Bid Publish Date
14-Jan-2025, 6:12 pm
Bid End Date
04-Feb-2025, 11:00 am
EMD
₹1,23,031
Value
₹61,51,544
Location
Progress
Quantity
968
Category
SITC of 7TR Copeland Model ZR108KCE scroll compressor
Bid Type
Two Packet Bid
Bharat Sanchar Nigam Limited Portal(bsnl) invites bids for SITC of 7TR Copeland Model ZR108KCE scroll compressor, Providing Nitrogen pressure testing and vacuumising the entire refrigerant system, Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit, SITC of Blower motor Electronic commuted 3 phase 380 to 480 V 50 60 Hz 3 point 1 KW 1560 rpm for Emerson make 7 TR bottom feed Precision AC, SITC Condenser motor with axial fan blade, Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make, Expansion Valve Carel make, High pressure gas Solenoid valve unit suitable for Emerson make 7 TR HPAC, LP Cut Out Switch for Emerson make 7 TR HPAC, HP Cut Out Switch for Emerson make 7 TR HPAC, Crankcase heater for scroll compressor of Copeland Model ZR108KCE, IOC Card controller ICOM Board for Emerson make 7 TR HPAC, EVD Pressure switch for Emerson make 7 TR HPAC, SITC of 4P 63A 25kA breaking capacity MCCB 3VTI Siemens or SS, Fuse set PCB card, Contactor 4 pole 32 Amps MCX03 Coil Supply 220V, Contactor addon block, Return Air Sensor, Control Transformer Primary 380 V to 415 V Secondary 1 0 to 22 V 2A Sec 2 0 to 24 V 6 A, Attending defects in control wiring, SITC of 7 TR Copeland Model ZR108KCE scroll compressor, Providing Nitrogen pressure testing and vacuuming the entire refrigerant system, IOC Card Controller ie ICOM Board for Emerson make 15 TR HPAC, LP Cut Out Switch for Emerson make 15 TR HPAC, HP Cut Out Switch for Emerson make 15 TR HPAC, V belt for blower of 15 TR Emerson make HPAC unit, 4 Pole 32 Amp Contactor for blower motor, 3 Pole 40 Amp Contactor for compressor, Rewinding of Blower motor rating 3 phase 415 V Induction motor 3 HP 1430 rpm, Condenser motor with axial fan blade, Attending defects in control Wiring, Providing nitrogen pressure testing and vacuumising the entire refrigerant system, Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Stulz make 7 TR HPAC, High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC, LP Cut Out Switch for Stulz make 7 TR HPAC, HP Cut Out Switch for Stulz make 7 TR HPAC, SITC of Condenser motor with axial fan blade and safety grill, Crankcase heater for scroll compressor, SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC, SITC of 7 TR Copeland, Model ZR108KCE scroll compressor, IOC Card Controller i. e. ICOM Board for Emerson make 15 TR HPAC, 4 Pole 32 Amp, Contactor for blower motor, Rewinding of Blower motor, rating 3 phase 415 V Induction motor, 3. 0 HP, 1430 rpm, Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Stulz make 7 TR HPAC. , High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC. in PUNE, MAHARASHTRA. Quantity: 968. Submission Deadline: 04-02-2025 11: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
SITC of 7TR Copeland Model ZR108KCE scroll compressor , Providing Nitrogen pressure testing and vacuumising the entire refrigerant system , Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit , SITC of Blower motor Electronic commuted 3 phase 380 to 480 V 50 60 Hz 3 point 1 KW 1560 rpm for Emerson make 7 TR bottom feed Precision AC , SITC Condenser motor with axial fan blade , Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make , Expansion Valve Carel make , High pressure gas Solenoid valve unit suitable for Emerson make 7 TR HPAC , LP Cut Out Switch for Emerson make 7 TR HPAC , HP Cut Out Switch for Emerson make 7 TR HPAC , Crankcase heater for scroll compressor of Copeland Model ZR108KCE , IOC Card controller ICOM Board for Emerson make 7 TR HPAC , EVD Pressure switch for Emerson make 7 TR HPAC , SITC of 4P 63A 25kA breaking capacity MCCB 3VTI Siemens or SS , Fuse set PCB card , Contactor 4 pole 32 Amps MCX03 Coil Supply 220V , Contactor addon block , Return Air Sensor , Control Transformer Primary 380 V to 415 V Secondary 1 0 to 22 V 2A Sec 2 0 to 24 V 6 A , Attending defects in control wiring , SITC of 7 TR Copeland Model ZR108KCE scroll compressor , Providing Nitrogen pressure testing and vacuuming the entire refrigerant system , IOC Card Controller ie ICOM Board for Emerson make 15 TR HPAC , LP Cut Out Switch for Emerson make 15 TR HPAC , HP Cut Out Switch for Emerson make 15 TR HPAC , V belt for blower of 15 TR Emerson make HPAC unit , 4 Pole 32 Amp Contactor for blower motor , 3 Pole 40 Amp Contactor for compressor , Rewinding of Blower motor rating 3 phase 415 V Induction motor 3 HP 1430 rpm , Condenser motor with axial fan blade , Attending defects in control Wiring , Providing nitrogen pressure testing and vacuumising the entire refrigerant system , Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Stulz make 7 TR HPAC , High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC , LP Cut Out Switch for Stulz make 7 TR HPAC , HP Cut Out Switch for Stulz make 7 TR HPAC , SITC of Condenser motor with axial fan blade and safety grill , Crankcase heater for scroll compressor , SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC , SITC of 7 TR Copeland, Model ZR108KCE scroll compressor , IOC Card Controller i.e. ICOM Board for Emerson make 15 TR HPAC , 4 Pole 32 Amp, Contactor for blower motor , Rewinding of Blower motor, rating 3 phase 415 V Induction motor, 3.0 HP, 1430 rpm , Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Stulz make 7 TR HPAC. , High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
OTHER
BOQ
BOQ
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
SITC of 7TR Copeland Model ZR108KCE scroll compressor
SITC of 7 TR Copeland Model ZR108KCE scroll compressor including removing of old compressor pumping down refrigerant gas etc as reqd Rate shall be after discount for exchange of old compressor
Providing Nitrogen pressure testing and vacuumising the entire refrigerant system
Providing Nitrogen pressure for testing of leakage arresting leakage by brazing or other suitable means etc including vaccumizing dehydrating entire refrigerant system as reqd
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd
SITC of Blower motor Electronic commuted 3 phase 380 to 480 V 50 60 Hz 3 point 1 KW 1560 rpm for Emerson make 7 TR bottom feed Precision AC
SITC of electronically Commutated blower motor 3 phase 380 to 480 V 50 60 Hz 3 point 1 KW 1560 rpm with integrated electronics suitable for Emerson make 7 TR bottom feed Precision AC as reqd
SITC Condenser motor with axial fan blade
SITC of Condenser motor with axial fan blades and safety grill outdoor 400V 50Hz AC 28 inch dia point 62 KW 1 point 7A 1 point 05 A 900 600 RPM suitable for Emerson make 7TR Precision AC as reqd
Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make
Replacing Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Emerson make 7 TR HPAC as reqd
Expansion Valve Carel make
Replacing Expansion Valve Carel make suitable for 7 TR HPAC unit Emerson as reqd
High pressure gas Solenoid valve unit suitable for Emerson make 7 TR HPAC
Replacing High pressure gas Solenoid valve unit suitable for Emerson make 7 TR HPAC as reqd
LP Cut Out Switch for Emerson make 7 TR HPAC
Replacing LP Cut Out Switch suitable for Emerson make 7 TR HPAC as reqd
HP Cut Out Switch for Emerson make 7 TR HPAC
Replacing HP Cut Out Switch suitable for Emerson make 7 TR HPAC as reqd
Crankcase heater for scroll compressor of Copeland Model ZR108KCE
Replacing Crankcase heater for 7 TR Copeland Model ZR108KCE scroll compressor as reqd
IOC Card controller ICOM Board for Emerson make 7 TR HPAC
Replacing IOC Card controller ICOM Board suitable for Emerson make 7 TR HPAC unit as reqd
EVD Pressure switch for Emerson make 7 TR HPAC
Replacing EVD Pressure switch suitable for Emerson make 7 TR HPAC unit as reqd
SITC of 4P 63A 25kA breaking capacity MCCB 3VTI Siemens or SS
SITC of 4P 63A 25kA breaking capacity MCCB 3VTI Siemens or SS in Emerson make 7 TR HPAC unit as reqd
Fuse set PCB card
Replacing Fuse set PCB card suitable for Emerson make 7 TR HPAC unit as reqd
Contactor 4 pole 32 Amps MCX03 Coil Supply 220V
Replacing of Contactor 4 pole 32 Amps MCX03 Coil Supply 220V
Contactor addon block
Replacing of Contactor addon block
Return Air Sensor
Replacing of Return Air Sensor suitable for Emerson make 7 TR HPAC unit as reqd
Control Transformer Primary 380 V to 415 V Secondary 1 0 to 22 V 2A Sec 2 0 to 24 V 6 A
Replacing of Control Transformer with Primary 380 V to 415 V Secondary 1 0 V to 22 V 2A and Secondary 2 0V to 24 V 6 A suitable for Emerson make 7 TR HPAC unit as reqd
Attending defects in control wiring
Attending defects in control wiring making safety operational Master slave configuration for sequential running of package communication setting of all parameters etc as reqd
SITC of 7 TR Copeland Model ZR108KCE scroll compressor
SITC of 7 TR Copeland Model ZR108KCE scroll compressor including removing of old compressor pumping down refrigerant gas etc as reqd Rate shall be after discount for exchange of old compressor
Providing Nitrogen pressure testing and vacuuming the entire refrigerant system
Providing Nitrogen pressure for testing of leakage arresting leakage by brazing or other suitable means etcincluding vacuuming dehydrating entire refrigerant system as reqd
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd
IOC Card Controller ie ICOM Board for Emerson make 15 TR HPAC
Replacing IOC Card controller ICOM Board suitable for Emerson make 15 TR HPAC Model No GLOBEL PEX2 1030 as reqd
LP Cut Out Switch for Emerson make 15 TR HPAC
Replacing LP Cut Out Switch for one ckt of Emerson make 15 TR HPAC Model No GLOBEL PEX2 1030 as reqd
HP Cut Out Switch for Emerson make 15 TR HPAC
Replacing of HP Cut Out Switch for one ckt of Emerson make 15 TR HPAC Model No GLOBEL PEX2 1030 as reqd
V belt for blower of 15 TR Emerson make HPAC unit
Replacing V belt for blower of Emerson make 15 TR HPAC unit as reqd
4 Pole 32 Amp Contactor for blower motor
Replacing of 4 Pole 32 Amp contactor for blower motor as reqd Make LnT Model AC 3 MCX 03 or SS
3 Pole 40 Amp Contactor for compressor
Replacing of 3 Pole 40 Amp Contactor for compressor as reqd Make LnT Model AC 3 or SS
Rewinding of Blower motor rating 3 phase 415 V Induction motor 3 HP 1430 rpm
Rewinding of Blower motor of rating 3 phase 415 V Induction motor 3 HP 1430 rpm including replacing of ball bearing etc as reqd
Condenser motor with axial fan blade
SITC of Condenser motor with axial fan blades and safety grill housing suitable for single phase 250 W 1350 RPM for 7TR HPAC unit of Emerson Make ZIEHLABEGG Transmonk or SS
Attending defects in control Wiring
Attending defects in control Wiring making safety operational Master slave configuration for sequential running of package communication setting of all parameters etc as reqd
Providing nitrogen pressure testing and vacuumising the entire refrigerant system
Providing nitrogen pressure for testing of leakage arresting leakage by brazing or other suitable means etc including vaccumizing dehydrating entire refrigerant system as reqd
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd
Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Stulz make 7 TR HPAC
Replacing Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel suitable for Stulz make HPAC as reqd
High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC
Replacing High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC as reqd
LP Cut Out Switch for Stulz make 7 TR HPAC
Replacing LP Cut Out Switch for Stulz make 7 TR HPAC as reqd
HP Cut Out Switch for Stulz make 7 TR HPAC
Replacing HP Cut Out Switch for Stulz make 7 TR HPAC as reqd
SITC of Condenser motor with axial fan blade and safety grill
SITC of 1Ph 250 W 1350 RPM condenser motor with axial fan blades and safety grill for 7TR HPAC unit of Stulz Make ZIEHLABEGGTransmonk or SS
Crankcase heater for scroll compressor
Replacing Crankcase heater for scroll compressor of 7 TR HPAC unit of Stulz as reqd
SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC
SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC complete as required
SITC of 7 TR Copeland, Model ZR108KCE scroll compressor
SITC of 7 TR Copeland Model ZR108KCE scroll compressor including removing of old compressor, pumping down refrigerant gas etc. as reqd. Rate shall be after discount for exchange of old compressor.
Providing Nitrogen pressure testing and vacuuming the entire refrigerant system
Providing Nitrogen pressure for testing of leakage, arresting leakage by brazing or other suitable means etc. including vacuuming dehydrating entire refrigerant system as reqd.
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd.
IOC Card Controller i.e. ICOM Board for Emerson make 15 TR HPAC
Replacing IOC Card controller ICOM Board suitable for Emerson make 15 TR HPAC Model No. GLOBEL PEX2 1030 as reqd.
LP Cut Out Switch for Emerson make 15 TR HPAC
Replacing LP Cut Out Switch for one ckt of Emerson make 15 TR HPAC Model No. GLOBEL PEX2 1030 as reqd.
HP Cut Out Switch for Emerson make 15 TR HPAC
Replacing of HP Cut Out Switch for one ckt of Emerson make 15 TR HPAC Model No. GLOBEL PEX2 1030 as reqd.
V belt for blower of 15 TR Emerson make HPAC unit
Replacing V belt for blower of Emerson make 15 TR HPAC unit as reqd.
4 Pole 32 Amp, Contactor for blower motor
Replacing of 4 Pole 32 Amp contactor for blower motor as reqd. Make LnT Model AC 3, MCX 03 or SS.
3 Pole 40 Amp Contactor for compressor
Replacing of 3 Pole 40 Amp Contactor for compressor as reqd. Make LnT Model AC 3 or SS.
Rewinding of Blower motor, rating 3 phase 415 V Induction motor, 3.0 HP, 1430 rpm
Rewinding of Blower motor of rating 3 phase 415 V Induction motor, 3.0 HP, 1430 rpm including replacing of ball bearing, etc. as reqd.
Condenser motor with axial fan blade
SITC of Condenser motor with axial fan blades and safety grill housing suitable for single phase 250 W 1350 RPM for 7TR HPAC unit of Emerson. Make ZIEHLABEGG,Transmonk or SS.
Attending defects in control Wiring
Attending defects in control Wiring, making safety operational, Master slave configuration for sequential running of package, communication, setting of all parameters, etc. as reqd.
Providing nitrogen pressure testing and vacuumising the entire refrigerant system
Providing nitrogen pressure for testing of leakage, arresting leakage by brazing or other suitable means etc. including vaccumizing dehydrating entire refrigerant system as reqd.
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit
Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd.
Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Stulz make 7 TR HPAC.
Replacing Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel suitable for Stulz make HPAC as reqd.
High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC.
Replacing High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC as reqd.
LP Cut Out Switch for Stulz make 7 TR HPAC
Replacing LP Cut Out Switch for Stulz make 7 TR HPAC as reqd.
HP Cut Out Switch for Stulz make 7 TR HPAC
Replacing HP Cut Out Switch for Stulz make 7 TR HPAC as reqd.
SITC of Condenser motor with axial fan blade and safety grill
SITC of 1Ph 250 W 1350 RPM condenser motor with axial fan blades and safety grill for 7TR HPAC unit of Stulz. Make ZIEHLABEGG,Transmonk or SS
Crankcase heater for scroll compressor
Replacing Crankcase heater for scroll compressor of 7 TR HPAC unit of Stulz as reqd.
SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC
SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC complete as required.
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | SITC of 7TR Copeland Model ZR108KCE scroll compressor | SITC of 7 TR Copeland Model ZR108KCE scroll compressor including removing of old compressor pumping down refrigerant gas etc as reqd Rate shall be after discount for exchange of old compressor | 6 | job | vijay.londhe | 60 | |
| 2 | Providing Nitrogen pressure testing and vacuumising the entire refrigerant system | Providing Nitrogen pressure for testing of leakage arresting leakage by brazing or other suitable means etc including vaccumizing dehydrating entire refrigerant system as reqd | 10 | job | vijay.londhe | 60 | |
| 3 | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd | 259 | kg | vijay.londhe | 60 | |
| 4 | SITC of Blower motor Electronic commuted 3 phase 380 to 480 V 50 60 Hz 3 point 1 KW 1560 rpm for Emerson make 7 TR bottom feed Precision AC | SITC of electronically Commutated blower motor 3 phase 380 to 480 V 50 60 Hz 3 point 1 KW 1560 rpm with integrated electronics suitable for Emerson make 7 TR bottom feed Precision AC as reqd | 3 | each | vijay.londhe | 60 | |
| 5 | SITC Condenser motor with axial fan blade | SITC of Condenser motor with axial fan blades and safety grill outdoor 400V 50Hz AC 28 inch dia point 62 KW 1 point 7A 1 point 05 A 900 600 RPM suitable for Emerson make 7TR Precision AC as reqd | 11 | each | vijay.londhe | 60 | |
| 6 | Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make | Replacing Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Emerson make 7 TR HPAC as reqd | 13 | each | vijay.londhe | 60 | |
| 7 | Expansion Valve Carel make | Replacing Expansion Valve Carel make suitable for 7 TR HPAC unit Emerson as reqd | 7 | each | vijay.londhe | 60 | |
| 8 | High pressure gas Solenoid valve unit suitable for Emerson make 7 TR HPAC | Replacing High pressure gas Solenoid valve unit suitable for Emerson make 7 TR HPAC as reqd | 5 | each | vijay.londhe | 60 | |
| 9 | LP Cut Out Switch for Emerson make 7 TR HPAC | Replacing LP Cut Out Switch suitable for Emerson make 7 TR HPAC as reqd | 10 | each | vijay.londhe | 60 | |
| 10 | HP Cut Out Switch for Emerson make 7 TR HPAC | Replacing HP Cut Out Switch suitable for Emerson make 7 TR HPAC as reqd | 8 | each | vijay.londhe | 60 | |
| 11 | Crankcase heater for scroll compressor of Copeland Model ZR108KCE | Replacing Crankcase heater for 7 TR Copeland Model ZR108KCE scroll compressor as reqd | 1 | each | vijay.londhe | 60 | |
| 12 | IOC Card controller ICOM Board for Emerson make 7 TR HPAC | Replacing IOC Card controller ICOM Board suitable for Emerson make 7 TR HPAC unit as reqd | 5 | each | vijay.londhe | 60 | |
| 13 | EVD Pressure switch for Emerson make 7 TR HPAC | Replacing EVD Pressure switch suitable for Emerson make 7 TR HPAC unit as reqd | 1 | each | vijay.londhe | 60 | |
| 14 | SITC of 4P 63A 25kA breaking capacity MCCB 3VTI Siemens or SS | SITC of 4P 63A 25kA breaking capacity MCCB 3VTI Siemens or SS in Emerson make 7 TR HPAC unit as reqd | 1 | each | vijay.londhe | 60 | |
| 15 | Fuse set PCB card | Replacing Fuse set PCB card suitable for Emerson make 7 TR HPAC unit as reqd | 1 | each | vijay.londhe | 60 | |
| 16 | Contactor 4 pole 32 Amps MCX03 Coil Supply 220V | Replacing of Contactor 4 pole 32 Amps MCX03 Coil Supply 220V | 10 | each | vijay.londhe | 60 | |
| 17 | Contactor addon block | Replacing of Contactor addon block | 3 | each | vijay.londhe | 60 | |
| 18 | Return Air Sensor | Replacing of Return Air Sensor suitable for Emerson make 7 TR HPAC unit as reqd | 2 | each | vijay.londhe | 60 | |
| 19 | Control Transformer Primary 380 V to 415 V Secondary 1 0 to 22 V 2A Sec 2 0 to 24 V 6 A | Replacing of Control Transformer with Primary 380 V to 415 V Secondary 1 0 V to 22 V 2A and Secondary 2 0V to 24 V 6 A suitable for Emerson make 7 TR HPAC unit as reqd | 2 | each | vijay.londhe | 60 | |
| 20 | Attending defects in control wiring | Attending defects in control wiring making safety operational Master slave configuration for sequential running of package communication setting of all parameters etc as reqd | 6 | each | vijay.londhe | 60 | |
| 21 | SITC of 7 TR Copeland Model ZR108KCE scroll compressor | SITC of 7 TR Copeland Model ZR108KCE scroll compressor including removing of old compressor pumping down refrigerant gas etc as reqd Rate shall be after discount for exchange of old compressor | 7 | job | vijay.londhe | 60 | |
| 22 | Providing Nitrogen pressure testing and vacuuming the entire refrigerant system | Providing Nitrogen pressure for testing of leakage arresting leakage by brazing or other suitable means etcincluding vacuuming dehydrating entire refrigerant system as reqd | 7 | job | vijay.londhe | 60 | |
| 23 | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd | 151 | kg | vijay.londhe | 60 | |
| 24 | IOC Card Controller ie ICOM Board for Emerson make 15 TR HPAC | Replacing IOC Card controller ICOM Board suitable for Emerson make 15 TR HPAC Model No GLOBEL PEX2 1030 as reqd | 2 | each | vijay.londhe | 60 | |
| 25 | LP Cut Out Switch for Emerson make 15 TR HPAC | Replacing LP Cut Out Switch for one ckt of Emerson make 15 TR HPAC Model No GLOBEL PEX2 1030 as reqd | 1 | each | vijay.londhe | 60 | |
| 26 | HP Cut Out Switch for Emerson make 15 TR HPAC | Replacing of HP Cut Out Switch for one ckt of Emerson make 15 TR HPAC Model No GLOBEL PEX2 1030 as reqd | 2 | each | vijay.londhe | 60 | |
| 27 | V belt for blower of 15 TR Emerson make HPAC unit | Replacing V belt for blower of Emerson make 15 TR HPAC unit as reqd | 4 | each | vijay.londhe | 60 | |
| 28 | 4 Pole 32 Amp Contactor for blower motor | Replacing of 4 Pole 32 Amp contactor for blower motor as reqd Make LnT Model AC 3 MCX 03 or SS | 2 | each | vijay.londhe | 60 | |
| 29 | 3 Pole 40 Amp Contactor for compressor | Replacing of 3 Pole 40 Amp Contactor for compressor as reqd Make LnT Model AC 3 or SS | 7 | each | vijay.londhe | 60 | |
| 30 | Rewinding of Blower motor rating 3 phase 415 V Induction motor 3 HP 1430 rpm | Rewinding of Blower motor of rating 3 phase 415 V Induction motor 3 HP 1430 rpm including replacing of ball bearing etc as reqd | 3 | each | vijay.londhe | 60 | |
| 31 | Condenser motor with axial fan blade | SITC of Condenser motor with axial fan blades and safety grill housing suitable for single phase 250 W 1350 RPM for 7TR HPAC unit of Emerson Make ZIEHLABEGG Transmonk or SS | 9 | each | vijay.londhe | 60 | |
| 32 | Attending defects in control Wiring | Attending defects in control Wiring making safety operational Master slave configuration for sequential running of package communication setting of all parameters etc as reqd | 1 | job | vijay.londhe | 60 | |
| 33 | Providing nitrogen pressure testing and vacuumising the entire refrigerant system | Providing nitrogen pressure for testing of leakage arresting leakage by brazing or other suitable means etc including vaccumizing dehydrating entire refrigerant system as reqd | 1 | job | vijay.londhe | 60 | |
| 34 | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd | 86 | kg | vijay.londhe | 60 | |
| 35 | Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Stulz make 7 TR HPAC | Replacing Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel suitable for Stulz make HPAC as reqd | 2 | each | vijay.londhe | 60 | |
| 36 | High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC | Replacing High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC as reqd | 1 | each | vijay.londhe | 60 | |
| 37 | LP Cut Out Switch for Stulz make 7 TR HPAC | Replacing LP Cut Out Switch for Stulz make 7 TR HPAC as reqd | 3 | each | vijay.londhe | 60 | |
| 38 | HP Cut Out Switch for Stulz make 7 TR HPAC | Replacing HP Cut Out Switch for Stulz make 7 TR HPAC as reqd | 1 | each | vijay.londhe | 60 | |
| 39 | SITC of Condenser motor with axial fan blade and safety grill | SITC of 1Ph 250 W 1350 RPM condenser motor with axial fan blades and safety grill for 7TR HPAC unit of Stulz Make ZIEHLABEGGTransmonk or SS | 7 | each | vijay.londhe | 60 | |
| 40 | Crankcase heater for scroll compressor | Replacing Crankcase heater for scroll compressor of 7 TR HPAC unit of Stulz as reqd | 2 | each | vijay.londhe | 60 | |
| 41 | SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC | SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC complete as required | 3 | each | vijay.londhe | 60 | |
| 42 | SITC of 7 TR Copeland, Model ZR108KCE scroll compressor | SITC of 7 TR Copeland Model ZR108KCE scroll compressor including removing of old compressor, pumping down refrigerant gas etc. as reqd. Rate shall be after discount for exchange of old compressor. | 7 | job | vijay.londhe | 60 | |
| 43 | Providing Nitrogen pressure testing and vacuuming the entire refrigerant system | Providing Nitrogen pressure for testing of leakage, arresting leakage by brazing or other suitable means etc. including vacuuming dehydrating entire refrigerant system as reqd. | 7 | job | vijay.londhe | 60 | |
| 44 | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd. | 151 | kg | vijay.londhe | 60 | |
| 45 | IOC Card Controller i.e. ICOM Board for Emerson make 15 TR HPAC | Replacing IOC Card controller ICOM Board suitable for Emerson make 15 TR HPAC Model No. GLOBEL PEX2 1030 as reqd. | 2 | each | vijay.londhe | 60 | |
| 46 | LP Cut Out Switch for Emerson make 15 TR HPAC | Replacing LP Cut Out Switch for one ckt of Emerson make 15 TR HPAC Model No. GLOBEL PEX2 1030 as reqd. | 1 | each | vijay.londhe | 60 | |
| 47 | HP Cut Out Switch for Emerson make 15 TR HPAC | Replacing of HP Cut Out Switch for one ckt of Emerson make 15 TR HPAC Model No. GLOBEL PEX2 1030 as reqd. | 2 | each | vijay.londhe | 60 | |
| 48 | V belt for blower of 15 TR Emerson make HPAC unit | Replacing V belt for blower of Emerson make 15 TR HPAC unit as reqd. | 4 | each | vijay.londhe | 60 | |
| 49 | 4 Pole 32 Amp, Contactor for blower motor | Replacing of 4 Pole 32 Amp contactor for blower motor as reqd. Make LnT Model AC 3, MCX 03 or SS. | 2 | each | vijay.londhe | 60 | |
| 50 | 3 Pole 40 Amp Contactor for compressor | Replacing of 3 Pole 40 Amp Contactor for compressor as reqd. Make LnT Model AC 3 or SS. | 7 | each | vijay.londhe | 60 | |
| 51 | Rewinding of Blower motor, rating 3 phase 415 V Induction motor, 3.0 HP, 1430 rpm | Rewinding of Blower motor of rating 3 phase 415 V Induction motor, 3.0 HP, 1430 rpm including replacing of ball bearing, etc. as reqd. | 3 | each | vijay.londhe | 60 | |
| 52 | Condenser motor with axial fan blade | SITC of Condenser motor with axial fan blades and safety grill housing suitable for single phase 250 W 1350 RPM for 7TR HPAC unit of Emerson. Make ZIEHLABEGG,Transmonk or SS. | 9 | each | vijay.londhe | 60 | |
| 53 | Attending defects in control Wiring | Attending defects in control Wiring, making safety operational, Master slave configuration for sequential running of package, communication, setting of all parameters, etc. as reqd. | 1 | job | vijay.londhe | 60 | |
| 54 | Providing nitrogen pressure testing and vacuumising the entire refrigerant system | Providing nitrogen pressure for testing of leakage, arresting leakage by brazing or other suitable means etc. including vaccumizing dehydrating entire refrigerant system as reqd. | 1 | job | vijay.londhe | 60 | |
| 55 | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit | Supplying and Charging of Refrigerant Gas R407 in the existing AC Package unit upto required pressure 72 psig running as per requirement as reqd. | 86 | kg | vijay.londhe | 60 | |
| 56 | Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel make suitable for Stulz make 7 TR HPAC. | Replacing Electronic Expansion Valve Driver unit EVD evolution user interface unit without display of Carel suitable for Stulz make HPAC as reqd. | 2 | each | vijay.londhe | 60 | |
| 57 | High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC. | Replacing High pressure gas Solenoid valve unit suitable for Stulz make 7 TR HPAC as reqd. | 1 | each | vijay.londhe | 60 | |
| 58 | LP Cut Out Switch for Stulz make 7 TR HPAC | Replacing LP Cut Out Switch for Stulz make 7 TR HPAC as reqd. | 3 | each | vijay.londhe | 60 | |
| 59 | HP Cut Out Switch for Stulz make 7 TR HPAC | Replacing HP Cut Out Switch for Stulz make 7 TR HPAC as reqd. | 1 | each | vijay.londhe | 60 | |
| 60 | SITC of Condenser motor with axial fan blade and safety grill | SITC of 1Ph 250 W 1350 RPM condenser motor with axial fan blades and safety grill for 7TR HPAC unit of Stulz. Make ZIEHLABEGG,Transmonk or SS | 7 | each | vijay.londhe | 60 | |
| 61 | Crankcase heater for scroll compressor | Replacing Crankcase heater for scroll compressor of 7 TR HPAC unit of Stulz as reqd. | 2 | each | vijay.londhe | 60 | |
| 62 | SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC | SITC of Precision AC display unit assembly suitable for 7TR Stulz make Precision AC complete as required. | 3 | each | vijay.londhe | 60 |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Key insights about MAHARASHTRA tender market
The eligibility requirements include being a registered entity capable of meeting the experience and turnover criteria detailed in the tender. Bidders must comply with technical specifications and submit all required documentation.
Bidders must provide certificates demonstrating past performance, OEM turnover, and compliance with any additional documentation specified in the ATC. Submissions should adhere to the required formats as specified.
Interested bidders must complete a registration process on the designated platform to submit their bids. The registration details are outlined in the documentation related to the tender.
Submissions must conform to specific formats as outlined in the tender document. Generally, common formats like PDF and MS Word are accepted, unless noted otherwise.
The technical specifications focus on high-efficiency models, such as the 7TR Copeland Model ZR108KCE compressors, blowers, and other associated components, ensuring compatibility and efficiency.
Yes, all supplied equipment and parts must comply with established quality standards to ensure reliability and efficiency, as indicated in the tender documentation.
Bidders must demonstrate compliance with all stipulated requirements outlined in the tender, including technical specifications and documentation verification.
Testing criteria will focus on ensuring that all components meet the outlined specifications and quality standards. This evaluation will generally involve inspection upon delivery.
The Earnest Money Deposit (EMD) required for this tender is 123,031, which must be submitted along with the proposal.
Post-award, the successful bidder will be required to submit a performance security, the details of which will be specified in the tender contract documents.
Payment terms will be discussed and finalized in the contract agreements following bid acceptance, details of which will be communicated via the official awarding process.
The evaluation process is based on the total value of the proposals submitted. The bidder offering the best overall value while meeting all technical and financial criteria will be favored.
Bidders may submit their proposals electronically via the official procurement platform or as specified in the documentation provided.
Key timelines include submission deadlines, bid opening dates, and validity periods. Bidders must thoroughly review the tender documentation for specific requirements.
Results will be notified to all bidders in compliance with procurement regulations, following the finalization of the evaluation process detailed in the tender documents.
MSEs may avail special benefits including exemptions from specific eligibility criteria, facilitating easier access to tender opportunities as outlined in the tender documentation.
Startups are encouraged to participate and may receive benefits such as simplified registration processes and specific guidance on meeting eligibility requirements as detailed in the document.
Yes, adherence to 'Make in India' policies is encouraged, with a focus on local content and procurement practices. Bidders are advised to comply with all related guidelines provided in the documentation.
Sign up now to access all documents
Main Document
OTHER
OTHER
BOQ
BOQ
ATC