equine, Feline, Bovine, Ferret, Rabbit, Gerbil, Pig, Guinea pig |
| PRODUCT INFORMATION | Automatic Start Up,shut down and sample analysis | Yes |
| PRODUCT INFORMATION | Analysis principle | Electrical resistance for counting, Electrical impedance, Calorimetry, Laser scattering method |
| PRODUCT INFORMATION | Type of cell counting | 3 part WBC differential |
| PRODUCT INFORMATION | Analysis parameter available | WBC, LYM#, MID#, GRA#, LYM%, MID%, GRA%, RBC, HGB, MCHC, MCH, MCV, RDW-CV, RDW-SD, HCT, PCT, MPV, PDW, PCT, P-LCR |
| PRODUCT INFORMATION | RBC histogram | Yes Or higher |
| PRODUCT INFORMATION | PLT histogram | Yes Or higher |
| PRODUCT INFORMATION | WBC histogram | Yes Or higher |
| PRODUCT INFORMATION | Minimum sample volume required in µL | 9 µL |
| PRODUCT INFORMATION | Maximum sample volume needed in any of modes in µL | ≤ 50 µL |
| PRODUCT INFORMATION | Throughput (samples per hour) | 30 to 60 |
| PRODUCT INFORMATION | Counting mode of the analyzer | Whole blood, peripheral and prediluted |
| PRODUCT INFORMATION | Time taken by the analyser to produce the test results (Analysis time) in seconds | 40 to 120 Secs |
| PRODUCT INFORMATION | Capability to automatically enumerate, Nucleated Red Blood Cells in the CBC/ Difference Mode and without additional reagents | Yes |
| PRODUCT INFORMATION | STAT capability with Positive Bar code identification facility for samples loading/unloading available | Yes |
| PRODUCT INFORMATION | Facility for User defined rules & flagging limits | Yes |
| PRODUCT INFORMATION | Facility for workload recording | Yes |
| PRODUCT INFORMATION | Have unlimited number of user-definable control files | Yes |
| PRODUCT INFORMATION | Quality assurance system with calibration and controls | Yes |
| PRODUCT INFORMATION | Quality control | X-R, L-J |
| PRODUCT INFORMATION | Type of Calibration | Automatic |
| PRODUCT INFORMATION | Automatic probe wipe | Yes |
| PRODUCT INFORMATION | Directly measures MCV | Yes |
| PRODUCT INFORMATION | Floating discriminator for WBC/PLT | Yes |
| PRODUCT INFORMATION | Linearity of Platelet in cells/microlitres | 0 to 2000 * 10³ cells/ micro litres |
| PRODUCT INFORMATION | Linearity of WBC in cells/micro litres | 0 to 3000 * 10³ cells/ micro litres |
| PRODUCT INFORMATION | Linearity of hemoglobin in gram per litre | 0 to 25 gm per litre |
| PRODUCT INFORMATION | Precision of WBC in % | 2.00%, 3.00% |
| PRODUCT INFORMATION | Precision of RBC in % | 1.50% |
| PRODUCT INFORMATION | Precision in HGB in % | 1.50% |
| PRODUCT INFORMATION | Precision of PLT in % | 3.00% |
| PRODUCT INFORMATION | Carryover of RBC,WBC,HGB,PLT in % | ≤ 1% |
| PRODUCT INFORMATION | Capability to differentiate between smaller RBCs and larger platelets | Yes |
| PRODUCT INFORMATION | Auto purge function in the analyzers software | Yes |
| PRODUCT INFORMATION | Availability of Auto dilution | Yes |
| PRODUCT INFORMATION | Barcode reader facility for sample | Yes |
| PRODUCT INFORMATION | Auto stop function in event of unacceptable control data | Yes |
| PRODUCT INFORMATION | Separate diluting nozzles for RBC and WBC | Yes |
| PRODUCT INFORMATION | Optimized reagents and controls | Yes |
| PRODUCT INFORMATION | Automatic electric clog removal | Yes |
| DATA MANAGEMENT AND DISPLAY | Type of data management | Inbuilt system |
| DATA MANAGEMENT AND DISPLAY | Inbuilt monitor type | LCD/LED |
| DATA MANAGEMENT AND DISPLAY | Inbuilt monitor size in inches | 8 or more |
| DATA MANAGEMENT AND DISPLAY | Data management systems | Provide scatterplots, histograms in display and print |
| DATA MANAGEMENT AND DISPLAY | Type of user Interface or data entry | Touchscreen |
| DATA MANAGEMENT AND DISPLAY | Number of USB Port | 1 |
| DATA MANAGEMENT AND DISPLAY | Database capability of storing sets of results and graphics | 50000 or more |
| DATA MANAGEMENT AND DISPLAY | Have auto cleaning function in the analyzer’s software | Yes |
| DATA MANAGEMENT AND DISPLAY | Type of printer unit | Inbuilt and external |
| ELECTRICAL REQUIREMENTS | Power supply in VAC,Hz | 220-240V, 50/60Hz single phase |
| ELECTRICAL REQUIREMENTS | UPS back up time in minutes | 15 min |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Electrical Compliance Standard | IEC 60601 or BIS Equivalent |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 4, 5 Or higher |