TenderDekho Logo
GEM

Government Tender Published for Drinking Water ATM / Water Vending Machine (Version 2) in SIWAN, BIHAR

Bid Publish Date

12-Feb-2026, 3:55 pm

Bid End Date

02-Mar-2026, 4:00 pm

Location

Latest Corrigendum Available

Progress

Issue12-Feb-2026, 3:55 pm
Corrigendum26-Feb-2026
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

1

Bid Type

Two Packet Bid

Categories 4

A tender has been published for Siwan District Panchayats Drinking Water ATM / Water Vending Machine (Version 2) (Q3) in SIWAN, BIHAR. Quantity: 1 by. Submission Deadline: 02-03-2026 16: 00: 00. Check eligibility and apply.

Documents 4

GeM-Bidding-8975625.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Madhepura District Panchayats Drinking Water ATM Tender Bihar 2025 – IS 550/RCF Standards, RFID/Card, 15°C Chiller, 20 L Container Vending

Madhepura District Panchayats

MADHEPURA, BIHAR

Posted: 21 December 2025
Closed: 31 December 2025
GEM

Panchayati Raj Department Bihar Drinking Water ATM Tender East Champaran 2025 ISO 9001 Equipment

Panchayati Raj Department

EAST CHAMPARAN, BIHAR

Posted: 12 December 2025
Closed: 22 December 2025
GEM

Panchayati Raj Department Bihar Drinking Water ATM Tender East Champaran 2025 ISO 9001

Panchayati Raj Department

EAST CHAMPARAN, BIHAR

Posted: 12 December 2025
Closed: 22 December 2025
GEM

Panchayati Raj Department Bihar Drinking Water ATM Tender 2025 - Water Vending Machine Version 2 with ISO Compliance

Panchayati Raj Department

MUNGER, BIHAR

Posted: 10 December 2025
Closed: 20 December 2025
GEM

Panchayati Raj Department Bihar Drinking Water ATM Tender 2025 – IS0 ISO Requirements, 25% Quantity Variation

Panchayati Raj Department

MUNGER, BIHAR

Posted: 10 December 2025
Closed: 20 December 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
Coin / Card Acceptor / Quantity of Dispensing Water Number of Dispensing points 1, 2, 3, 4, 5, 6 Or higher
Coin / Card Acceptor / Quantity of Dispensing Water Water Dispensing using coin acceptor Yes, No
Coin / Card Acceptor / Quantity of Dispensing Water Coins accepted for payment Re.1, Rs. 2, Rs. 5, Rs.10, Rs. 20, NA
Coin / Card Acceptor / Quantity of Dispensing Water Water Dispensing using RFID/NFC card Yes, No
Coin / Card Acceptor / Quantity of Dispensing Water Mobile Wallet accepted for payment Yes, No
CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY Purification Capacity of Water ATM (LPH) 20, 50, 100, 150, 200, 250, 300, 500, 1000, 2000 Or higher
CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY Type of Operation Manual, Semi-Automatic, Automatic with Multi-Processor Integrated Control System and remotely conrolled web based Server system Or higher
CAPACITY / TYPE / WATER SOURCE / OUTLET WATER QUALITY Water Source Municipal Tap water, Surface Water, Borewell Water
TECHNOLOGY Technology Reverse Osmosis (RO), Ultra Filtration (UF), UF+RO, Nano Filtration (NF), CDI
TECHNOLOGY Anti scalant dosing pump Yes, No
TECHNOLOGY pH Correction Dosing Pump Yes, No
CONSTRUCTIONAL Raw water Storage capacity (Indicate '0' for direct connection to continuous Tap Water source) 0, 100, 200, 500, 1000, 2000, 3000, 5000, 8000, 10000 Or higher
CONSTRUCTIONAL Raw water Storage Tank Material of Construction Concrete, Mild Steel, Stainless Steel, FRP, HDPE, Poly Propylene (PP)
CONSTRUCTIONAL Location of the Raw Water Storage Tank Inside the ATM Enclosure, Under Ground, NA for Tap Water, Outside the ATM Enclosure
CONSTRUCTIONAL Treated water Storage capacity 10-20, 21-50, 51-100, 101-150, 151-200, 201-250, 251-300, 301-350, 351-400, 401-500, 501-600, 601-700, 701-800, 801-1000 Or higher
CONSTRUCTIONAL Treated water Storage Tank Material of Construction Stainless Steel 316 Gr, Stainless Steel 304 Gr, HDPE, PP Or higher
CONSTRUCTIONAL Equipped with an in-built chiller unit for providing continuous cold water of temperature around 15 degree Celcius Yes, No
CONSTRUCTIONAL In-built Chiller Tank Capacity (Liter) 10-20, 21-50, 51-100, 101-150, 151-200, 201-250, 251-300, 301-350, 351-400, 401-500, 501-600, 601-700, 701-800, 801-1000, NA Or higher
CONSTRUCTIONAL Chiller Tank Material of Construction Stainless Steel 316 Gr, Stainless Steel 304 Gr, NA Or higher
CONSTRUCTIONAL Number of Filtration steps 5, 7, 9
CONSTRUCTIONAL Provided with suitable vending place for filling container of 20 liters capacity Yes, No
DISPLAY Display of water purity parameters Yes, No
DISPLAY Display Type LED, LCD, TFT, NA Or higher
DISPLAY Backlit Display Yes, No
DISPLAY Touch Screen Display Yes, No
DISPLAY Display Size (Characters x Lines) 4 x 2 (4 Ch x 2 lines), 8 x 2 (8 Ch x 2 lines), 16 x 2 (16 Ch x 2 lines), 20 x 2 (20 Ch x 2 lines), 7" Tablet, NA
DISPLAY Display of oulet water TDS level Yes, No
DISPLAY Display of outlet water pH level Yes, No
DISPLAY Display of outlet water Temperature Yes, No
Inlet / Feed Pump to feed water from raw water storage tank to filter Inlet / Feed Pump Type Horizontal Centrifugal, Vertical Centrifugal, NA for Tap water
Inlet / Feed Pump to feed water from raw water storage tank to filter Number of Inlet / Feed Pumps 1, 2, NA
Multi Media Filter Vessels for First stage filtration for suspended particles Material Of Construction for Multi Media Filter Vessels FRP, Steel, PP Or higher
Multi Media Filter Vessels for First stage filtration for suspended particles Number of Multi Media Filter Vessels 2, 1 Or higher
Multi-Port Valve to control filtration and backwash for media filter having sand & carbon Type of Multi-Port Valve Manual, Automatic, NA
Multi-Port Valve to control filtration and backwash for media filter having sand & carbon Multi-Port Valve Material of Construction ABS, PP, NA
Multi-Port Valve to control filtration and backwash for media filter having sand & carbon Number of Multi-Port Valves 1, 2, NA
Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality Type of Anti scalent Dosing Pump Electronic diaphragm, NA
Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality Material Of Construction for Anti scalent Dosing Pump PP, ABS, NA
Anti scalent Dosing Pump to inhibit scaling of hardness salt and silica on RO Membranes, doze pH and Cl as per water quality Number of Anti scalent Dosing Pumps 1, 2, NA
pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals Type of pH Correction Pump Electronic diaphragm, NA
pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals Material Of Construction for pH Correction Dosing Pump PP, ABS, NA
pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals Number of pH Correction Dosing Pumps 1, 2, 3, NA
pH Correction Dosing Pump & Dosing Tank to dilute water with dosing chemicals Dosing Tank Material of Construction LLDPE, HDPE, NA
High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes Type of High Pressure Pump Vertical Centrifugal Pump, NA
High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes Material Of Construction for High Pressure Pump PP, SS, NA
High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes Number of High Pressure Pumps 1, 2, 3, NA Or higher
High Pressure Pump to develop required pressure for Reverse Osmosis on RO Membranes Low pressure switch for Protection of HP pump from burn-out Yes, NA
RO Pressure Vessel Type of RO Pressure Vessel Membrane housing mounted on skid - End port type, NA
RO Pressure Vessel Material Of Construction for RO Pressure Vessel FRP, SS, NA
RO Pressure Vessel Number of RO Pressure Vessels 1, 2, 3, 4, NA Or higher
Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms Material Of Construction for UV System SS, ABS, NA
Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms Number of UV Systems 1, 2, NA Or higher
Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms Number of UV Lights 1, 2, 3, 4, 5, 6, NA Or higher
Ultra Violet (UV) System to disinfect water, kill bacteria and micro-organisms Total UV Power 12 Watts, 16 Watts, 48 Watts, NA
CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash CIP Tank Yes, No
CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash CIP Tank Material of Construction HDPE, FRP, LLDPE, NA
CIP (Clean-In-Place)Tank to mix / Dilute chemicals for membrane cleaning and permeate back wash Number of CIP Tanks 1, 2, NA Or higher
Power Source Power Source AC Power Supply, AC & DC (for dispensing only) Power Supply
Power Source Power Supply 230 ±10 V AC, 415 ±10 V AC
Power Source Battery back-up time (Hours) 6, 8, 10, 12, 14, 16, 18, 20, 22, 24 Or higher
Water ATM - Enclosure Structure Rigid structure made of MS frame, Rigid structure made of SS frame(3),, Rigid structure made of G.I. frame Or higher
Water ATM - Enclosure Thickness of the frame of structure (mm) 2.5, 2 Or higher
Water ATM - Enclosure Material of Construction of Side Panels of Water ATM Stainless Steel Sheet, Galvanized Steel Sheet Or higher
Water ATM - Enclosure Side Panel Sheet Thickness (mm) 0.6, 0.8, 1, 1.2 Or higher
Water ATM - Enclosure PUF insulation of Side Panels of Water ATM With, Without Or higher
Water ATM - Enclosure PUF insulation of the door of Water ATM With, Without Or higher
Water ATM - Enclosure Provision for in-built litter space Yes, No
Water ATM - Enclosure Covered area of treatment plant enclosure (Square Foot) 2-5, 5.1-10, 10.1-15, 15.1-20, 20.1-30, 30.1-40, 40.1-50, 50.1-60, 60.1-70, 70.1-80, 80.1-90, 90.1-100, 100.1-110, 110.1-120 Or higher
Water ATM - Enclosure Shape of the Water ATM housing Cubical, Cuboidal, Hexagonal, Cylindrical
Water ATM - Enclosure Top Canopy of the Water ATM housing Flat, Sloped, Dome
Water ATM - Enclosure Headroom for the Water ATM enclosure (Foot) 7.1-8.0, 8.1-9.0, 9.1-10.0 Or higher
Water ATM - Enclosure Floor area around the Water ATM enclosure covered with anti-skid tiles Yes, No
Water ATM - Enclosure Water ATM enclosure protected with enclosed MS grill / mesh Yes, No
Installation & Commissioning / Warranty Trial Run and Training provided (inclusive in the Scope of Supply) (Days) 5, 10 Or higher
Installation & Commissioning / Warranty Warranty for storage Tanks (Year) 1, 2, 3, 4, 5 Or higher
Installation & Commissioning / Warranty Warranty for electrical motors (Year) 1, 2, 3 Or higher
Installation & Commissioning / Warranty Warranty for the filters (Year) 1, 2, 3 Or higher
Installation & Commissioning / Warranty Warranty for the system (Year) 1, 2, 3 Or higher
Test Reports Availability of Test Report from Central Govt /NABL/ILAC accredited lab to prove confirmity to specification Yes, No
Test Reports All the test reports and certificates shall furnish by the supplier to the buyer/consignee on demand Yes, No

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Past Performance

3

Bidder Turnover

4

Certificate (Requested in ATC)

5

OEM Authorization Certificate

6

OEM Annual Turnover

7

Additional Doc 1 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

2 Updates
#1

Update

26-Feb-2026

Extended Deadline

02-Mar-2026, 4:00 pm

Opening Date

02-Mar-2026, 4:30 pm

#2

Update

23-Feb-2026

Extended Deadline

26-Feb-2026, 4:00 pm

Opening Date

26-Feb-2026, 4:30 pm