Panchayati Raj Department Bihar Drinking Water ATM Tender BeGusarai 2026 - IS 550 / 9001 Compliant Water Vending Machine
Panchayati Raj Department
BEGUSARAI, BIHAR
Bid Publish Date
07-Feb-2026, 8:28 pm
Bid End Date
27-Feb-2026, 9:00 pm
EMD
₹80,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Organization: Chhattisgarh Biotechnology Promotion Society, Gov Office, Raipur, Chhattisgarh 492001. Product: Gas Chromatograph (GC) configuration with detector options and accessory scope, including installation, testing, and training. Estimated Value: not disclosed; EMD: ₹80,000. Location: Raipur, Chhattisgarh. Category: Gas Chromatograph (GC) configuration; detectors and inlets/columns specified in the BOQ terms. Unique scope includes multiple detector inclusion decisions, compatibility with auto sampler, head space options, and safety/IEC compliance requirements. This tender emphasizes precise detector counts and column configurations, plus mandatory certification and on-site installation.
GC configuration with detector inclusions and counts
Number of FID/TCD/ECD/NPD/FTD/FPD/PID/PFPD as applicable
Inlet/Detector ports and GC can simulate multiple detectors
Number of capillary columns and type of capillary column
GC capillary column length and packed column length
Minimum detector detection level (MDL)
Maximum GC oven temperature and ramp rate
Liquid auto sampler compatibility and vial capacity
Head space sampler compatibility and carousel capacity
Pyrolyzer system compatibility for solid/liquid samples
Software features and generic connectivity
Gas supply, total cylinder capacity, and PESO-certified regulators
UL/CE compliance and EMI/EMC testing reports
Quantity adjustment up to 25% at contract; extended delivery time rules apply
Delivery and installation at Shbhash Chandra Bose Biotechnology Incubation Centre, Raipur
Mandatory OEM/OEM-certified installation, training, and testing; warranty and spares availability
GST reimbursement per bidder rate; payment schedule to be defined in contract; ensure GST compliance
Delivery to commence after order; option for extended delivery; minimum 30 days for extended period
Penalties to be defined in contract; ensure timely delivery and commissioning; warranty terms apply
Non-liquidation and no court receivership status
7+ years residual market life for offered GC equipment
OEM authorised or OEM-certified installation capability in India
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Panchayati Raj Department
BEGUSARAI, BIHAR
Amravati District Panchayats
AMRAVATI, MAHARASHTRA
N/a
PULWAMA, JAMMU & KASHMIR
Surajpur District Panchayats
Panchayati Raj Department
VAISHALI, BIHAR
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Detectors inclusive in the scope of supply (Select Only those Detectors, which are part of supply)" | Flame Ionization Detector (FID), Electron Capture Detector (ECD) |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 1 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of TCD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of ECD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 1 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of NPD/FTD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of FPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PID in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of PFPD in the System - inclusive in the scope of Supply (Select '0' if this Detector is not a part of supply)" | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Inlets GC can Simultaneously Support | 3 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Detectors (Ports) GC can Simultaneously Support | 4 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Number of Capillary Columns provided in GC - inclusive in the scope of Supply | 0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | Type of Capillary Column | NA |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Capillary Column Length (Hint:-Select '0' if Not Applicable)" | 0.0 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "Number of Packed Columns provided in GC - inclusive in the scope of Supply (Hint:-Select '0' if Not Applicable)" | 2 |
| GAS CHROMATOGRAPH (GC) CONFIGURATION | "GC Packed Column Length (Hint:-Select '0' if Not Applicable)" | 3.0 |
| PERFORMANCE | "GC Detector Minimum Detection Level (MDL) " | < 1.4 pg C/s for FID, < 4.5 fg /sec for ECD |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Maximum Operating Temperature (GC Oven) | upto 450 deg. C (2) Or higher |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Number of Oven Ramps / Plateaus for Temperature programming | 20/21 or more |
| COLUMN OVEN (GAS CHROMATOGRAPH - GC) | Temperature Ramp Rate - Maximum | 120 Deg. C/minute or better |
| PNEUMATIC CONTROL | Number of Injection Ports | 1 |
| PNEUMATIC CONTROL | Maximum Injection Port heating Temperature | upto 450 deg. C (2) Or higher |
| PNEUMATIC CONTROL | Pressure Range | upto 120 psi (2) Or higher |
| PNEUMATIC CONTROL | Pressure set point Resolution (±)(psi) | 0.001, 0.01 Or lower |
| PNEUMATIC CONTROL | Type of Sample Injection Port | Purged packed Inlet |
| PNEUMATIC CONTROL | Split Ratio | 7500:1 |
| AUTO INJECTOR / AUTO SAMPLER | Compatible Liquid Auto Sampler - inclusive in the scope of supply | No |
| AUTO INJECTOR / AUTO SAMPLER | Capacity of the Liquid Auto Sampler (Number of Vials) | 0, 15, 100, 150 Or higher |
| AUTO INJECTOR / AUTO SAMPLER | Number of Injection Ports in the Liquid Auto Sampler | 0 |
| AUTO INJECTOR / AUTO SAMPLER | Number of Channels in the Liquid Auto Sampler | 0 |
| AUTO INJECTOR / AUTO SAMPLER | Minimum Volume of the injected liquid sample | 0.0 |
| AUTO INJECTOR / AUTO SAMPLER | Maximum Volume of the injected liquid sample | 0.0 |
| AUTO INJECTOR / AUTO SAMPLER | "Liquid Auto Sampler Features (Select applicable features Only)" | NA |
| HEAD SPACE SAMPLER | Compatible Head Space Sampler- inclusive in the scope of supply | No |
| HEAD SPACE SAMPLER | Capacity of the Head Space Sampler Carousel (number of Vials) | NA |
| HEAD SPACE SAMPLER | Head Space Sampler Temperature Range | NA |
| PYROLYZER SYSTEM | Compatible Pyrolyzer System for pyrolysis of solid and liquid samples- inclusive in the scope of supply | No |
| SALIENT FEATURES OF GAS CHROMATOGRAPH (GC) | "Salient Featutes of GC (Select applicable features Only)" | Oven power turns-off automatically when the lid/door is opened |
| SOFTWARE | "Software Features (Select Applicable Features only)" | Compatible with Windows 7 or higher version operating system, Seamless integration & control of all the GC parameters, Interface with Multiple GCs through the comprehensive real-time monitoring and diagnostic software, Real time notification via advisories and indicators, Counters, Instrument diagnostics, Access to maintenance information, Access to maintenance, run and event logs |
| GENERIC | Display | Built-in Display |
| GENERIC | Connectivity interface | USB, ETHERNET |
| GENERIC | Provision to split the sample from single injection to two different detectors and get results for two detectors simultaneously | Yes |
| ACESSORIES | Gas Supply inclusive in the scope of supply | Nitrogen, Hydrogen, Argon, Zero Air |
| ACESSORIES | Capacity of Gas cylinder | 47 liters water capacity |
| ACESSORIES | Number of Cyliners of each type supplied - inclusive in the scope of supply | 1 |
| ACESSORIES | Gas cylinders certified by PESO | Yes |
| ACESSORIES | Regulator - inclusive in the scope of supply | Dual Stage Regulator |
| ACESSORIES | "Other Accessories inclusive in the scope of supply (Select only those Accessories which are part of supply)" | Gas purification panel for all Gases with moisture trap, Hydrocarbon trap & Oxygen trap, Septa for injector x 100 nos, User / Technical / Maintenance Manual |
| ENVIRONMENTAL | Minimum Operating Temperature | 0.0 - 5.0 Or lower |
| ENVIRONMENTAL | Maximum Operating Temperature | 40.0 - 65.0 Or higher |
| ENVIRONMENTAL | Operating Humidity (RH) (%) at 40 degree C | 90.0 - 95.0 Or higher |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Warranty on equipment | 1.0 |
| INSTALLATION & COMMISSIONING / WARRANTY / AVAILABILITY OF SPARES / TRAINING | Number of days onsite training provided | 5.0 |
| CERTIFICATION / TEST REPORT | "Availability of UL/CE Certificate as per IEC 61010- 1 latest - Safety requirements for electrical equipment for measurement,control, and laboratory use General requirements" | Yes |
| CERTIFICATION / TEST REPORT | Conformance to EMC/EMI as per IEC 61326-1 latest - Electrical equipment for measurement, control and laboratory use | Yes |
| CERTIFICATION / TEST REPORT | Availability of Test Reports from Central Govt / NABL approved / ILAC accredited Lab to prove conformity to the specification | No |
Discover companies most likely to bid on this tender
GST registration certificate
Permanent Account Number (PAN) card
Experience certificates for GC/analytical instrumentation supply
Financial statements (audited if available)
EMD submission receipt of ₹80,000
Technical bid documents detailing GC configuration and detectors
OEM authorisation / dealer certificate
ISO/NABL/ILAC test reports or conformity certificates
Installation, commissioning, and training plan
GST impact statement and pricing schedule
Key insights about CHHATTISGARH tender market
Bidders must submit GST, PAN, financials, and OEM authorization along with a detailed GC configuration. Provide detector counts, capillary/packed column details, MDL, oven temp, ramp rates, and compatibility with auto sampler and head space options. EMD is ₹80,000; installation by OEM-certified personnel is required.
Required documents include GST certificate, PAN, experience certificates for GC systems, financial statements, EMD receipt ₹80,000, technical bid detailing detectors, OEM authorization, conformity certificates (UL/CE, NABL/ILAC), installation/commissioning plan, and pricing schedule.
Tender requires detector inclusions to be specified; number of FID, TCD, ECD, NPD/FTD, FPD, PID, and PFPD must be declared as part of supply. Ensure compatibility with auto sampler and head space sampler, plus accurate MDL and oven ramp specifications.
Delivery terms allow an option to extend; base delivery period plus optional 25% quantity adjustments. Installation must be performed by OEM-certified personnel at Shbhash Chandra Bose Biotechnology Incubation Centre, Raipur, 492012.
Supplied GC equipment must adhere to UL/CE per IEC 61010-1 and EMC/EMI per IEC 61326-1. Conformity must be proven via NABL/ILAC-accredited test reports; provide these certificates with the bid submission.
GST will be reimbursed per actuals or the applicable rate, whichever is lower. Bidder must specify GST in pricing; payment terms align with contract, with EMD already deposited as ₹80,000.
E-nagar Palika Government Of Madhya Pradesh
📍 SHIVPURI, MADHYA PRADESH
City Municipal Council Bidar
📍 BIDAR, KARNATAKA
Indian Army
📍 GURDASPUR, PUNJAB
Ahmednagar District Panchayats
📍 AHMEDNAGAR, MAHARASHTRA
Ahmednagar District Panchayats
📍 AHMEDNAGAR, MAHARASHTRA
Sign up now to access all documents
Main Document
CATALOG Specification
ATC