Bid Publish Date
31-Aug-2026, 1:24 pm
Bid End Date
28-Sep-2026, 2:00 pm
EMD
₹50,000
Value
₹10,00,000
Location
Progress
Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer) has released a public tender for Automated Blood Culture System (Q2) in PONDICHERRY, PUDUCHERRY. Quantity: 1. Submission Deadline: 28-09-2026 14: 00: 00. Download documents and apply online.
Quantity
1
Bid Type
Two Packet Bid
Bid Validity
180 (Days)
Bid Type
Service
Evaluation
Total value wise evaluation
Inspection Required
No
Tech Clarification Time
2 Days
EMD Required
Yes
MII Purchase Preference
No
MSE Purchase Preference
Yes
MSE Preference Band
L1+15%
MSE Exemption/Relaxation
No
Startup Exemption/Relaxation
No
Bid Splitting Applied
No
Min. Avg. Annual Turnover
5
OEM Avg. Turnover
40
Past Performance
50 %
Experience Required
2 Year (s)
Arbitration Clause
No
Mediation Clause
No
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Automated Blood Culture System (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
3%
ePBG Duration (Months)
14
Max Delivery Days
28
Delivery Locations
1
Delivery Cities
Pondicherry
Delivery Pincodes
605006
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| MURUGESAN | 605006,Jawaharlal Institute of Postgraduate Medical Education and Research, Dhanvantari Nagar, Puducherry | Pondicherry | Puducherry | 605006 | 1 | 28 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Additional Doc 3 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Automated Blood Culture System |
| PRODUCT INFORMATION | Technology | Fluorometric technology / Colorimetric technology / Non-radiometric technology |
| PRODUCT INFORMATION | Patient usage | Adult and Pediatric |
| PRODUCT INFORMATION | Type of Culture Bottles Supported | Aerobic, Anaerobic, Fungal |
| PRODUCT INFORMATION | Sample Capacity (Minimum) | 120 bottles or more, 200 bottles or more, 360 bottles or more Or higher |
| PRODUCT INFORMATION | System should have the capability of continuous monitoring of all samples for growth of micro-organisms | Yes |
| PRODUCT INFORMATION | System should be able to display growth kinetics on the screen and have the capacity to generate hard copy of each growth kinetics | Yes |
| PRODUCT INFORMATION | System should have the facility to analyse delayed specimens with the routine bottles | Yes |
| PRODUCT INFORMATION | System should be having continuous agitation and incubation facility to provide optimal growth of microorganisms | Yes |
| PRODUCT INFORMATION | System should have in-built calibration check / facilitate calibration | Yes |
| PRODUCT INFORMATION | Media bottles should have the capacity to neutralize antibiotics | Yes |
| PRODUCT INFORMATION | Visual and audible alarms for positive cultures | Yes |
| PRODUCT INFORMATION | Every cell (bottle position) have its own optics and detection device | Yes |
| PRODUCT INFORMATION | System should have data management system and software to analyze and store the data | Yes |
| PRODUCT INFORMATION | Barcode Reader | Built-in / External |
| DATA MANAGEMENT SYSTEM | Type of monitor | Inbuilt / PC Based |
| DATA MANAGEMENT SYSTEM | Type of monitor display | LCD / LED |
| DATA MANAGEMENT SYSTEM | Touch screen display | Yes |
| DATA MANAGEMENT SYSTEM | UPS provided for Power Backup facility | Yes |
| DATA MANAGEMENT SYSTEM | UPS Back up time in minutes | 30 minutes or more |
| DATA MANAGEMENT SYSTEM | Availability of external printer | Yes |
| DATA MANAGEMENT SYSTEM | Connectivity | LIS / HIS compatibility |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Conformity to electrical safety requirements | IEC 60601 / 61010 latest amended or BIS equivalent |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 1.0, 5.0 |