Health and Family Welfare Services Department Puducherry Infant Warmer (V2) Tender 2025 – BIS/CISL ISI/IS 550 Compliant
N/a
PONDICHERRY, PUDUCHERRY
Bid Publish Date
25-Jun-2026, 11:09 am
Bid End Date
16-Jul-2026, 11:00 am
Value
₹4,00,000
Location
Progress
Quantity
4
Bid Type
Two Packet Bid
A tender has been published for Jawaharlal Institute Of Postgraduate Medical Education And Research (jipmer) Infant Warmer (V2) (Q2) in KARAIKAL, PUDUCHERRY. Quantity: 4 by. Submission Deadline: 16-07-2026 11: 00: 00. Check eligibility and apply.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Infant Warmer (V2) (Q2)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
PONDICHERRY, PUDUCHERRY
All India Institute Of Medical Sciences (aiims)
RAIPUR, CHHATTISGARH
All India Institute Of Medical Sciences (aiims)
PATNA, BIHAR
South Central Railway
N/a
BAREILLY, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Infant Radiant Warmer |
| PRODUCT INFORMATION | Facility to display set and observed skin temperature in degree C and heater power output separately | Yes |
| PRODUCT INFORMATION | User friendly touch panel control | Yes |
| PRODUCT INFORMATION | Type of heater | Ceramic / High Alloy Steel / Quartz infrared / Calrod heater |
| PRODUCT INFORMATION | Audiovisual alarm facility | Overheating beyond set temperature range, Spurt in Heater output i.e. more than 60% heater output for 10 minutes system should raise alarm and cutoff heater, Power failure, Heater failure, Patient temperature less/Greater than required/set temperature, Probe failure, Temperature Probe disconnect |
| PRODUCT INFORMATION | Warmer head should be rotatable in different direction, so as to allow taking X-ray | Yes |
| PRODUCT INFORMATION | Observation light Luminance | ≥ 1000 Lux |
| PRODUCT INFORMATION | Colour temperature | 3700K to 5100K |
| PRODUCT INFORMATION | Setable Temperature | 32 to 38 Degree C |
| PRODUCT INFORMATION | Temperature resolution | ≤ 0.1 Degree C |
| PRODUCT INFORMATION | Temperature accuracy | ≤ 0.2 Degree C |
| PRODUCT INFORMATION | Facility to lock the keyboard to avoid unwanted user modification of the set parameters | Yes |
| PRODUCT INFORMATION | Should have a Feather Touch operation with large digital display and comprehensive alarms, Control Panel should be liquid proof and allow easy and hygienic disinfection | Yes |
| PRODUCT INFORMATION | Manual Mode can adjust Heater Output 10 -100 %, with 10% increment | Yes |
| PRODUCT INFORMATION | In Manual Mode an auditory and visual alarm shall be given at least every 15 minutes | Yes |
| PRODUCT INFORMATION | Bed height from Floor (in cm) | 80 to 100 |
| PRODUCT INFORMATION | Height Adjustable feature | Manual |
| PRODUCT INFORMATION | Bed Distance from the heat source (in cm) | 80 to 90 |
| PRODUCT INFORMATION | Lockable castor wheels | Yes |
| PRODUCT INFORMATION | Power ON Indication | Yes |
| PRODUCT INFORMATION | Provision for X-Ray cassette holder | Yes |
| PRODUCT INFORMATION | Markings on the bassinet and X-Ray cassette holder to enable proper positioning of the baby while doing the X-Ray | Yes |
| PRODUCT INFORMATION | Number of tubing ports on the side walls (For cable management) | 2 to 4 |
| PRODUCT INFORMATION | Height of the side walls over the mattress (in mm) | ≥ 110 |
| PRODUCT INFORMATION | Bay bed should be crevice free for ease of cleaning, infection control | Yes |
| PRODUCT INFORMATION | Mattress used should be of biocompatible material | Yes |
| PRODUCT INFORMATION | Transparent collapsible side walls easily detachable for cleaning | Yes |
| PRODUCT INFORMATION | Skin temperature probe with biocompatible baby contact material | Yes |
| PRODUCT INFORMATION | Mobility, portability on castors | Yes |
| PRODUCT INFORMATION | 2/4 of the castors should have brakes | Yes |
| PRODUCT INFORMATION | Castor size | ≥ 4 inch |
| PRODUCT INFORMATION | Tilt-able bed (10 to 12 Deg ) Lockable in position at any angle | Yes |
| Settings | Settings with facility to clearly display the selected mode | Manual mode and Servo mode |
| Settings | Provision for Set temperature range (in servo mode) | 32 to 38 Degree C |
| Settings | User's interface | Manual and Servo controlled temperature regulation |
| Settings | Display | LCD/ LED |
| Settings | Software and/or standard of communication(where ever required) | Inbuilt software; Interruption and restoration of the power supply does not change the preset values |
| Settings | Device shall not overbalance when placed in any transport position of normal use on a 10° inclined plane from the horizontal plane | Yes |
| Settings | Transformers of devcie shall be protected against overheating in the event of short circuit or overload of any output winding | Yes |
| Settings | Temperature on the baby mattress when the warmer is operating under steady temperature condition | Not exceed 43 Degree C |
| Settings | Temperature differences on the mattress | Not exceed 2 Degree C |
| PHYSICAL CHARACTERISTICS | Overall Weight of equipment | ≥ 50 Kgs |
| PHYSICAL CHARACTERISTICS | Mattress Dimension Length | 60 Cms or more |
| PHYSICAL CHARACTERISTICS | Mattress Dimension Width | 40Cms or more |
| PHYSICAL CHARACTERISTICS | Auditory alarm shall be audible with minimum distance of 6 feet | Yes |
| PHYSICAL CHARACTERISTICS | Should maintain desired set temperature and uniform heat distribution in baby cradle | Yes |
| ACCESSORIES | Number of Skin temperature probe (Reusable) | 10 |
| ACCESSORIES | Number of Skin temperature probe (Disposable) | 50 |
| ACCESSORIES | Number of IV pole | 1 |
| ACCESSORIES | Number of Storage drawer | 2 |
| ACCESSORIES | Number of Accessory tray (Minimum weight bearing capacity of 5Kg or more) | 1 |
| ACCESSORIES | Number of X- ray tray | 1 |
| ACCESSORIES | Number of Mattress | 1 |
| ACCESSORIES | Thermal reflector to fix the skin probe to be supplied with each equipment unit | >= 50 units |
| ELECTRICAL REQUIREMENT | Power Requirements | 220 to 240V, 50 Hz AC, ± 10% of input |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Electrical Safety Compliance Standard | IEC 60601-1-2 or Equivalent BIS |
| WARRANTY | Warranty (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
National Rural Health Mission (nrhm) State Health Society
📍 VALSAD, GUJARAT
Sanjay Gandhi Post Graduate Institute Of Medical Sciences Lucknow
📍 LUCKNOW, UTTAR PRADESH
N/a
📍 CENTRAL DELHI, DELHI
Health Services
📍 AIZAWL, MIZORAM
Gujarat Medical Services Corporation Limited (gmscl)
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS