Digital Multimeter
Durgapur Steel Plant
Bid Publish Date
08-Jul-2026, 10:21 am
Bid End Date
29-Jul-2026, 3:00 pm
Location
Progress
Quantity
12
Bid Type
Two Packet Bid
A tender has been published for Uranium Corporation Of India Limited Digital Multimeter (Q3) in EAST SINGHBHUM, JHARKHAND. Quantity: 12 by. Submission Deadline: 29-07-2026 15: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Digital Multimeter (Q3)
Payment Timelines
Payments shall be made to the Seller within 10 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
90
Delivery Locations
1
Delivery Cities
Saraikela Kharsawan
Delivery Pincodes
832107
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Sheikh Mohammed Shamim | 832107,UCIL TURAMDIH STORE UCIL TURAMDIH MINES , PO- SUNDARNAGER , DIST-EAST SINGHBHUM,JAMSHEDPUR JHARKHAND Ph no : 8789648210 | Saraikela Kharsawan | Jharkhand | 832107 | 12 | 90 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
Durgapur Steel Plant
Indian Space Research Organization
THIRUVANANTHAPURAM, KERALA
Institute For Plasma Research
N/a
GURGAON, HARYANA
Bharat Earth Movers Limited (beml)
BANGALORE, KARNATAKA
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| MEASUREMENTS | DC Voltage Range | 600.0 |
| MEASUREMENTS | DC Voltage Accuracy | 0.05 |
| MEASUREMENTS | DC Voltage resolution | 1.0 |
| MEASUREMENTS | AC Voltage Range | 600.0 |
| MEASUREMENTS | AC Voltage Accuracy | 0.5 |
| MEASUREMENTS | AC Voltage resolution | 1.0 |
| MEASUREMENTS | DC Current Range | 10.0 |
| MEASUREMENTS | DC Current Accuracy | 1.0 |
| MEASUREMENTS | DC Current resolution | 1.0 |
| MEASUREMENTS | AC Current Range | 10.0 |
| MEASUREMENTS | AC Current Accuracy | 1.0 |
| MEASUREMENTS | AC Current resolution | 1.0 |
| MEASUREMENTS | Resistance Range | 40.0 |
| MEASUREMENTS | Resistance Accuracy | 1.0 |
| MEASUREMENTS | Resistance resolution | 1.0 |
| MEASUREMENTS | Capacitance Range ( Micro farad ) | 1 to 100 |
| MEASUREMENTS | Capacitance Accuracy ( % ) | 3.5 |
| MEASUREMENTS | Capacitance resolution ( nF ) | 1 |
| MEASUREMENTS | Frequency Range ( KHz ) | 50 |
| MEASUREMENTS | Frequency Accuracy ( % ) | 1 |
| MEASUREMENTS | Frequency resolution ( Hz ) | 1 |
| MEASUREMENTS | Temperature Range ( Degree C ) | NA |
| MEASUREMENTS | Temperature Accuracy ( % ) | NA |
| MEASUREMENTS | Temperature resolution ( Degree C ) | NA |
| FEATURES | Type | Hand Held |
| FEATURES | Display (Digits) | 4.5 |
| FEATURES | Measurement Type | True RMS |
| FEATURES | Counts | 50000, 40000, 60000, 70000, 80000, 90000, 100000, 200000, 20000000 Or higher |
| OTHER FEATURES | Continuity test and Diode test | Not Available |
| OTHER FEATURES | Data logging | Not Available |
| OTHER FEATURES | If Data Logging Feature is Available, Internal Memory | NA |
| OTHER FEATURES | Computer Interface along with software | Not Available |
| SAFETY | Safety Rating | Category III 1000 V of IEC 61010. |
| SAFETY | Safety Certification | CE |
| POWER REQUIREMENTS | Power Requirements | Battery Operated |
| POWER REQUIREMENTS | if Battery Operated, then Type of Battery | Non- Rechargeable (Alkaline) |
| POWER REQUIREMENTS | if rechargeable , then chemistry of the battery | lithium ion |
| POWER REQUIREMENTS | if Non-rechargeable , then size of the battery / cell | 9-V rectangular battery |
| POWER REQUIREMENTS | number of non- rechargeable the battery / cell | 1 |
| POWER REQUIREMENTS | Suitable charger / adaptor provided | YES |
| WARRANTY | Warranty | 1.0 |
| OPERATING CONDITION | Minimum Operating Temperature | -20.0 |
| OPERATING CONDITION | Maximum Operating Condition | 50.0 |
| OPERATING CONDITION | Operating Humidity (RH) | 80.0 |
| TEST REPORT DETAILS | The equipment supplied with calibration certificate | NA |
| TEST REPORT DETAILS | conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:9000/part-3/section-5/1977 latest | No |
| TEST REPORT DETAILS | conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:9000/part-2/section-4/1977 latest | No |
| TEST REPORT DETAILS | conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH | No |
| TEST REPORT DETAILS | Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification | No |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Certificate (Requested in ATC)
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Eastern Railway
📍 MALDA, WEST BENGAL
Oil India Limited
📍 DIBRUGARH, ASSAM
Office Of Dg (mss)
📍 PANCHKULA, HARYANA
Indian Space Research Organization
📍 THIRUVANANTHAPURAM, KERALA
Central Railway
📍 THANE, MAHARASHTRA
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS