Gujarat Health & Family Welfare Department Ultrasound Machine Tender Rajkot Gujarat 2026 – MDR Compliance, ISI/ISO Standards
N/a
RAJKOT, GUJARAT
Progress
Quantity
1
Bid Type
Two Packet Bid
Institute Of Kidney Diseases And Research Centre (Ahmedabad, Gujarat) invites bids for a comprehensive Ultrasound Machine (V2) with a wide array of probes and advanced scan modes. Estimated value: ₹7,000,000; EMD: ₹210,000. Equipment must support broad capabilities including convex, microconvex, linear, TVS, cardiac, hockey stick, volume probes, elastography, and endorectal options. Inbuilt 3D/4D, a robust color Doppler suite, CEUS, tissue Doppler, and multiprotocol storage with DICOM 3 compliant imaging are required. Purpose: advanced nephro-urological imaging and general diagnostic ultrasound within the health system. Unique features include high frame rate, HDR imaging, QA calibration, and on-site installation with user training. This procurement emphasizes latest-generation bandwidth probes, real-time 3D imaging, and end-user ease of use across multi-user departments. The tender highlights strict compliance with MDR 2017 and mandatory medical device licenses, with OEM support and long-term spare availability. Emphasis on integrated stress echo, auto optimization, and digital storage/retrieval for patient studies.
EMD of ₹210,000 required at submission
Delivery quantity may vary up to 25% with extended delivery time
MDR 2017 compliance and medical device licensing mandatory
OEM/authorized dealer must provide 10-year spare parts availability
Complete calibration, training, and manuals to be provided
Payment terms to be as per buyer's standard; EMD required; delivery-linked payments with acceptance criteria
Delivery period to commence after original delivery order; option for up to 25% quantity with adjusted delivery time
LDs applicable per government terms for late delivery and non-conformance; detailed penalties to be specified in contract
Evidence of supplying medical ultrasound systems to healthcare facilities
Authorized OEM/ reseller with service capability in Gujarat
GST registration and financial solvency demonstrated
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Ultrasound Machine (V2) (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
64
Payment Timelines
Payments shall be made to the Seller within 30 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Pre-Bid Date
29-06-2026 11:00:00
Pre-Bid Venue
Institute of Kidney Diseases and Research Center Ground Floor, Room No. 45/board room, IKDRC Campus 1, Civil Hospital Campus, Asarwa, Ahmedabad 380016, Gujarat.
Max Delivery Days
60
Delivery Locations
1
Delivery Cities
Ahmadabad
Delivery Pincodes
380016
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Gyanani Neesha Narayandas | 380016,Central Store, Basement 1, Institute of Kidney Diseases & Research Center (IKDRC), Civil Hospital Campus, Asarwa, Ahmedabad 380016. | Ahmadabad | Gujarat | 380016 | 1 | 60 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
GEM_CATEGORY_SPECIFICATION
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
RAJKOT, GUJARAT
Civil Hospital Amdavad
AHMEDABAD, GUJARAT
N/a
LUCKNOW, UTTAR PRADESH
N/a
LUCKNOW, UTTAR PRADESH
N/a
NORTH EAST DELHI, DELHI
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Ultrasound Machine |
| Types of Probes & Features | Applications | Abdomen, Abdominal vascular, Urology, OB/GYN, Neonatal brain, Small parts (breast, thyroid, scrotal, prostate, musculoskeletal) |
| Types of Probes & Features | Convex Probe | 2.5 to 5 MHz (±2) |
| Types of Probes & Features | Microconvex probe | 4 to 8 MHz (±2) |
| Types of Probes & Features | Linear array probe | 5 to 10 MHz (±2), 3 to 12 MHz (±2), 6 to 15 MHz (±2), 6 to 18 MHz (±2), Not provided |
| Types of Probes & Features | TVS Probe | 4 to 9 MHz (±2) |
| Types of Probes & Features | Cardiac Probe | Not Provided |
| Types of Probes & Features | Hockey Stick Probe | Not Provided |
| Types of Probes & Features | Volume Convex Probe | 2.5 to 5 MHz (±2), Not Provided |
| Types of Probes & Features | Volume Linear Probe | Not Provided |
| Types of Probes & Features | Volume TVS Probe | Not Provided |
| Types of Probes & Features | Endorectal Probe | Not Provided |
| Types of Probes & Features | E-Breast Elastography technique | Yes |
| Types of Probes & Features | E-Thyroid Elastography technique | Yes |
| Types of Probes & Features | Liver Elastography technique | Yes |
| Types of Probes & Features | Gel Warmer | Yes |
| Types of Probes & Features | Dedicated 3-D/4-D | Yes, No |
| Scan Modes | B-mode | Yes |
| Scan Modes | M-mode | Yes |
| Scan Modes | Contrast harmonic imaging with angio mode | Yes |
| Scan Modes | Tissue harmonic imaging mode | Yes |
| Scan Modes | Provision of Harmonic imaging in Linear Probes | Yes |
| Scan Modes | Color Doppler imaging (CDI) | Yes |
| Scan Modes | Color Doppler 3-D/4-D option | Yes, No |
| Scan Modes | Power Doppler imaging (PDI) | Yes |
| Scan Modes | Power Doppler 3-D/4-D option | Yes, No |
| Scan Modes | Continuous wave | Yes |
| Scan Modes | Pulsed wave | Yes |
| Scan Modes | Duplex mode | Yes |
| Scan Modes | Triplex mode | Yes |
| Scan Modes | Tissue Doppler imaging | Yes |
| Scan Modes | Contrast-enhanced ultrasound (CEUS) option | Yes |
| Scan Modes | Tissue synchronization, tissue velocity | Yes |
| Scan Modes | Gain control in two dimensions for additional level of flexibility for image quality control | Yes |
| Scan Modes | Provision for higher resolution | Real time high frequency 2D |
| Scan Modes | Probes supplied shall be in latest generation bandwidth | Yes |
| Scan Modes | Provision for higher sensitivity for low frequency doppler in all probes | Yes |
| Scan Modes | Number of channels in color doppler system | 300000 or more (if channels are being designated as digital channels) |
| Scan Modes | Live 3 D imaging in color doppler system | Yes |
| Scan Modes | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes |
| Scan Modes | Number of grey shades for sharp contrast resolutions in db | 256 or more |
| Scan Modes | High-definition acoustic zoom provision for enlarging sections of 2D and Colour flow images with more acoustic information for greater clarity and detail while maintaining an optimal frame rate | Yes |
| Scan Modes | Colour Flow Imaging Option | Yes |
| Scan Modes | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes |
| Scan Modes | All application packages should be inbuilt into the system | Yes |
| Scan Modes | Cine Loop Features | Yes |
| Scan Modes | Cine Loop Memory in MB | >=100 |
| Scan Modes | Frame grabber facility for post analysis | Yes |
| Scan Modes | User defined system and application presets for multi-user department | Yes |
| Scan Modes | Number of transducer/probe ports | 4 or More |
| Scan Modes | System should be capable of generating real time live 3- D images | Yes |
| Scan Modes | Contrast agent imaging | Yes |
| Scan Modes | Color Doppler system with all applications package, quad loop for serial studies with high frame rate, harmonic imaging capability in all modes and digital storage and retrieval | Yes |
| Image Display and Processing | DICOM 3 Compliant | Yes |
| Image Display and Processing | Adjustable transmit focus | Yes |
| Image Display and Processing | Automated B-mode (2-D) image | Yes |
| Image Display and Processing | Automated CDI(Color Doppler Imaging) image optimization | Yes |
| Image Display and Processing | Automated PW Doppler image optimization | Yes |
| Image Display and Processing | Dynamic receive focus | Yes |
| Image Display and Processing | Grayscale levels | 256 |
| Image Display and Processing | Image magnification (zoom) | Yes |
| Image Display and Processing | Real-time image | Yes |
| Image Display and Processing | Frozen image | Yes |
| Image Display and Processing | Touch Screen | Yes |
| Image Display and Processing | Monitor shall have high-resolution | Yes |
| Image Display and Processing | Provision of Tilt or Swivel monitor should be able to view in all angles and all light conditions | Yes |
| Image Display and Processing | Type of Display | LCD/LED |
| Image Display and Processing | Monitor display size (inch) | 15 or more, 17 or more, 19 or more, 21 or more Or higher |
| Image Display and Processing | Split screen | Twin View and Live Quad Screen |
| Image Display and Processing | Single/dual monitors | Dual (image display and touch panel) |
| Image Display and Processing | Depth, cm | ≥30 |
| Image Display and Processing | Pre processing | Yes |
| Image Display and Processing | Post processing | Yes |
| Image Display and Processing | Selectable dynamic range (dB) | >=200 |
| Image Display and Processing | Spectrum analyzer | Yes |
| Image Display and Processing | Digital Image Storage | Yes |
| Image Display and Processing | Cine loop playback | Yes |
| Image Display and Processing | Max number frames | >=1000, >=500 |
| Image Display and Processing | Digital storage hard drive, GB | >=500 |
| Image Display and Processing | Speckle-tracking strain and strain rate | No |
| Image Display and Processing | Exam protocols | Yes |
| Image Display and Processing | Digital calipers | Yes |
| Image Display and Processing | Exam presets | Yes |
| Image Display and Processing | Customizable presets | Yes |
| Image Display and Processing | On-screen annotation | Yes |
| Image Display and Processing | DVD/CD Writer/ USB | Yes |
| Image Display and Processing | Flash Memory | Yes |
| Image Display and Processing | USB connector | Yes |
| Image Display and Processing | Facility for high definition digital acquisition, review and editing of complete patient studies | Yes |
| Image Display and Processing | Type of processor (in PC) | i7 or latest, NA |
| Image Display and Processing | RAM capacity of PC in GB (hint: In case PC not provided put zero) | ≥ 4 |
| Image Display and Processing | Processor speed in GHz (PC) | ≥ 3 |
| Image Display and Processing | Frame Grabber incorporated(PC) | Yes, No |
| Image Display and Processing | Connectivity between USG and PC | Yes |
| Image Display and Processing | PC with all software inclusive interfaced with USG machine | Yes, No |
| Image Display and Processing | Laser Color printer provided | Yes, No |
| Image Display and Processing | Inkjet/Thermal printer provided | Yes, No |
| Image Display and Processing | CD/DVD/USB Produced should be playable on any system | Yes, No |
| Image Display and Processing | Glossy Colour Print Paper supplied | 500 sheets, 1000 sheets, NA |
| Image Display and Processing | Dicom Interfacability Dicom to PACS | Yes |
| Image Display and Processing | Interfacability Dicom to RIS | Yes |
| Image Display and Processing | USG sytem supplied should be upgradable to next generation system on site | Yes |
| Power Requirements | Power input, VAC | 220-240VAC, 50Hz fitted with Indian plug |
| Power Requirements | Resettable over current breaker shall be fitted for protection | Yes |
| Power Requirements | Power backup | UPS |
| Power Requirements | Back up time in minutes (minimum) | 30.0 |
| Power Requirements | Suitable Servo Controlled Stabilizer / CVT should be provided | Yes, No |
| Certifications | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| Certifications | Availability of valid drug/Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| Certifications | Certification for manufacturing unit | ISO:13485 (Latest) |
| Certifications | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| Certifications | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| Certifications | Electrical Safety standards | IEC-60601-1-1 or equivalent BIS |
| Warranty and Maintenance | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
| Miscellaneous Requirements | OEM/Reseller shall ensure uninterrupted availability of all spares, consumables and reagents for atleast 10 years | Yes |
| Miscellaneous Requirements | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| Miscellaneous Requirements | User/Technical/Maintenance manuals to be provided in English in hard and soft copy | Yes |
| Miscellaneous Requirements | Details of equipments and procedures required for local calibration and routine maintenance to be provided and advanced maintenance task documentation also to be furnished | Yes |
| Miscellaneous Requirements | Supplier to perform installation, safety and operation checks before handover | Yes |
| Miscellaneous Requirements | Training of users in operation and basic maintenance shall be provided | Yes |
| Miscellaneous Requirements | Contact details of manufacturer, supplier and local service agent to be provided | Yes |
| Miscellaneous Requirements | Certificate of calibration from the manufacturer | Yes |
Discover companies most likely to bid on this tender
GST certificate
PAN card
Experience certificates (certificate of prior supply of ultrasound systems)
Financial statements (last 3 years)
EMD payment receipt or guaranty
Technical bid detailing compliance with MDR 2017 and DICOM 3 compliance
OEM authorization / dealer authorization
Manufacturing unit certification
Test reports for supplied batches per MDR 2017
Calibrations certificates
Maintenance manuals (English) and user manuals
Local service support details with toll-free numbers
Key insights about GUJARAT tender market
Bidders must submit the EMD of ₹210,000 along with GST, PAN, OEM authorization, experience certificates, and financial statements. The equipment must be MDR 2017 compliant with DICOM 3, include 3D/4D and elastography features, and comply with 10-year spare parts availability. Prepare installation and training plans.
Required documents include GST certificate, PAN, OEM authorization, experience certificates, last 3 years financial statements, calibration certificates, MDR compliance evidence, test reports for batches, and English user manuals. Also include bid technical details and maintenance support information.
The system must support convex, linear, and endorectal probes plus elastography (breast, thyroid, liver). It requires B/M modes, color/Power Doppler, 3D/4D color, CEUS, tissue Doppler, DICOM 3 compliance, high-resolution display, and robust storage with cine loop and RIS/PACS interfacing.
EMD is ₹210,000. Submit payment via electronic mode or demand draft as per procurement terms; ensure EMD accompanies the bid submission and is referenced in the bid cover. EMD validity should extend until award and beyond as per policy.
Delivery can vary up to 25% in quantity with extended delivery time. An optional comprehensive warranty is available; standard warranty applies if not opted. Spare parts must be available for 10 years, with OEM support and on-site installation including training.
Submit MDR 2017 compliance certificates, drug/medical device license, and manufacturing unit certification. Include test reports per MDR, and evidence of calibration procedures. Ensure supplier demonstrates ongoing compliance and post-sale service capabilities.
Provide on-site installation, safety checks, user training for operation and basic maintenance, and English manuals (hard and soft copy). Include local service contact details and a toll-free technical support mechanism maintained by OEM or authorized agents.
OEM authorization or authorized reseller status is required, with guaranteed availability of spares for at least 10 years. The bid emphasizes latest-generation bandwidth probes and integrated application packages with full compatibility across modes and storage systems.
All India Institute Of Medical Sciences (aiims)
📍 RAIPUR, CHHATTISGARH
Western Railway
📍 MUMBAI, MAHARASHTRA
N/a
📍 CHAMBA, HIMACHAL PRADESH
Pimpri Chinchwad Municipal Corporation
📍 PUNE, MAHARASHTRA
Indian Air Force
Sign up now to access all documents
Main Document
GEM_CATEGORY_SPECIFICATION
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS