Health Services Mizoram Semi Automated Urine Analyzer Tender Mizoram 2026 Health & Family Welfare Department
Health Services
AIZAWL, MIZORAM
Bid Publish Date
09-Jul-2026, 10:26 am
Bid End Date
24-Jul-2026, 11:00 am
Value
₹4,10,000
Location
Progress
Quantity
2
Bid Type
Two Packet Bid
Kamdhenu University invites bids for Semi Automated Urine Analyzer (Q2) in BANASKANTHA, GUJARAT. Quantity: 2. Submission Deadline: 24-07-2026 11: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Semi Automated Urine Analyzer (Q2)
Payment Timelines
Payments shall be made to the Seller within 45 days of issue of consignee receipt-cum-acceptance certificate (CRAC) and on-line submission of bills (This is in supersession of 10 days time as provided in clause 12 of GeM GTC)
Max Delivery Days
45
Delivery Locations
2
Delivery Cities
Banas Kantha
Delivery Pincodes
385506
| Consignee | Address | City | State | Pincode | Quantity | Delivery Days | Additional Requirement |
|---|---|---|---|---|---|---|---|
| Jigneshkumar Manilal Patel | 385506,Sardarkrushinagar, Dantiwada, Gujarat 385506 | Banas Kantha | Gujarat | 385506 | 1 | 45 | - |
| Patel Jaydipkumar Ramanbhai | 385506,Sardarkrushinagar, Dantiwada, Gujarat 385506 | Banas Kantha | Gujarat | 385506 | 1 | 45 | - |
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Health Services
AIZAWL, MIZORAM
Health Services
AIZAWL, MIZORAM
Health Services
AIZAWL, MIZORAM
Assam Rifles
JORHAT, ASSAM
N/a
BHOPAL, MADHYA PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | Semi Automated Urine Analyzer |
| PRODUCT INFORMATION | Type of Configuration | Benchtop |
| PRODUCT INFORMATION | Type of loading | Single strip |
| PRODUCT INFORMATION | Working principle | Reflectivity and Refractivity, Photoelectric Colorimetry, Reflectance Photometry |
| PRODUCT INFORMATION | Type of sample | Urine |
| PRODUCT INFORMATION | Chemical Testing Parameters Available in the OEM Strips | Glucose, Protein, pH, Specific Gravity, Urobilinogen, Bilirubin, Ketones, Nitrites, Ascorbic Acid, Blood & Leucocytes, Microalbumin & Creatinine with ACR ratio, Protein Creatine ratio - PCR |
| PRODUCT INFORMATION | Thoughput (Number of Sample) per hour | 30 to 80 |
| PRODUCT INFORMATION | Reagent type | Strip |
| PRODUCT INFORMATION | Availability of Quality control program in system | Yes |
| PRODUCT INFORMATION | Calibration | Automatic, Calibration strips and Automatic |
| DATA MANAGEMENT AND DISPLAY | Type of user Interface | Manual, Manual and Barcode reader |
| DATA MANAGEMENT AND DISPLAY | Type of Barcode Reader | External, NA |
| DATA MANAGEMENT AND DISPLAY | Type of Patient Data Entry | Alpha-Numerical |
| DATA MANAGEMENT AND DISPLAY | Data memory(Number of patients) | 501 to 1000, >1000 |
| DATA MANAGEMENT AND DISPLAY | HIS/LIS Interface | RS232 |
| DATA MANAGEMENT AND DISPLAY | Result and worklist transmission through LIS | Yes |
| DATA MANAGEMENT AND DISPLAY | Printer Facility | Yes |
| DATA MANAGEMENT AND DISPLAY | Type of Data Management | Inbuilt system |
| DATA MANAGEMENT AND DISPLAY | Inbuilt Display | LCD/LED/TFT |
| DATA MANAGEMENT AND DISPLAY | Number of USB Port | 1, 2 |
| POWER REQUIREMENTS | Power Supply | 220 to 240 volts, single phase, 50 Hz |
| POWER REQUIREMENTS | UPS provided | Yes, No |
| POWER REQUIREMENTS | UPS Back up Time (in Minutes) | 15 Mins, NA |
| CONSUMABLES AND ACCESSORIES | Number of Reagent Strips provided with the Analyzer | 100 |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Certification for manufacturing unit | ISO:13485 (Latest) |
| CERTIFICATIONS | Availability of Test Report for each supplied batch/product as per Medical Device Rule (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Electrical safety Compliance Standard | IEC 60601 or BIS Equivalent |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 2, 3, 4, 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Kamdhenu University
📍 BANASKANTHA, GUJARAT
Kamdhenu University
📍 BANASKANTHA, GUJARAT
All India Institute Of Medical Sciences (aiims)
📍 SOUTH DELHI, DELHI
N/a
📍 KRISHNA, ANDHRA PRADESH
Ntpc Limited
📍 BHAGALPUR, BIHAR
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS