Panchayats And Rural Housing Department Gujarat Veterinary Hematology Analyzer Tender 2025 KHEDA IS 550 ISO 9001
N/a
KHEDA, GUJARAT
Progress
Quantity
1
Bid Type
Two Packet Bid
A tender has been published for Border Security Force (bsf) Veterinary Hematology Analyzer (V2) (Q2) in KORAPUT, ODISHA. Quantity: 1 by. Submission Deadline: 23-06-2026 21: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Veterinary Hematology Analyzer (V2) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
KHEDA, GUJARAT
Dang Collectorate
THE DANGS, GUJARAT
Banaskantha District Panchayat
BANASKANTHA, GUJARAT
Regional Ayurveda Research Institute For Gid Guwah
KAMRUP, ASSAM
Rajasthan University Of Veterinary And Animal Sciences Bikaner
BIKANER, RAJASTHAN
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL INFORMATION | Product Description | Veterinary Hematology Analyzers |
| PRODUCT INFORMATION | Type of Configuration | Benchtop |
| PRODUCT INFORMATION | Type of sampling system | Closed system, Direct capillary sampling |
| PRODUCT INFORMATION | Type of operation | Fully automatic |
| PRODUCT INFORMATION | Compatible Species | Cat, Dog, Rabbit, Pig, Goat, Horse, Monkey, Canine, Equine, Feline, Bovine, Ferret, Rabbit, Gerbil, Pig, Guinea pig |
| PRODUCT INFORMATION | Analysis principle | Electrical resistance for counting, Electrical impedance, Calorimetry, Laser scattering method |
| PRODUCT INFORMATION | Type of cell counting | 3 part WBC differential |
| PRODUCT INFORMATION | Analysis parameter available | WBC, LYM#, MID#, GRA#, LYM%, MID%, GRA%, RBC, HGB, MCHC, MCH, MCV, RDW-CV, RDW-SD, HCT, PCT, MPV, PDW, PCT, P-LCR |
| PRODUCT INFORMATION | RBC histogram | Yes Or higher |
| PRODUCT INFORMATION | PLT histogram | Yes Or higher |
| PRODUCT INFORMATION | WBC histogram | Yes Or higher |
| PRODUCT INFORMATION | Minimum sample volume required in µL | 9 µL |
| PRODUCT INFORMATION | Maximum sample volume needed in any of modes in µL | ≤ 50 µL |
| PRODUCT INFORMATION | Throughput (samples per hour) | 30 to 60 |
| PRODUCT INFORMATION | Counting mode of the analyzer | Whole blood, peripheral and prediluted |
| PRODUCT INFORMATION | Capability to automatically enumerate, Nucleated Red Blood Cells in the CBC/ Difference Mode and without additional reagents | Yes |
| PRODUCT INFORMATION | Have unlimited number of user-definable control files | Yes |
| PRODUCT INFORMATION | Quality assurance system with calibration and controls | Yes |
| PRODUCT INFORMATION | Quality control | X-R, L-J |
| PRODUCT INFORMATION | Type of Calibration | Automatic |
| PRODUCT INFORMATION | Automatic probe wipe | Yes |
| PRODUCT INFORMATION | Linearity of Platelet in cells/microlitres | 0 to 2000 * 10³ cells/ micro litres |
| PRODUCT INFORMATION | Linearity of WBC in cells/micro litres | 0 to 3000 * 10³ cells/ micro litres |
| PRODUCT INFORMATION | Linearity of hemoglobin in gram per litre | 0 to 25 gm per litre |
| PRODUCT INFORMATION | Auto stop function in event of unacceptable control data | Yes |
| PRODUCT INFORMATION | Optimized reagents and controls | Yes |
| DATA MANAGEMENT AND DISPLAY | Type of data management | Inbuilt system |
| DATA MANAGEMENT AND DISPLAY | Inbuilt monitor type | LCD/LED |
| DATA MANAGEMENT AND DISPLAY | Data management systems | Provide scatterplots, histograms in display and print |
| DATA MANAGEMENT AND DISPLAY | Database capability of storing sets of results and graphics | 50000 or more |
| DATA MANAGEMENT AND DISPLAY | Type of printer unit | Inbuilt and external |
| ELECTRICAL REQUIREMENTS | UPS back up time in minutes | 15 min |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Electrical Compliance Standard | IEC 60601 or BIS Equivalent |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 1, 2, 3, 4, 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Border Security Force (bsf)
📍 KORAPUT, ODISHA
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
Border Security Force (bsf)
📍 KORAPUT, ODISHA
Border Security Force (bsf)
📍 KORAPUT, ODISHA
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS