Ultrasound Machine (V2)
Sashastra Seema Bal (ssb)
SONITPUR, ASSAM
Progress
Quantity
1
Bid Type
Two Packet Bid
All India Institute Of Medical Sciences (aiims) invites bids for Ultrasound Machine (V2) (Q2) in JODHPUR, RAJASTHAN. Quantity: 1. Submission Deadline: 11-06-2026 15: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Ultrasound Machine (V2) (Q2)
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Sashastra Seema Bal (ssb)
SONITPUR, ASSAM
National Rural Health Mission
KANDHAMAL, ODISHA
N/a
CENTRAL DELHI, DELHI
Central Health Service Ministry Of Health And Family Welfare
NEW DELHI, DELHI
Employees State Insurance Corporation
EAST GODAVARI, ANDHRA PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Ultrasound Machine |
| Types of Probes & Features | Applications | Abdomen, Abdominal vascular, Urology, OB/GYN, Neonatal brain, Small parts (breast, thyroid, scrotal, prostate, musculoskeletal) |
| Types of Probes & Features | Convex Probe | 2.5 to 5 MHz (±2) |
| Types of Probes & Features | Microconvex probe | 4 to 8 MHz (±2) |
| Types of Probes & Features | Linear array probe | 5 to 10 MHz (±2), 3 to 12 MHz (±2), 6 to 15 MHz (±2), 6 to 18 MHz (±2) |
| Types of Probes & Features | TVS Probe | 4 to 9 MHz (±2) |
| Types of Probes & Features | Cardiac Probe | 1 to 5 MHz (±2), 5 to 9 MHz (±2) |
| Types of Probes & Features | Hockey Stick Probe | 6 to 17 MHz (±2), 6 to 13 MHz (±2), 8 to 20 MHz (±2) |
| Types of Probes & Features | Volume Convex Probe | 2.5 to 5 MHz (±2) |
| Types of Probes & Features | Volume Linear Probe | 3 to 12 MHz (±2), 6 to 15 MHz (±2), 6 to 18 MHz (±2), 5 to 10 MHz (±2), Not Provided |
| Types of Probes & Features | Volume TVS Probe | 4 to 9 MHz (±2) |
| Types of Probes & Features | Endorectal Probe | 5 to 9 MHz (±2) |
| Types of Probes & Features | E-Breast Elastography technique | Yes |
| Types of Probes & Features | E-Thyroid Elastography technique | Yes |
| Types of Probes & Features | Liver Elastography technique | Yes |
| Types of Probes & Features | Gel Warmer | Yes |
| Types of Probes & Features | Dedicated 3-D/4-D | Yes |
| Scan Modes | B-mode | Yes |
| Scan Modes | M-mode | Yes |
| Scan Modes | Contrast harmonic imaging with angio mode | Yes |
| Scan Modes | Tissue harmonic imaging mode | Yes |
| Scan Modes | Provision of Harmonic imaging in Linear Probes | Yes |
| Scan Modes | Color Doppler imaging (CDI) | Yes |
| Scan Modes | Color Doppler 3-D/4-D option | Yes |
| Scan Modes | Power Doppler imaging (PDI) | Yes |
| Scan Modes | Power Doppler 3-D/4-D option | Yes |
| Scan Modes | Continuous wave | Yes |
| Scan Modes | Pulsed wave | Yes |
| Scan Modes | Duplex mode | Yes |
| Scan Modes | Triplex mode | Yes |
| Scan Modes | Tissue Doppler imaging | Yes |
| Scan Modes | Contrast-enhanced ultrasound (CEUS) option | Yes |
| Scan Modes | Tissue synchronization, tissue velocity | Yes |
| Scan Modes | Gain control in two dimensions for additional level of flexibility for image quality control | Yes |
| Scan Modes | Probes supplied shall be in latest generation bandwidth | Yes |
| Scan Modes | Provision for higher sensitivity for low frequency doppler in all probes | Yes |
| Scan Modes | Number of channels in color doppler system | 300000 or more (if channels are being designated as digital channels) |
| Scan Modes | Live 3 D imaging in color doppler system | Yes |
| Scan Modes | Colour Doppler system with all application packages ,Quad loop for serial studies with high frame rate revies, harmonic imaging capability in all modes and integrated stress echo package digital storage and retrieval | Yes |
| Scan Modes | Number of grey shades for sharp contrast resolutions in db | 256 or more |
| Scan Modes | Colour Flow Imaging Option | Yes |
| Scan Modes | Provision of Tissue Colorization (B-Colour) for improved contrast resolution | Yes |
| Scan Modes | All application packages should be inbuilt into the system | Yes |
| Scan Modes | Cine Loop Features | Yes |
| Scan Modes | Cine Loop Memory in MB | >=100 |
| Scan Modes | Frame grabber facility for post analysis | Yes, No |
| Scan Modes | User defined system and application presets for multi-user department | Yes |
| Scan Modes | Number of transducer/probe ports | 4 or More |
| Scan Modes | System should be capable of generating real time live 3- D images | Yes |
| Scan Modes | Contrast agent imaging | Yes |
| Scan Modes | Color Doppler system with all applications package, quad loop for serial studies with high frame rate, harmonic imaging capability in all modes and digital storage and retrieval | Yes |
| Image Display and Processing | DICOM 3 Compliant | Yes |
| Image Display and Processing | Adjustable transmit focus | Yes |
| Image Display and Processing | Automated B-mode (2-D) image | Yes |
| Image Display and Processing | Automated CDI(Color Doppler Imaging) image optimization | Yes |
| Image Display and Processing | Automated PW Doppler image optimization | Yes |
| Image Display and Processing | Dynamic receive focus | Yes |
| Image Display and Processing | Grayscale levels | 256 |
| Image Display and Processing | Image magnification (zoom) | Yes |
| Image Display and Processing | Real-time image | Yes |
| Image Display and Processing | Touch Screen | Yes |
| Image Display and Processing | Monitor shall have high-resolution | Yes |
| Image Display and Processing | Provision of Tilt or Swivel monitor should be able to view in all angles and all light conditions | Yes |
| Image Display and Processing | Type of Display | LCD/LED |
| Image Display and Processing | Monitor display size (inch) | 21 or more Or higher |
| Image Display and Processing | Split screen | Twin View and Live Quad Screen, No |
| Image Display and Processing | Single/dual monitors | Single, Dual (image display and touch panel) |
| Image Display and Processing | Depth, cm | ≥30 |
| Image Display and Processing | Pre processing | Yes |
| Image Display and Processing | Post processing | Yes |
| Image Display and Processing | Selectable dynamic range (dB) | >=200, >=275 |
| Image Display and Processing | Spectrum analyzer | Yes |
| Image Display and Processing | Digital Image Storage | Yes |
| Image Display and Processing | Cine loop playback | Yes |
| Image Display and Processing | Max number frames | >=1000 |
| Image Display and Processing | Digital storage hard drive, GB | >=500 |
| Image Display and Processing | Speckle-tracking strain and strain rate | Yes |
| Image Display and Processing | Exam protocols | Yes |
| Image Display and Processing | Digital calipers | Yes |
| Image Display and Processing | Exam presets | Yes |
| Image Display and Processing | Customizable presets | Yes |
| Image Display and Processing | On-screen annotation | Yes |
| Image Display and Processing | DVD/CD Writer/ USB | Yes |
| Image Display and Processing | Flash Memory | Yes, No |
| Image Display and Processing | USB connector | Yes |
| Image Display and Processing | Facility for high definition digital acquisition, review and editing of complete patient studies | Yes |
| Image Display and Processing | Type of processor (in PC) | i7 or latest |
| Image Display and Processing | RAM capacity of PC in GB (hint: In case PC not provided put zero) | ≥ 4 |
| Image Display and Processing | Processor speed in GHz (PC) | ≥ 3 |
| Image Display and Processing | Frame Grabber incorporated(PC) | Yes, No |
| Image Display and Processing | Connectivity between USG and PC | Yes, No |
| Image Display and Processing | PC with all software inclusive interfaced with USG machine | Yes |
| Image Display and Processing | Laser Color printer provided | Yes, No |
| Image Display and Processing | Inkjet/Thermal printer provided | Yes |
| Image Display and Processing | CD/DVD/USB Produced should be playable on any system | Yes |
| Image Display and Processing | Glossy Colour Print Paper supplied | 500 sheets |
| Image Display and Processing | Dicom Interfacability Dicom to PACS | Yes |
| Image Display and Processing | Interfacability Dicom to RIS | Yes |
| Image Display and Processing | USG sytem supplied should be upgradable to next generation system on site | Yes |
| Power Requirements | Power input, VAC | 220-240VAC, 50Hz fitted with Indian plug |
| Power Requirements | Resettable over current breaker shall be fitted for protection | Yes |
| Power Requirements | Power backup | UPS, Inbuilt battery |
| Power Requirements | Back up time in minutes (minimum) | 60.0, 30.0 |
| Power Requirements | Suitable Servo Controlled Stabilizer / CVT should be provided | Yes, No |
| Certifications | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| Certifications | Availability of valid drug/Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| Certifications | Certification for manufacturing unit | ISO:13485 (Latest) |
| Certifications | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| Certifications | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| Certifications | Electrical Safety standards | IEC-60601-1-1 or equivalent BIS |
| Warranty and Maintenance | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
| Miscellaneous Requirements | OEM/Reseller shall ensure uninterrupted availability of all spares, consumables and reagents for atleast 10 years | Yes |
| Miscellaneous Requirements | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| Miscellaneous Requirements | User/Technical/Maintenance manuals to be provided in English in hard and soft copy | Yes |
| Miscellaneous Requirements | Details of equipments and procedures required for local calibration and routine maintenance to be provided and advanced maintenance task documentation also to be furnished | Yes |
| Miscellaneous Requirements | Supplier to perform installation, safety and operation checks before handover | Yes |
| Miscellaneous Requirements | Training of users in operation and basic maintenance shall be provided | Yes |
| Miscellaneous Requirements | Contact details of manufacturer, supplier and local service agent to be provided | Yes |
| Miscellaneous Requirements | Certificate of calibration from the manufacturer | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Certificate (Requested in ATC)
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Extended Deadline
11-Jun-2026, 3:00 pm
Opening Date
11-Jun-2026, 3:30 pm
Extended Deadline
10-Jun-2026, 3:00 pm
Opening Date
10-Jun-2026, 3:30 pm
Extended Deadline
25-May-2026, 3:00 pm
Opening Date
25-May-2026, 3:30 pm
Extended Deadline
22-May-2026, 3:00 pm
Opening Date
22-May-2026, 3:30 pm
Institute Of Liver And Biliary Sciences
📍 SOUTH DELHI, DELHI
N/a
Hll Lifecare Limited
📍 THIRUVANANTHAPURAM, KERALA
Ssg Hospital Vadodara
📍 VADODARA, GUJARAT
Chhattisgarh Medical Services Corporation Limited
📍 RAIPUR, CHHATTISGARH
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS