Directorate Of Medical Education And Training ICU Ventilators Tender Azamgarh Uttar Pradesh 2025 ISI/ISO Standards
Directorate Of Medical Education And Training
AZAMGARH, UTTAR PRADESH
Bid Publish Date
06-Jun-2026, 11:14 am
Bid End Date
27-Jun-2026, 12:00 pm
EMD
₹6,30,000
Value
₹6,30,00,000
Location
Progress
Quantity
18
Bid Type
Two Packet Bid
Sanjay Gandhi Post Graduate Institute Of Medical Sciences Lucknow announces a tender for ICU Ventilators (V2) (Q2) in LUCKNOW, UTTAR PRADESH. Quantity: 18. Submission Deadline: 27-06-2026 12: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
ICU Ventilators (V2) (Q2)
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Directorate Of Medical Education And Training
AZAMGARH, UTTAR PRADESH
Vadodara District Panchayat
All India Institute Of Medical Sciences (aiims)
PATNA, BIHAR
Nmdc Limited
BELLARY, KARNATAKA
National Animal Resource Facility For Biomedical Research
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| PRODUCT INFORMATION | Patient Type | Adult & pediatric, Adult, Pediatric and Neonatal |
| PRODUCT INFORMATION | Type of technology | Turbine, Compressor |
| PRODUCT INFORMATION | Tidal volume in ml | (50 ml or less) to (1500 ml or more), (2 ml or less) to (1500 ml or more), (20 ml or less) to (1500 ml or more) |
| PRODUCT INFORMATION | Respiration rate, breaths/min | up to 80 or more, up to 120 or more, upto 150 or more |
| PRODUCT INFORMATION | Trigger mechanism | Pressure /flow, Both pressure and flow |
| PRODUCT INFORMATION | Inspiratory flow rate, L/min | upto 120 or more, up to 150 or more, upto 200 or more |
| PRODUCT INFORMATION | Inspiratory pressure, cm H2O | upto 50 or more, upto 80 or more |
| PRODUCT INFORMATION | IE ratio | 1:10 to 4:1, 1:6 to 3:1 |
| PRODUCT INFORMATION | Sigh breath function | Yes, No |
| PRODUCT INFORMATION | Control panel lock | Yes, No |
| PRODUCT INFORMATION | Facility for double lung ventilation | Yes, No |
| PATIENT ASSESSMENT TOOLS | Number of loops | 2 loops (P-V, F-V) with facility of saving of 1 Loops for reference, 2 loops (P-V, F-V) |
| PATIENT ASSESSMENT TOOLS | Lung recruitment tools (PV loops) / OLT (Open lung tools) | Yes, No |
| PATIENT ASSESSMENT TOOLS | Lung mechanics visualization tool | Yes, No |
| PATIENT ASSESSMENT TOOLS | Capnography/CO2 monitoring | Yes, No |
| PATIENT ASSESSMENT TOOLS | Esophageal / transpulmonary pressure monitoring | Yes, No |
| PATIENT ASSESSMENT TOOLS | APRV(Airway Pressure Release Ventilation) /Bivent/Bi level | Yes, No |
| PATIENT ASSESSMENT TOOLS | MMV(Mandatory Minute Ventilation) + PSV (Pressure Support Ventilation) /ASV( Adaptive Support Ventilation ) or ALPV(Adaptive Lung Protection Ventilation) or Automode | Yes, No |
| PATIENT ASSESSMENT TOOLS | PRVC(Pressure-Regulated Volume Control ventilation)/Auto flow | Yes, No |
| PATIENT ASSESSMENT TOOLS | High flow oxygen therapy | Yes, No |
| PATIENT ASSESSMENT TOOLS | Automatic weaning system provided | Yes, No |
| PATIENT ASSESSMENT TOOLS | Volume Support | Yes, No |
| PATIENT ASSESSMENT TOOLS | RSBI (Rapid Shallow Breathing Index) | Yes, No |
| PATIENT ASSESSMENT TOOLS | Expiratory Time constant ( Tcexp) | Yes, No |
| PATIENT ASSESSMENT TOOLS | Compliance static and/or dynamic | Yes, No |
| PATIENT ASSESSMENT TOOLS | Inspired and/or expired resistance | Yes, No |
| PATIENT ASSESSMENT TOOLS | Occlusion pressure | Yes, No |
| PATIENT ASSESSMENT TOOLS | Inspiratory and expiratory hold | Yes, No |
| PATIENT ASSESSMENT TOOLS | Spontaneous frequency | Yes, No |
| PATIENT ASSESSMENT TOOLS | Total peep, intrinsic peep, extrinsic peep | Yes, No |
| PATIENT ASSESSMENT TOOLS | Expiratory block is autoclavable and no routine calibration required | Yes, No |
| PATIENT ASSESSMENT TOOLS | Auto compensation for ET Tube | Yes, No |
| PATIENT ASSESSMENT TOOLS | Facility for automatic compliance & Leakage compensation for circuit available | Yes, No |
| PATIENT ASSESSMENT TOOLS | RS 232 out put port | Yes, No |
| PATIENT ASSESSMENT TOOLS | USB/Memory card | Yes, No |
| PATIENT ASSESSMENT TOOLS | Availability of Remote alarm/display port | Yes, No |
| PATIENT ASSESSMENT TOOLS | Facility to Report (vent alarms and patient status) | Yes, No |
| PATIENT ASSESSMENT TOOLS | HL/7 Compliant out put | Yes, No |
| PATIENT ASSESSMENT TOOLS | Type of coloured display | LED/LCD/TFT |
| PATIENT ASSESSMENT TOOLS | Display should be touch screen | Yes, No |
| PATIENT ASSESSMENT TOOLS | NIV (Non Invasive Ventilation) to be possible in all modes of ventilation available | Yes, No, NIV available in pressure targeted modes only |
| PATIENT ASSESSMENT TOOLS | Minimum Size of display (±2%) | 12, 15, 17, 18 |
| PATIENT ASSESSMENT TOOLS | Graphic display have automatic scaling facility for waves | Yes, No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Provision of UPS | Yes, No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Backup time in hrs | 1, 2, NA if not provided |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Built in air source | Air compressor (external), Turbine (In built) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Availability of stand alone compressor | Yes, No |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Compressor shall provide an oil free Medical air, with Peak output flow should be minimum 150 LPM and Air quality complying with ISO compressed air purity class | Yes, NA (for turbine) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Seller shall ensure compatibility of compressor with ventilator | Yes, NA (for Turbine) |
| HARDWARE AND ELECTRICAL REQUIREMENTS | Nebulizer with particle size less than 3 micron | Yes |
| ADDITIONAL ACCESSORIES | Humidifier: Servo controlled with digital monitoring of inspired gas temperature with heating wire | 1, 2, NA |
| WARRANTY | Warranty (years) | 3, 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
N/a
📍 GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Central Health Service Ministry Of Health And Family Welfare
📍 NEW DELHI, DELHI
All India Institute Of Medical Sciences (aiims)
📍 JODHPUR, RAJASTHAN
Central Health Service Ministry Of Health And Family Welfare
📍 NEW DELHI, DELHI
Central Health Service Ministry Of Health And Family Welfare
📍 NEW DELHI, DELHI
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS