Entry and Mid Level Desktop Computer,Scanner (V3),Multifunction Printer (Print, Scan, Copy),Entry a
Director,agriculture & Food Production, Bhubaneswar
JAJAPUR, ODISHA
Bid Publish Date
13-Feb-2026, 5:18 pm
Bid End Date
30-Mar-2026, 3:00 pm
EMD
₹4,68,000
Location
Progress
Quantity
13
Bid Type
Two Packet Bid
N/a announces a tender for High End Multipara Monitor (V3) (Q2) in CENTRAL DELHI, DELHI. Quantity: 13. Submission Deadline: 30-03-2026 15: 00: 00. Last date to apply is approaching fast!
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Director,agriculture & Food Production, Bhubaneswar
JAJAPUR, ODISHA
Indian Army
South Central Railway
HYDERABAD, TELANGANA
Indian Army
HISAR, HARYANA
State Bank Of India (sbi)
CHENNAI, TAMIL NADU
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| Product Specifications | Type of Monitor | Pre- Configured, Modular |
| Product Specifications | Monitoring Parameters | ECG, HR, Respiration Rate, SpO2, Pulse Rate, NIBP, Temperature, IBP |
| Product Specifications | EtCO2 | Yes |
| Product Specifications | Perfusion Index | Yes |
| Product Specifications | PPV (derived value during IBP measurement) | Yes |
| Product Specifications | Length of time of full disclosure of patient data in hr | ≥ 72 Or higher |
| Product Specifications | Length of time of trending in hr | ≥ 72 Or higher |
| ECG PARAMETERS | ECG Provided | Yes |
| ECG PARAMETERS | Number of leads of ECG | 5 |
| ECG PARAMETERS | 12-Lead interpretation for ECG | Yes |
| ECG PARAMETERS | ECG Waveform number of leads display | 7, 8, 12 |
| ECG PARAMETERS | Arrhythmia detect | Yes |
| ECG PARAMETERS | Heart rate measurement range | Atleast 30 -250 bpm |
| RESPIRATION PARAMETERS | Display waveform of respiration | Yes |
| RESPIRATION PARAMETERS | Respiration rate measurement range | 0 - 100 bpm or more, 0 - 150 bpm or more |
| PULSE OXIMETERY PARAMETERS | Probe for Adult and Pediatric | Reusable |
| PULSE OXIMETERY PARAMETERS | SPO2 measurement range | 40 - 100%, 70 - 100% |
| NIBP PARAMETERS | Systolic Blood pressure monitoring range | 30 - 300 mmHg or more, 40 - 250 mmHg or more, 40 - 270 mmHg or more |
| NIBP PARAMETERS | Diastolic Blood pressure monitoring range | 10 - 200 mmHg or more, 30 - 220 mmHg or more |
| TEMPERATURE PARAMETERS | Type of probe | Skin, Rectal, Esophageal |
| IBP PARAMETERS | Number of channels for IBP | 2, 3, 4, 8 |
| ETCO2 PARAMETERS | Sensor type | Mainstream, Sidestream, Microstream, NA |
| ETCO2 PARAMETERS | Patient type | Intubated and non intubated |
| ETCO2 PARAMETERS | CO2 Measuring range ( in mmHg ) | 0 to 99 mmHg or better |
| ALARMS | Availability of Audio and visual alarms with high , medium and low intensity adjustment | Yes |
| ALARMS | Operator can set audio visual alarm levels for low or high levels of each parameter independently | Yes |
| ALARMS | Systolic BP - low and high | Yes |
| ALARMS | Diastolic BP - low and high | Yes |
| ALARMS | Mean BP - low and high | Yes |
| ALARMS | Heart rate - low and high | Yes |
| ALARMS | SPO2 - low and high | Yes |
| ALARMS | Respiratory rate - low and high | Yes |
| ALARMS | Temperature - low and high | Yes |
| ALARMS | Alarm Volume Adjustable | Yes |
| ALARMS | Activating silence of alarm | Yes |
| ALARMS | Duration of alarm silence ( in seconds ) | 120 |
| ALARMS | Cuff leakage alarm | Yes |
| ALARMS | Cuff disconnect alarm | Yes |
| ALARMS | Alarm for inflation/deflation errors | Yes |
| ALARMS | Indicator for low-battery | Yes |
| ALARMS | EtCO2 - low and high | Yes |
| ALARMS | Escalation of Alarm Priority | Yes |
| ALARMS | Sensor/ wire/probe disconnection alarm | Yes |
| NETWORK PARAMETERS | Ethernet port | Yes |
| NETWORK PARAMETERS | Hardwired | Yes |
| NETWORK PARAMETERS | Connectivity with Network printer | Yes |
| NETWORK PARAMETERS | Connectivity provision with Central Nursing Station | Yes |
| DISPLAY PARAMETERS | Display Size in inches | 10, 12, 15, 17, 19 Or higher |
| DISPLAY PARAMETERS | Traces of display | >10 |
| DISPLAY PARAMETERS | User Interface of display | Touchscreen, Touchscreen and Rotary knob Or higher |
| DISPLAY PARAMETERS | Should be able to connect to additional display | Yes |
| STANDARD ACCESSORIES | Number of IBP cables provided | 2 Reusable Cables |
| STANDARD ACCESSORIES | Number of Adult NIBP cuffs of Medium, Large, Extra large provided | 1 Set |
| STANDARD ACCESSORIES | Number of EtCO2 adapter provided | 1 each for Adult , Neonatal and Pediatric |
| POWER REQUIREMENTS | Device Earthing | Yes |
| CERTIFICATIONS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission or along with supplies as per buyer requirement | Yes |
| CERTIFICATIONS | Conformity to Electrical Safety Standards | IEC 60601 or BIS Equivalent |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover
Additional Doc 1 (Requested in ATC)
Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
N/a
📍 SOUTH ANDAMAN, ANDAMAN & NICOBAR
📍 Mohali, PUNJAB
N/a
📍 RAIPUR, CHHATTISGARH
N/a
📍 RAIPUR, CHHATTISGARH
N/a
📍 RAIPUR, CHHATTISGARH
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS