Mobile Digital Radiography System (V2)
North Western Railway
BIKANER, RAJASTHAN
Bid Publish Date
15-Jun-2026, 1:42 pm
Bid End Date
25-Jun-2026, 6:00 pm
EMD
₹1,50,000
Location
Progress
Quantity
2
Bid Type
Two Packet Bid
Public procurement opportunity for Gujarat Medical Education And Research Society (gmers) Mobile Digital Radiography System (V2) (Q2) in AHMEDABAD, GUJARAT. Quantity: 2 issued by. Submission Deadline: 25-06-2026 18: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Mobile Digital Radiography System (V2) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS
North Western Railway
BIKANER, RAJASTHAN
N/a
N/a
LUCKNOW, UTTAR PRADESH
Iocl Bongaigaon Refinery
BONGAIGAON, ASSAM
Employees State Insurance Corporation
KORBA, CHHATTISGARH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| General | Product Description | Mobile Digital Radiography System |
| General | Scope of supply | Compact, easily transportable, digital mobile radiographic unit with articulated/telescopic arm |
| Digital Detector | Radiography Mode | Digital |
| Digital Detector | Number of detector | 1 |
| Digital Detector | Detector Material | Cesium Iodide |
| Digital Detector | Detector Size | 14 inches x 17 inches(wireless ) |
| Digital Detector | Matrix size | 2kx2k |
| Digital Detector | Pixel size in µm | <=150 |
| Digital Detector | Grey Scale resolution, bits/pixel | 14 or better |
| Digital Detector | DQE at 0 LP/mm | 65% or more |
| Digital Detector | Detector should be designed and calibrated for General Radiography Purposes and must be fully integrated with the mobile unit including the controls | Yes |
| Digital Detector | Detector storage capacity | 100 images or more |
| Control panel for image acquisition | Image preview time in seconds | <=6 |
| Control panel for image acquisition | Control panel | Microprocessor controlled |
| Control panel for image acquisition | Control panel entry | Touch screen |
| Control panel for image acquisition | Display | Digital display of mAs and KV and an electronic timer |
| Control panel for image acquisition | Inbuilt console should have touch TFT screen and control | Yes |
| Control panel for image acquisition | Console should enable to view the image, and provide post processing features, using touch screen | Yes |
| Control panel for image acquisition | Post processing features | Zoom, contrast and brightness, adjustment, panning annotate, mark and reporting |
| X Ray Generator and Tubes | KV range | 40-125 or more |
| X Ray Generator and Tubes | Focal spot, mm | 0.8 - 2 |
| X Ray Generator and Tubes | Anode Type | Rotating |
| X Ray Generator and Tubes | Control Panel and X-Ray Tube | Yes |
| Tube Suspension | Type of suspension | Articulated arm |
| Tube Suspension | Collimator Type | Manual |
| Tube Suspension | Collimator rotation | ± 90 degree with on off timer |
| Ergonomics | Unit should have small foot print | Yes |
| Ergonomics | Exposure release switch | Detachable with a cord of at least 5 meters. |
| Workstation | Inbuilt work station | Yes |
| Workstation | Monitor size in inches | 12, 14 |
| Workstation | Processor | i 3, i 5 |
| Workstation | RAM in GB | 2, 4 |
| Workstation | HDD | 500 GB, 1 TB |
| Workstation | Dicom compatibility of work station | Yes |
| Workstation | Inbuilt console should have touch screen control | Yes |
| Workstation | Number of images which can be stored | 10000 or more |
| Accessories | Lead Apron | No, Yes |
| Accessories | Light weight ‘zero lead’ radiation protection aprons provided | No |
| Accessories | Thyroid shields provided | Not provided |
| Accessories | Gonadsheet Male provided | Not provided |
| Accessories | Gonad sheet Female provided | Not provided |
| Accessories | Motorized movement for complete machine | Yes, No |
| Accessories | Castor wheel | Yes |
| Accessories | Unit should have effective breaking system for parking | Yes |
| Accessories | Power Requirements | 230 V 50 HZ Single phase -16 Ampls socket |
| Accessories | Machine should run on mains as well as battery supply | Yes, No |
| Accessories | Battery charging time in hours | <=6 |
| Certifications | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| Certifications | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| Certifications | Certification for manufacturing unit | ISO:13485 (Latest) |
| Certifications | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| Certifications | Conformity to Safety Standards | IEC 60601-2-54 or equivalent BIS |
| Certifications | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| Certifications | AERB Type Approved Equipment | Yes |
| Miscellaneous Parameters | OEM/Reseller (if supplied to reseller shall ensure uninterputed availabilty of all spares for 10 years) | Yes |
| Miscellaneous Parameters | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| Miscellaneous Parameters | Demonstration of equipment and training to be provided after completing supplies before acceptance | Yes |
| Miscellaneous Parameters | Copies of reports and certifications to be furnished to buyer on demand at time of supplies | Yes |
| Miscellaneous Parameters | QA, QC and other tests as per NABH shall be carried out by OEM or authorized agency of OEM | Yes |
| Miscellaneous Parameters | Copies of all calibration and test reports to be submitted at the time of Supply of Machine | Yes |
| Warranty | Warranty in Years | 3, 4, 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Lady Hardinge Medical College New Delhi
📍 CENTRAL DELHI, DELHI
Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer)
📍 PONDICHERRY, PUDUCHERRY
Government Medical College And Hospital
📍 CHANDIGARH, CHANDIGARH
Employees State Insurance Corporation
📍 KOLLAM, KERALA
Institute Of Kidney Diseases And Research Centre
📍 AHMEDABAD, GUJARAT
Sign up now to access all documents
Main Document
CATALOG Specification
GEM_GENERAL_TERMS_AND_CONDITIONS