Central Board of Direct Taxes Diesel Generator Tender 900 KVA Ghaziapur Uttar Pradesh 2026
Central Board Of Direct Taxes (cbdt)
BALLIA, UTTAR PRADESH
Progress
Quantity
1
Bid Type
Two Packet Bid
N/a has released a public tender for Diesel Power Generator (up to 900 KVA) (Q2) in KAMRUP, ASSAM. Quantity: 1. Submission Deadline: 07-08-2026 16: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Diesel Power Generator (up to 900 KVA) (Q2)
Advisory Bank
State Bank of India
ePBG Percentage
5%
ePBG Duration (Months)
40
Max Delivery Days
60
Delivery Locations
1
Delivery Cities
Kamrup Metro
Delivery Pincodes
782402
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Hemanta Sarma | 782402,Nazirakhat, Sonapur | Kamrup Metro | Assam | 782402 | 1 | 60 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Central Board Of Direct Taxes (cbdt)
BALLIA, UTTAR PRADESH
Central Board Of Direct Taxes (cbdt)
FATEHPUR, UTTAR PRADESH
N/a
PATHANAMTHITTA, KERALA
N/a
UDHAM SINGH NAGAR, UTTARAKHAND
E-municipalities - Eservices To Citizens And Employees Of Urban Local Bodies Of Uttar Pradesh
GORAKHPUR, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Installation Configuration | Power Generator Installation Configurations as per CPWD General Specifications for Electrical Works – Part VII (DG Set) | Fixed (Power Generators are permanently installed)" |
| Ratings | Nominal Rated Capacity (in kVA) | 125 |
| Ratings | Number of Phase | Three Phase |
| Engine | Rated Engine Power (kWm) | 110 % of the required powered at STP(Standard Temperature Pressure) i.e equal to (Nominal Rated Capacity (KVA) of power generator Any Auxilary power Consumption by the Power generator) x Power factor(0.8) / Alternator efficience Or higher |
| Engine | Type of Engine Cooling | Liquid Cooled |
| Engine | Type of Governor | Electronic Or higher |
| Engine | Number of Cylinders | 4, 6 |
| Engine | Rated Engine Speed (in RPM) | 1500 |
| Engine | Type of Fuel | High Speed Diesel (HSD) |
| Alternator | Alternator Voltage Rating | 415.0 |
| Alternator | Conformity to Indian Standard For Alternator | Generally conforming to IS:13364 (Part-2) latest (Above 20 KVA) |
| Alternator | Voltage Regulation Grade | VG 3 Or higher |
| Alternator | Alternator IP (Ingress Protection) Rating | IP 23 Or higher |
| Control Panel | Type of Control Panel | Manual Control Panel |
| Control Panel | Control Panel Location | Inside the canopy |
| Control Panel | Display Meters in Control Panel (with Appropriate Rating and Accuracy Class) - Included in Scope of Supply | Multifunctional Digital display meter (displaying Voltage, Current, Frequency, Power Factor) |
| Fuel Tank | Fuel Tank Capacity | 200.0, 230.0, 240.0, 250.0, 292.0, 300.0 |
| Fuel Tank | Number of Fuel Tank | 1 |
| Battery | Battery Type | "Low Maintenance free to IS: 14257 for high cranking performance" |
| Salient Features | Salient Features of Power Generator | Glass window on Accoustic Enclosure in front of the Control Panel, Emergency Stop outside the Accoustic Enclosure |
| Trailer | Availability of Trailer | NA for Fixed/Skid Mounted Power Generator |
| Installation Requirement | Scope of installation for diesel generating set when offered by the vendor - inclusive in the scope of supply (Part-1) | a) Installation of Power Generator when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Power Generator and its constituent parts shall be generally conforming to CPWD General Specification for Electrical Works, Part - VII - latest. b) Foundation shall be constructed by the seller. Foundation shall be of PCC type with the ratio of 4:2:1. The length and breadth of the foundation shall be 300 mm more from the respective length and breadth of the Power Generator. The height of the foundation shall be 400 mm, i.e., 200 mm below and 200 mm above the ground level. All the materials / labour required for foundation work shall be supplied by the seller. |
| Installation Requirement | Scope of installation for diesel generating set when offered by the vendor - inclusive in the scope of supply (Part-2) | c) Supply, laying and termination of interconnecting power and control cable shall be done by the seller. The cable supplied shall be ISI marked heavy duty PVC insulated, armoured cable, with PVC outer Sheath of Type ST-2 (FR Grade, Category C1), with aluminium conductor having insulation of PVC compound type -C, suitable for rated voltage upto and including 1100 volts and conforming to IS: 1554 (Part-1) latest. For 3-Phase Power Generators, 3.5 core or higher core cables shall be used. Total length of the cable supplied by the seller shall be within 30 meters for each Power Generator with manual control panel and within 60 metres for each Power Generator with AMF control panel. The current rating of the cables shall be as indicated below: 2C, 6 Sq mm for Single Phase, 3.5 & 5.0 KVA 2C, 10 Sq mm for Single Phase, 7.5 & 10 KVA 2C, 25 Sq mm for Single Phase, 15 KVA 2C, 35 Sq mm for Single Phase, 20 KVA 2C, 70Sq mm for Single Phase, 25 KVA 2C, 95Sq mm for Single Phase, 30 KVA 2C, 120Sq mm for Single Phase, 40 KVA 4C, 4 Sq mm for Three Phase, |
| Installation Requirement | Scope of installation for diesel generating set when offered by the vendor - inclusive in the scope of supply (Part-4) | e) Construction of suitable earthing station and necessary connections shall be done by the seller. All the materials / labour required for construction of earthing station shall be supplied by the seller. The total number of earthing pits/stations shall be 4, i.e., 2 for neutral and 2 for body-earthing. Netutral earthing shall be done with copper Plate and Body earthing shall be done with G.I. plate / Copper. The consignee should choose installation site in such a way that the earthing stations can be made within 10 metres of the Power Generator. Earthing station shall be typically constructed as per prevalent standard practices and shall be generally conforming to CPWD General specification for Electrical Works, Part - VII & Part - I - latest. e) Installation of Fuel Tank including foundation / stand shall be done by the seller. f)The warranty is applicable upto specified value of month/hours whichever occurs first's. |
| Installation Requirement | Above Scope of Installation for the Diesel Generating Set, when offered by the vendor, has been seen, read, understood, and agreed to Comply | Yes |
| Warranty/Services | Number of Preventive Maintenance Visits Offered in an Year During Warranty Period (Supply of all consumables is the buyer's responsibilty) | 2 |
| Test Reports | Type of lab which carried out test of complete product to prove the conformity of product specification | Certificates required as per CPCB |
Discover companies most likely to bid on this tender
Experience Criteria
Certificate (Requested in ATC)
OEM Authorization Certificate
Additional Doc 1 (Requested in ATC)
Additional Doc 2 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Southern Railway
📍 CHENNAI, TAMIL NADU
Director General Of National Cadet Corps (dgncc)
📍 GORAKHPUR, UTTAR PRADESH
State Urban Development Authority
📍 DEHRADUN, UTTARAKHAND
Inspector General Of Registration
📍 BASTI, UTTAR PRADESH
Indian Army
📍 THIRUVANANTHAPURAM, KERALA
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER