TenderDekho Logo
Marine Engineer state-wide in Andaman & Nicobar

Marine Engineer Tenders in Andaman & Nicobar

Explore state-wide marine engineer procurement opportunities in Andaman & Nicobar. Major buyers include Indian Coast Guard and Hqids. Tender values range from ₹84K to ₹7.9 Lakh. EMD ranges from ₹15K to ₹73K. Procurement sources: Gem (60). Track active bids, eligibility criteria, and deadlines for this state.

Live Opportunities
National Reach
0

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 090

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 28 Mar
GEMService5 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 090 Main engine sea water purging Wet line Sea water leakage observed in both main engine inlets to outlet exhausts purging wet line Line to be renewed as .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 091 AC overboard line a Sea water leakage observed in overboard flange of AC system Flange to be fabricated and affixed as per sample Material Aluminium b .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 092 DD Pump Overhaul diesel driven pump and replace the worn out parts Diesel driven pump and engine to be scrapped and one coat of primer and paint to be.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; LA 5076 PA System Check all weather deck junction boxes and socket for corrosion Replace following defective components i Junction boxes 04 Nos ii Sockets 0..
Deadline
3 Apr 2025
View Details

Refine Your Search

Quick filters based on popular searches

Popular
Top States
Top Cities
Top Organizations
Sources

Click any filter to narrow down your results • Applied filters shown with opacity

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 412; H 83 W

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 3 Apr
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 412; H 83 Water jet protection cover at quarter deck deteriorated at various places Same needs to be fabricated as per sample Area 05 square meters Material AL .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 412; E 112 Exhaust fire damper flaps of both exhaust blowers at engine room found hard to rotate due to damage in shaft of the fire damper flap In details inspec.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 412; E 111 Main engine exhaust Blower trunking at engine room found crack in various place due to thin down of exhaust trunking plate Exhaust blower trunking to b.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 412; L 127 SME dynamo was unable to provide charging voltage to the starting batteries suspected charging coil of dynamo defective Defect to be rectified and pro..
Deadline
10 Apr 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-151; E 016

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 4 Apr
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-151; E 016 Sea water leakage observed view multiple pin holes from AC system pipe line Pipe line to be fabricated renewed All inway job include removal of fitted .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-151; E 017 Black water leakage observed STP pipe line view pipeline material deteriorated perished Pipeline to be renewed repaired as per sample Inway jobs includ.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-151; L 012 Navigation Communication battery cover for protection from Rain Moisture on flag deck to be fabricated Mat Al Length 100 cm Height 30CM; Service Provi.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-151; E 018 Stbd Gear box sea water cooling line a Sea water leakage observed from pin holes of stbd gear box cooler cooling pipe line pipe line to be chemically .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-151; L 013 Main broadcast not producing adequate power output from speakers suspect amplifier interface module malfunctioning Defect to be rectified and proved fo.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-151; H 023 Abnormal sound and vibration observed whilst starting Ships diving air compressor Diving air compressor to be overhauled defect to be rectified and pro.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-151; L 014 Wire-mess fencing for main engine and DAs batteries deteriorated Same to be repaired Mat AL Length 2m Height 1M; Service Provider
Deadline
11 Apr 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-418; L 046

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 5 Apr
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-418; L 046 During PDA operation it was observed that PDA dynamo was unable to provide charging voltage to the starting batteries view suspected dynamo malfunction.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-418; E 048 Sea water leakage observed in both main engine inlets to outlet exhausts purging wet line Line to be renewed as per sample length 30 mtr Dia 12 inches;.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-418; E 049 Onboard spare keeping boxes in water jet compartment and NBCD boxes on flag deck broken deteriorated To be fabricated as per sample Qty 06 nos Material.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-418; E 050 Chequered plates carpet area approx 12 mtrs in engine room and water Jet are highly rusted deteriorated All plates along with supporting base frame riv.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-418; H 033 Refabrication of following Exercises Board in Bridge Same may be fabricated as per sample Mat Wood Size 02x02x2 5 feet i Frequency & Call Sign Board .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-418; E 051 Abnormal noise observed from AHU compartment of AC plant DI DR carried out by ship staff suspect bearings are worn out Following jobs to be undertaken ..
Deadline
12 Apr 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 089

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 5 Apr
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 089 The ship is fitted 02 in number sea water collecting tray above both DAs at engine room for protect from sea water Sea water leakage observed from coll.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 067 DA emergency sea water suction line punctured and cracked at various places Same to be renewed repaired Mat SS Dia 50mm Length 2 mtr; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; H 068 Ship is fitted with 01 no water purifier make AOA The RO purifier generating hard non-drinkable water suspected RO purifier filter cartridge malfunctio.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 076 Both main engine shaft protection cover to be fabricated in engine room and silencer battery Compartment Mat Wire Mess type with supporting angle Lengt.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 093 Low air flow and ice formation observed on evaporator coil and air not cooling as per requirement of AC plant DI carried out by SS and found evaporator.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-424; E 083 Minor hydraulic oil leakage observed from eight in nos high pressure hydraulic transom flexible hoses of water jet system Requirement exists for fabric..
Deadline
12 Apr 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-416; L 095

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 10 Apr
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-416; L 095 WJ STBD exhausts blower motor getting tripped instantly after switching ON Suspect motor winding short circuited and bearing worn out Defect to be rect.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-416; L 096 Hanging support of WJ port blower found deteriorated Same to be repaired and system to be proved Mat MS; Service Provider , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-416; E 123 ER Ventilation water drain trey deteriorated Same to be renewed fabricated as per sample Mat SS Qty 04 Nos Length 2 Meter Breadth 2 Meter; Service Prov.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-416; E 124 Wire- Mess gratings of ER ventilation are deteriorated Same to be renewed fabricated as per sample Mat MS Qty 04 Nos L-2 meter B-2 Meter; Service Provid.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-416; E 125 Main engine exhaust Blower trunking at engine room found crack in various place due to thin down of exhaust trunking plate Exhaust blower trunking to .. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-416; L 097 PME dynamo was unable to provide charging voltage to the starting batteries suspected charging coil of dynamo defective Defect to be rectified and prov.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-416; E 126 Chequered plates carpet area approx-12 mtrs in engine room and water Jet are highly rusted deteriorated All plates along with supporting base frame riv.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-416; L 098 10 in nos Bunk light at Officer SO Jr Sailor cabin found defective Bunk light to be repaired and system to be proved; Service Provider
Deadline
17 Apr 2025
View Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-414; E 073

Indian Coast Guard

SOUTH ANDAMANS, ANDAMAN & NICOBARPosted 16 Apr
₹7.0 L
GEMService4 Documents
Category: Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-414; E 073 Out board motor No-1 Make Mercury Marine 40 HP OBM Model No 1040213El Sl No on 424939 The OBM reverse gear mechanism is stuck-up in position due to def.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-414; L 092 Morse Light Morse code light found defective during deployment showing internal wiring from bridge to bridge top open circuit In way jobs include remov.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-414; L 009 Walkie Talkie a crack was observed on display of one in number STV 160 Walkie Talkie set Display to be renewed repaired through competent firm and walk.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-414; E 074 Engine room and water jet checker plate Mat Aluminium area 50 Sq mtrs found wear and tear Same need to be renewed In way job include removal of old che.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-414; E 075 Both main engine shaft protection cover to be fabricated in engine room and silencer battery Compartment Mat Wire Mess type with supporting angle Lengt.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-414; H 004 Fabrication of following Exercises Board in Bridge Same may be fabricated as per sample Mat-Wood Size-02x02x25 feet i Frequency & Call Sign Board-01 No.. , Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-414; E 076 Abnormal noise observed from AHU compartment of AC plant DI DR carried out by ship staff suspect bearings are worn out Following jobs to be undertaken ..
Deadline
23 Apr 2025
View Details