Bid Publish Date
18-Aug-2026, 5:06 pm
Bid End Date
01-Sep-2026, 11:00 am
Location
Progress
A tender has been published for Nuclear Power Corporation Of India Limited Syringe Infusion Pump (Q2), Volumetric Infusion Pump (Q2) in UTTARA KANNADA, KARNATAKA. Quantity: 8 by. Submission Deadline: 01-09-2026 11: 00: 00. Check eligibility and apply.
Quantity
8
Category
Syringe Infusion Pump
Bid Type
Single Packet Bid
Bid Validity
90 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
7 Days
EMD Required
No
MII Purchase Preference
No
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Syringe Infusion Pump (Q2) , Volumetric Infusion Pump (Q2)
Payment Timelines
Payments shall be made to the Seller within 10 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
30
Delivery Locations
1
Delivery Cities
Uttara Kannada
Delivery Pincodes
581400
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Santosh Kulkarni | 581400,Plant Site, Kaiga Generating Station, PO: Kaiga | Uttara Kannada | Karnataka | 581400 | 4 | 30 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
CATALOG Specification
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Syringe infusion pump |
| PRODUCT INFORMATION | Operating Modes | Flow Rate Mode, Volume and Time, Rate and Time, Weight Mode, Sequence Mode |
| PRODUCT INFORMATION | Flow rate Range in ml/hr | 0.01 - 1500 ml/hr, 0.01 - 2000 ml/hr, 0.1 - 2000 ml/hr Or higher |
| PRODUCT INFORMATION | Flowrate Increment in ml/hr | 0.1 ml/hr, 1 ml/hr |
| PRODUCT INFORMATION | KVO (Keep Vein Open) Rate in ml/hr | 0.1 to 5 ml/hr adjustable, step 0.1ml/h, 0.1 to 3 ml/hr adjustable, step 0.1ml/h |
| PRODUCT INFORMATION | Bolus Administration | Manual and automatic |
| PRODUCT INFORMATION | Bolus Volume in ml | 0.1 - 5 ml in 0.1 ml increments (auto bolus) |
| PRODUCT INFORMATION | Minimum Display Size in inches | 3 or more, 2.4 or more Or higher |
| PRODUCT INFORMATION | Display Paramaters | Flow rate, Syringe Size, Infused volume, Power indicator light, Occlusions, Drug Name, Battery Indicator |
| PRODUCT INFORMATION | Syringe compatibility: The pump should work with different brands of syringes and is able to automatically detect and accept syringes with volumes of | 5 ml, 10 ml, 20 ml, 50 ml |
| PRODUCT INFORMATION | Audio Visual alarm for | Occlusion, Syringe near-empty, Syringe-empty, Low battery, Internal malfunction, Syringe wrongly fitted, Power supply failure |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 1, 3, 5 Or higher |