fuser assy,logic acrd,gear unit,pci express card,ups battery
Indian Army
Progress
Quantity
3035
Category
TLD Guard Slave units as per attached Specification
Bid Type
Two Packet Bid
Nuclear Power Corporation Of India Limited invites bids for TLD Guard Slave units as per attached Specification, Power supply Battery Management Module as per attached Specification, RFID Tags as per attached Specification, Switch mode power supply unit TLD_SMPS as per attached Specification, Spare TLD tag personalization unit for ETMS PCRFRW_TLD, Spare ID card personalization unit for ETMS PCRFRW_MUE, TLD Cassette White Colour as per attached specification, User console unit for ETMS, Cabinet suitable for 180 TLDs as per attached Specification in SURAT, GUJARAT. Quantity: 3035. Submission Deadline: 26-06-2026 14: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
TLD Guard Slave units as per attached Specification , Power supply Battery Management Module as per attached Specification , RFID Tags as per attached Specification , Switch mode power supply unit TLD_SMPS as per attached Specification , Spare TLD tag personalization unit for ETMS PCRFRW_TLD , Spare ID card personalization unit for ETMS PCRFRW_MUE , TLD Cassette White Colour as per attached specification , User console unit for ETMS , Cabinet suitable for 180 TLDs as per attached Specification
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
BOQ
BOQ
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Indian Army
Indian Army
DIMAPUR, NAGALAND
Nuclear Power Corporation Of India Limited
BULANDSHAHR, UTTAR PRADESH
Indian Army
WEST DELHI, DELHI
Indian Army
LUCKNOW, UTTAR PRADESH
Tender Results
Loading results...
TLD Guard Slave units as per attached Specification
TLD Guard Slave units Specification Consists of 12 sockets to place TLDs and one socket for emergency release devic, Multi-colour LED above each socket to indicate release of TLD, RS485 Interface for communication with TLD Master,ID setting facility,Size 350mm width x 100mm height with SS front plate,Power supply 12V dc, 70mA nominal (1.1A peak),Environment Temperature 0-55 Deg. C, RH 0-95%. Part No TLD_Slave
Power supply Battery Management Module as per attached Specification
Power supply Battery Management Module(Battery 12V/7Ah for power supply module) Specification This is battery management module for charging and using the battery during power failure. Part No TLD_B_Controller
RFID Tags as per attached Specification
RFID Tags Specification 1. RFID Tag Frequency 125KHz 2. Each device should have 40-bit identity number 3. Non-contact reading of Unique ID number 4. Semiconductor Chip compatibility EM4100 5. Coding & Modulation Manchester, AM 6. Shape Suitable for pasting to TLD cassette, size 35x6x6mm MAX 7. Color & Material White ABS Plastic Part No TLD_Tag
Switch mode power supply unit TLD_SMPS as per attached Specification
Switch mode power supply unit TLD_SMPS (i-2 ) for display-7numbers and TLD_SMPS (i-5 ) for power supply-6numbers specification Input supply 180- 230V ac, 50Hz, Output uninterrupted 12V dc 5A, Enclosure open module suitable for mounting inside existing cabinet Part No TLD_SMPS
Spare TLD tag personalization unit for ETMS PCRFRW_TLD
Spare TLD tag personalization unit for ETMS PCRFRW_TLD
Spare ID card personalization unit for ETMS PCRFRW_MUE
Spare ID card personalization unit for ETMS PCRFRW_MUE
TLD Cassette White Colour as per attached specification
TLD Cassette (White Colour)as per attached specification
User console unit for ETMS
User console unit for ETMS
Cabinet suitable for 180 TLDs as per attached Specification
Cabinet suitable for 180TLDs. Contains one User console with ID Card+Fingerprint based user identification, QVGA Display, Capsense keypad,Battery backed power supply. Approx Size 820W x 810 H x 110mm D
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | TLD Guard Slave units as per attached Specification | TLD Guard Slave units Specification Consists of 12 sockets to place TLDs and one socket for emergency release devic, Multi-colour LED above each socket to indicate release of TLD, RS485 Interface for communication with TLD Master,ID setting facility,Size 350mm width x 100mm height with SS front plate,Power supply 12V dc, 70mA nominal (1.1A peak),Environment Temperature 0-55 Deg. C, RH 0-95%. Part No TLD_Slave | 5 | nos | con2.gj | 90 | |
| 2 | Power supply Battery Management Module as per attached Specification | Power supply Battery Management Module(Battery 12V/7Ah for power supply module) Specification This is battery management module for charging and using the battery during power failure. Part No TLD_B_Controller | 11 | nos | con2.gj | 90 | |
| 3 | RFID Tags as per attached Specification | RFID Tags Specification 1. RFID Tag Frequency 125KHz 2. Each device should have 40-bit identity number 3. Non-contact reading of Unique ID number 4. Semiconductor Chip compatibility EM4100 5. Coding & Modulation Manchester, AM 6. Shape Suitable for pasting to TLD cassette, size 35x6x6mm MAX 7. Color & Material White ABS Plastic Part No TLD_Tag | 1,000 | nos | con2.gj | 90 | |
| 4 | Switch mode power supply unit TLD_SMPS as per attached Specification | Switch mode power supply unit TLD_SMPS (i-2 ) for display-7numbers and TLD_SMPS (i-5 ) for power supply-6numbers specification Input supply 180- 230V ac, 50Hz, Output uninterrupted 12V dc 5A, Enclosure open module suitable for mounting inside existing cabinet Part No TLD_SMPS | 13 | nos | con2.gj | 90 | |
| 5 | Spare TLD tag personalization unit for ETMS PCRFRW_TLD | Spare TLD tag personalization unit for ETMS PCRFRW_TLD | 1 | nos | con2.gj | 90 | |
| 6 | Spare ID card personalization unit for ETMS PCRFRW_MUE | Spare ID card personalization unit for ETMS PCRFRW_MUE | 1 | nos | con2.gj | 90 | |
| 7 | TLD Cassette White Colour as per attached specification | TLD Cassette (White Colour)as per attached specification | 2,000 | nos | con2.gj | 90 | |
| 8 | User console unit for ETMS | User console unit for ETMS | 2 | nos | con2.gj | 90 | |
| 9 | Cabinet suitable for 180 TLDs as per attached Specification | Cabinet suitable for 180TLDs. Contains one User console with ID Card+Fingerprint based user identification, QVGA Display, Capsense keypad,Battery backed power supply. Approx Size 820W x 810 H x 110mm D | 2 | nos | con2.gj | 90 |
Discover companies most likely to bid on this tender
Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Army
📍 DARJEELING, WEST BENGAL
Border Security Force (bsf)
Indian Army
📍 DIMAPUR, NAGALAND
Indian Army
📍 SHAHJAHANPUR, UTTAR PRADESH
Indian Air Force
📍 BIDAR, KARNATAKA
Sign up now to access all documents
Main Document
OTHER
BOQ
BOQ
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS