Bids are Invited For Infant Warmer (V2) in SURAT, GUJARAT

Bid Publish Date

20-Feb-2026, 3:17 pm

Bid End Date

13-Mar-2026, 6:00 pm

Value

₹2,22,500

Progress

Issue20-Feb-2026, 3:17 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

5

Bid Type

Two Packet Bid

Categories 1

A tender has been published for N/a Infant Warmer (V2) (Q2) in SURAT, GUJARAT. Quantity: 5 by. Submission Deadline: 13-03-2026 18: 00: 00. Check eligibility and apply.

Documents 4

GeM-Bidding-9004454.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

JIPMER Infant Warmer Tender Pondicherry 2025 - ISI/Make in India Compliance, EMD ₹100000

Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer)

PONDICHERRY, PUDUCHERRY

Posted: 22 November 2025
Closed: 31 December 2025
GEM

Infant Warmer (V2)

Health Services

AIZAWL, MIZORAM

Posted: 1 September 2025
Closed: 19 September 2025
GEM

Jharkhand Health Department Infant Warmer Tender Hazaribag Jharkhand 2025 - V2 Q2 Specifications

N/a

HAZARIBAG, JHARKHAND

Posted: 11 November 2025
Closed: 21 November 2025
GEM

Infant Warmer (V2)

South Central Railway

HYDERABAD, TELANGANA

Posted: 10 May 2025
Closed: 20 May 2025
GEM

Infant Warmer (V2)

Hospital Medical Education

Posted: 28 May 2025
Closed: 9 June 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
GENERAL Product Description Infant Radiant Warmer
PRODUCT INFORMATION Facility to display set and observed skin temperature in degree C and heater power output separately Yes
PRODUCT INFORMATION Type of heater Ceramic / High Alloy Steel / Quartz infrared / Calrod heater
PRODUCT INFORMATION Audiovisual alarm facility Overheating beyond set temperature range, Spurt in Heater output i.e. more than 60% heater output for 10 minutes system should raise alarm and cutoff heater, Power failure, Heater failure, Patient temperature less/Greater than required/set temperature, Probe failure, Temperature Probe disconnect
PRODUCT INFORMATION Warmer head should be rotatable in different direction, so as to allow taking X-ray Yes
PRODUCT INFORMATION Observation light Luminance ≥ 1000 Lux
PRODUCT INFORMATION Setable Temperature 32 to 38 Degree C
PRODUCT INFORMATION Temperature resolution ≤ 0.1 Degree C
PRODUCT INFORMATION Temperature accuracy ≤ 0.2 Degree C
PRODUCT INFORMATION Facility to lock the keyboard to avoid unwanted user modification of the set parameters Yes
PRODUCT INFORMATION Should have a Feather Touch operation with large digital display and comprehensive alarms, Control Panel should be liquid proof and allow easy and hygienic disinfection Yes
PRODUCT INFORMATION Manual Mode can adjust Heater Output 10 -100 %, with 10% increment Yes
PRODUCT INFORMATION Height Adjustable feature Motorized, Manual, NA
PRODUCT INFORMATION Bed Distance from the heat source (in cm) 80 to 90
PRODUCT INFORMATION Lockable castor wheels Yes
PRODUCT INFORMATION Power ON Indication Yes
PRODUCT INFORMATION Provision for X-Ray cassette holder Yes
PRODUCT INFORMATION Markings on the bassinet and X-Ray cassette holder to enable proper positioning of the baby while doing the X-Ray Yes
PRODUCT INFORMATION Number of tubing ports on the side walls (For cable management) 2 to 4
PRODUCT INFORMATION Height of the side walls over the mattress (in mm) ≥ 110
PRODUCT INFORMATION Bay bed should be crevice free for ease of cleaning, infection control Yes
PRODUCT INFORMATION Mattress used should be of biocompatible material Yes
PRODUCT INFORMATION Transparent collapsible side walls easily detachable for cleaning Yes
PRODUCT INFORMATION Skin temperature probe with biocompatible baby contact material Yes
PRODUCT INFORMATION Mobility, portability on castors Yes
PRODUCT INFORMATION 2/4 of the castors should have brakes Yes
PRODUCT INFORMATION Castor size ≥ 4 inch
PRODUCT INFORMATION Tilt-able bed (10 to 12 Deg ) Lockable in position at any angle Yes
Settings Settings with facility to clearly display the selected mode Manual mode and Servo mode
Settings Provision for Set temperature range (in servo mode) 32 to 38 Degree C
Settings User's interface Manual and Servo controlled temperature regulation
Settings Display LCD/ LED
Settings Transformers of devcie shall be protected against overheating in the event of short circuit or overload of any output winding Yes
Settings Temperature on the baby mattress when the warmer is operating under steady temperature condition Not exceed 43 Degree C
Settings Temperature differences on the mattress Not exceed 2 Degree C
PHYSICAL CHARACTERISTICS Should maintain desired set temperature and uniform heat distribution in baby cradle Yes
ACCESSORIES Number of IV pole 1
ACCESSORIES Number of Storage drawer 2
ACCESSORIES Number of X- ray tray 1
ACCESSORIES Number of Mattress 1
ELECTRICAL REQUIREMENT Power Requirements 220 to 240V, 50 Hz AC, ± 10% of input
CERTIFICATIONS Certification for manufacturing unit ISO:13485 (Latest)
CERTIFICATIONS Electrical Safety Compliance Standard IEC 60601-1-2 or Equivalent BIS
WARRANTY Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) 3, 4, 5 Or higher

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Experience Criteria

2

Bidder Turnover

3

Certificate (Requested in ATC)

4

OEM Authorization Certificate

5

Additional Doc 1 (Requested in ATC)

6

Additional Doc 2 (Requested in ATC)

7

Additional Doc 3 (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

8

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer