Temperature Sensor RTD PT– 100,Temperature Sensor RTD PT– 1000
Office Of Dg (aero)
BANGALORE, KARNATAKA
Bid Publish Date
27-May-2026, 10:52 am
Bid End Date
17-Jun-2026, 11:00 am
EMD
₹8,90,249
Progress
Quantity
280
Nuclear Power Corporation Of India Limited has released a public tender for 1. PT-100 strap on type RTD for 400 NB at KGS, 2. PT-100 strap on type RTD for 400 NB at KAPS, 3. PT-100 strap on type RTD for 400 NB at NAPS, 4. PT-100 strap on type RTD for 400 NB at RAPS, 5. PT-100 strap on type RTD for 500 NB at TAPS, 6. PT-100 strap on type RTD for 600 NB at TAPS, 7. PT-100 strap on type RTD for 300 NB at RAPS, 8. PT-100 strap on type RTD for 300 NB at MAPS, 9. Test strap on type RTD for 600 NB at TAPS, 10. Pt 100 simplex area temperature RTD at KGS, 11. Pt 100 simplex area temperature RTD at KAPS, 12. Pt 100 simplex area temperature RTD at NAPS, 13. Pt 100 simplex area temperature RTD at RAPS, 14. Pt 100 simplex area temperature RTD at TAPS, 15. Pt 100 simplex area temperature RTD at MAPS, 16. Pt 100 simplex area temperature RTDs at KGS. Quantity: 280. Submission Deadline: 17-06-2026 11: 00: 00. Download documents and apply online.
Tender Category
Goods
Bid To RA
No
Item Category
1. PT-100 strap on type RTD for 400 NB at KGS , 2. PT-100 strap on type RTD for 400 NB at KAPS , 3. PT-100 strap on type RTD for 400 NB at NAPS , 4. PT-100 strap on type RTD for 400 NB at RAPS , 5. PT-100 strap on type RTD for 500 NB at TAPS , 6. PT-100 strap on type RTD for 600 NB at TAPS , 7. PT-100 strap on type RTD for 300 NB at RAPS , 8. PT-100 strap on type RTD for 300 NB at MAPS , 9. Test strap on type RTD for 600 NB at TAPS , 10. Pt 100 simplex area temperature RTD at KGS , 11. Pt 100 simplex area temperature RTD at KAPS , 12. Pt 100 simplex area temperature RTD at NAPS , 13. Pt 100 simplex area temperature RTD at RAPS , 14. Pt 100 simplex area temperature RTD at TAPS , 15. Pt 100 simplex area temperature RTD at MAPS , 16. Pt 100 simplex area temperature RTDs at KGS
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
OTHER
BOQ
BOQ
OTHER
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Office Of Dg (aero)
BANGALORE, KARNATAKA
Nuclear Power Corporation Of India Limited
THANE, MAHARASHTRA
Nuclear Power Corporation Of India Limited
UTTARA KANNADA, KARNATAKA
Bharat Dynamics Limited
MEDAK, TELANGANA
Nuclear Power Corporation Of India Limited
KANCHIPURAM, TAMIL NADU
Tender Results
Loading results...
1. PT-100 strap on type RTD for 400 NB at KGS
Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at KGS. ( 18 nos for KGS 1 and 2 and 18 nos for KGS 3 and 4)
2. PT-100 strap on type RTD for 400 NB at KAPS
Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at KAPS ( KAPS 1 and 2 )
3. PT-100 strap on type RTD for 400 NB at NAPS
Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at NAPS
4. PT-100 strap on type RTD for 400 NB at RAPS
Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at RAPS (18 nos for RAPS 3 and 4 and 18 nos for RAPS 5 and 6)
5. PT-100 strap on type RTD for 500 NB at TAPS
Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 500 NB line, OD 508 mm to be supplied at TAPS (TAPS 3 and 4)
6. PT-100 strap on type RTD for 600 NB at TAPS
Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 600 NB line, OD 610 mm to be supplied at TAPS (TAPS 3 and 4)
7. PT-100 strap on type RTD for 300 NB at RAPS
Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 300 NB line, OD 323.84mm to be supplied at RAPS (RAPS 1 and 2)
8. PT-100 strap on type RTD for 300 NB at MAPS
Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 300 NB line, OD 323.84mm to be supplied at MAPS
9. Test strap on type RTD for 600 NB at TAPS
Test strap on type RTD with 6 meter MI cable and 4 meter extension cable for 600 NB line, OD 610 mm for carrying out the type tests and to be supplied at TAPS (TAPS 3 and 4)
10. Pt 100 simplex area temperature RTD at KGS
Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at KGS ( 14 nos for KGS 1 and 2, 14 nos for KGS 3 and 4 )
11. Pt 100 simplex area temperature RTD at KAPS
Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at KAPS (KAPS 1 and 2)
12. Pt 100 simplex area temperature RTD at NAPS
Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at NAPS
13. Pt 100 simplex area temperature RTD at RAPS
Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at RAPS ( 7 nos for RAPS 1 and 2, 14 nos for RAPS 3 and 4, 14nos for RAPS 5 and 6 )
14. Pt 100 simplex area temperature RTD at TAPS
Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at TAPS (TAPS 3 and 4)
15. Pt 100 simplex area temperature RTD at MAPS
Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at MAPS (MAPS 1 and 2)
16. Pt 100 simplex area temperature RTDs at KGS
Test Pt 100 simplex area temperature RTDs with MI cable and 4 meter extension cable for carrying out the type tests and to be supplied at KGS
| Item # | Title | Description | Quantity | Unit | Consignee | Delivery (Days) | Price Trends |
|---|---|---|---|---|---|---|---|
| 1 | 1. PT-100 strap on type RTD for 400 NB at KGS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at KGS. ( 18 nos for KGS 1 and 2 and 18 nos for KGS 3 and 4) | 36 | nos | dm_mm_kgs | 365 | |
| 2 | 2. PT-100 strap on type RTD for 400 NB at KAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at KAPS ( KAPS 1 and 2 ) | 18 | nos | trivedijayshree | 365 | |
| 3 | 3. PT-100 strap on type RTD for 400 NB at NAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at NAPS | 18 | nos | con.kgs.naps | 365 | |
| 4 | 4. PT-100 strap on type RTD for 400 NB at RAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 400 NB line, OD 406.4 mm to be supplied at RAPS (18 nos for RAPS 3 and 4 and 18 nos for RAPS 5 and 6) | 36 | nos | gyanmalkhatik | 365 | |
| 5 | 5. PT-100 strap on type RTD for 500 NB at TAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 500 NB line, OD 508 mm to be supplied at TAPS (TAPS 3 and 4) | 10 | nos | con.kgs.taps | 365 | |
| 6 | 6. PT-100 strap on type RTD for 600 NB at TAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 600 NB line, OD 610 mm to be supplied at TAPS (TAPS 3 and 4) | 10 | nos | con.kgs.taps | 365 | |
| 7 | 7. PT-100 strap on type RTD for 300 NB at RAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 300 NB line, OD 323.84mm to be supplied at RAPS (RAPS 1 and 2) | 9 | nos | gyanmalkhatik | 365 | |
| 8 | 8. PT-100 strap on type RTD for 300 NB at MAPS | Harsh Environment Condition qualified PT-100 strap on type RTD with 6 meter MI cable and 40 meter extension cable for 300 NB line, OD 323.84mm to be supplied at MAPS | 18 | nos | con.kgs.maps | 365 | |
| 9 | 9. Test strap on type RTD for 600 NB at TAPS | Test strap on type RTD with 6 meter MI cable and 4 meter extension cable for 600 NB line, OD 610 mm for carrying out the type tests and to be supplied at TAPS (TAPS 3 and 4) | 1 | nos | con.kgs.taps | 365 | |
| 10 | 10. Pt 100 simplex area temperature RTD at KGS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at KGS ( 14 nos for KGS 1 and 2, 14 nos for KGS 3 and 4 ) | 28 | nos | dm_mm_kgs | 365 | |
| 11 | 11. Pt 100 simplex area temperature RTD at KAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at KAPS (KAPS 1 and 2) | 14 | nos | trivedijayshree | 365 | |
| 12 | 12. Pt 100 simplex area temperature RTD at NAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at NAPS | 14 | nos | con.kgs.naps | 365 | |
| 13 | 13. Pt 100 simplex area temperature RTD at RAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at RAPS ( 7 nos for RAPS 1 and 2, 14 nos for RAPS 3 and 4, 14nos for RAPS 5 and 6 ) | 35 | nos | gyanmalkhatik | 365 | |
| 14 | 14. Pt 100 simplex area temperature RTD at TAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at TAPS (TAPS 3 and 4) | 18 | nos | con.kgs.taps | 365 | |
| 15 | 15. Pt 100 simplex area temperature RTD at MAPS | Harsh Environment Condition qualified Pt 100 simplex area temperature RTD with MI cable and 75 meter extension cable to be supplied at MAPS (MAPS 1 and 2) | 14 | nos | con.kgs.maps | 365 | |
| 16 | 16. Pt 100 simplex area temperature RTDs at KGS | Test Pt 100 simplex area temperature RTDs with MI cable and 4 meter extension cable for carrying out the type tests and to be supplied at KGS | 1 | nos | dm_mm_kgs | 365 |
Discover companies most likely to bid on this tender
Nuclear Power Corporation Of India Limited
📍 UTTARA KANNADA, KARNATAKA
Nuclear Power Corporation Of India Limited
📍 CHITTORGARH, RAJASTHAN
Bharat Heavy Electricals Limited (bhel)
📍 SAMBALPUR, ODISHA
Joint Venture Of Cil, Ntpc, Iocl, Fcil & Hfcl
📍 GORAKHPUR, UTTAR PRADESH
Dg Armed Forces Medical Service
📍 PUNE, MAHARASHTRA
Sign up now to access all documents
Main Document
OTHER
BOQ
BOQ
OTHER
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS