EEG Machine
N/a
GAUTAM BUDDHA NAGAR, UTTAR PRADESH
Progress
Quantity
1
Bid Type
Two Packet Bid
Public procurement opportunity for All India Institute Of Medical Sciences (aiims) EEG Machine (Q2) in JODHPUR, RAJASTHAN. Quantity: 1 issued by. Submission Deadline: 09-06-2026 15: 00: 00. View full details and respond.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
EEG Machine (Q2)
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
GAUTAM BUDDHA NAGAR, UTTAR PRADESH
N/a
Agartala Government Medical College
All India Institute Of Medical Sciences (aiims)
National Animal Resource Facility For Biomedical Research
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Standards | Quality system certifications of manufacturer | ISO 13485 and ISO 9001 |
| Performance Parameters | Number of input channels | 32 |
| Performance Parameters | Number of display channels | 64 |
| Performance Parameters | Analog to digital conversion | 16 Bit |
| Performance Parameters | Photo Stimulator | Xenon |
| Performance Parameters | Frequency Band range in Hz | 0.1 to 150 Hz |
| Performance Parameters | Sampling | 1024 Hz ADC |
| Performance Parameters | Time Resolution or sweep speed in mm/s | 60 |
| Performance Parameters | High definition video camera to be supplied | Yes |
| Performance Parameters | Resolution of camera in pixels | 1289 X 720 |
| Performance Parameters | Video Camera functionalities | Should be with remote control for PAN, Tilt and Zoom facilities |
| Performance Parameters | Paste / gel used in EEG to be supplied | Conductive paste of 200 gm |
| Performance Parameters | Computer to be supplied with the machine | Yes |
| Performance Parameters | Processor of computer supplied | i5 or more |
| Performance Parameters | Ram capacity in GB of computer | 8 |
| Performance Parameters | Hard Disc capacity of computer | 1 TB |
| Performance Parameters | Monitor size in inches of computer supplied | 19 or more |
| Performance Parameters | Operating system in computer supplied | Window 7 or higher versions |
| Performance Parameters | Multi media key board,Opticcal mouse and latest anti virus to be loaded with validity period of at least 3 years | Yes |
| Performance Parameters | Printer to be supplied | Color Laser Printer with wifi |
| Performance Parameters | DVD Writer | No |
| Performance Parameters | USB PORT | Yes |
| Performance Parameters | UPS to be provided | Yes |
| Performance Parameters | Backup of UPS in hrs | 1 |
| Performance Parameters | Facility with the abdomen / chest effort sensor | No |
| Software parameters | Option of compairing any segment of EEG with the current EEG by copying | Yes |
| Software parameters | Should have FFT trend analysis and 3D brain mapping | Yes with 8 channel DSA |
| Software parameters | Heart rate monitoring Facility | Yes |
| Software parameters | System should be able to monitor EEG,Aeeg,fft Power and BSR | Yes |
| Software parameters | Should have FFT power analysis ,Spectoral edge frequency ,Median frequency,BSR,IBI and should be able to display the ration of any two selected frequency bands in graphical as well as numerical mode | Yes |
| Software parameters | No of software keys provided | 1 |
| Software parameters | Supplying review station with equipment | No |
| Software parameters | Details of review station computer supplied | No (Since review station computer not supplied ) |
| Software parameters | Review station computer system features | No (Since review station computer not supplied ) |
| Software parameters | CD /DVD Writer supplied with review station computer | NA (Since review station computer notvsupplied ) |
| Software parameters | Display of review station computer | NA (Since review station computer not supplied ) |
| Software parameters | UPS Supplied with Review station computer | NA (Since review station computer not supplied ) |
| Software parameters | Facility for acquisition and review mode by split screen | No |
| Additional Accessories | Material of disc electrode | Gold plated |
| Additional Accessories | Spare EEG disc electrodes supplied with machine | 50 |
| Additional Accessories | Head cap | 1- Adult and 1-Infant |
| Additional Accessories | Number of Patient ground cable | 1 |
| Miscellaneous Parameters | Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3 |
| Miscellaneous Parameters | Number of installations of the EEG Machine machines in Central /State/PSU Govt Hospitals( Note: Seller should supply a performace certificate of the device to the buyer if demanded after placement of order) | more than 3 |
Discover companies most likely to bid on this tender
Experience Criteria
Bidder Turnover
OEM Authorization Certificate *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Sree Chitra Tirunal Institute For Medical Sciences And Technology (sctimst)
📍 THIRUVANANTHAPURAM, KERALA
N/a
📍 MUMBAI, MAHARASHTRA
Indian Army
Health Department,madhya Pradesh
📍 GWALIOR, MADHYA PRADESH
Assam Rifles
📍 EAST KHASI HILLS, MEGHALAYA
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS