TenderDekho Logo
GEM

Invitation to Bid - Multi Gas Detector (V1) in KORAPUT, ODISHA

Bid Publish Date

30-Jan-2026, 3:14 pm

Bid End Date

27-Feb-2026, 4:00 pm

EMD

₹10,000

Latest Corrigendum Available

Progress

Issue30-Jan-2026, 3:14 pm
Corrigendum20-Feb-2026
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

2

Bid Type

Two Packet Bid

Categories 5

National Aluminium Company Limited, Bhubaneswar invites bids for Multi Gas Detector (V1) (Q2) in KORAPUT, ODISHA. Quantity: 2. Submission Deadline: 27-02-2026 16: 00: 00. Submit your proposal before the deadline.

Documents 6

GeM-Bidding-8906045.pdf

Main Document

Other Documents

OTHER

CATALOG-Specification-1

CATALOG Specification

Other Documents

OTHER

Buyer uploaded ATC document

ATC

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Multi Gas Detector (V1)

Ntpc Limited

Posted: 23 November 2024
Closed: 3 December 2024
GEM

Multi Gas Detector (V1)

North Western Railway

Posted: 22 November 2024
Closed: 3 December 2024
GEM

Multi Gas Detector (V1)

Bharat Petroleum Corporation Ltd

RANCHI, JHARKHAND

Posted: 18 January 2025
Closed: 18 February 2025
GEM

Multi Gas Detector (V1)

Nuclear Power Corporation Of India Limited

Posted: 7 November 2024
Closed: 28 November 2024
GEM

Multi Gas Detector (V1)

Indian Navy

MUMBAI, MAHARASHTRA

Posted: 6 February 2025
Closed: 5 March 2025
GEM

Technical Specifications 1 Item

Item #1 Details

View Catalog
Category Specification Requirement
TYPE/APPLICATION/TECHNOLOGY Type Portable /Handheld
TYPE/APPLICATION/TECHNOLOGY Detactable Gases Combustible Gas-Lower Explosive Limit(LEL), Oxygen(O2), Hydrosulfide(H2S), Carbon Monooxide(CO), Ammonia(NH3), Sulfur dioxide(SO2), Chlorine(CI2), Methane (CH4), Carbon Dioxide (CO2)
AREA OF USE - HAZARDOUS AREA CLASSIFICATION Area of use - Hazardous area classification Intrinsically safe for use in hazardous area classification conforming to Class I, Division I, Group A, B, C & D or Zone - 0, Group-IIA, IIB & IIC
MEASUREMENT OF Combustible Gas- Lower Explosive Limit(LEL) Measurment Range of Combustible gas(LEL) 0 -100 %
MEASUREMENT OF Combustible Gas- Lower Explosive Limit(LEL) Resolution of the Combustible gas(LEL) measurement 1 %
MEASUREMENT OF OXYGEN(O2) Measurment Range of Oxygen(O2) gas concentration 0 -25 %
MEASUREMENT OF OXYGEN(O2) Resolution of the Oxygen(O2) measurement 0.1
MEASUREMENT OF HYDROGEN SULFIDE (H2S) Measurment Range of HYDROGEN SULFIDE (H2S) gas concentration 0 -100 ppm
MEASUREMENT OF HYDROGEN SULFIDE (H2S) Resolution of the HYDROGEN SULFIDE (H2S) measurement 1 ppm
MEASUREMENT OF SELECTABLE GAS(CO/NH3/SO2/CL2 etc) Measurment Range of Selectable Gas(CO/NH3/SO2/Cl2/CH4/CO2) 0 -500 ppm, 0 to 20 ppm
MEASUREMENT OF SELECTABLE GAS(CO/NH3/SO2/CL2 etc) Resolution of the Range of Selectable Gas(CO/NH3/SO2/Cl2/CH4/CO2) measurement 0.1 ppm, 2 ppm
SAMPLING PUMP Sampling Pump Fitted with Motorized Pump with Audio and visual low flow alarm, NA
SAMPLING PUMP Remote Sampling Accessories in the scope of Supply Minimum 120 feet long sampling hose and sampling probe equipped ; Suitable Filter, NA
POWER SOURCE Power Source Rechargeable Batteries;
POWER SOURCE Battery Size Inbuilt Replaceable rechargeable Battery
POWER SOURCE Battery chemistry Li-ion
POWER SOURCE Battery capacity (mAH) 2000.0 - 10000.0 Or higher
POWER SOURCE Suitable Battery Charger operable with 230 V + 5%, 50 Hz AC inclusive in the scope of supply Yes Or higher
GENERIC Display Self-illuminating back-light digital display, LCD
GENERIC Enclsoure Protection rating IP 65, IP 66, IP 67, IP 68 Or higher
ACCESSORIES Accessories in the scope of supply Calibration cup/adaptor/calibration tubing to facilitate calibration locally, Operation Manual, Carrying case, NA
WARRANTY/SERVICE Warranty on Equipment 12, 24 Or higher
WARRANTY/SERVICE Warranty on Sensor 12, 24 Or higher
CALIBRATION CERTIFICATE Calibration Certificate issuing authority OEM Certificate
TEST REPORT Type of lab which carried out Test of Complete Product to prove the conformity of product as per specification OEM
TEST REPORT Agree to provide all relevant documents Test Reports/supporting document /reports etc to the buyer at the time of bidding or on demand Yes

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Certificate (Requested in ATC)

2

Compliance of BoQ specification and supporting document *In case any bidder is seeking exemption from Experience / Turnover Criteria

3

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Corrigendum Updates

2 Updates
#1

Update

20-Feb-2026

Extended Deadline

27-Feb-2026, 4:00 pm

Opening Date

27-Feb-2026, 4:30 pm

#2

Update

13-Feb-2026

Extended Deadline

20-Feb-2026, 4:00 pm

Opening Date

20-Feb-2026, 4:30 pm

Similar Tenders

2 found
Urgent

Hindustan Petroleum Corporation Ltd Hydrocarbon Gas Detector Tender 2026 India - HCD Open Path Detection Standards 2026

Hindustan Petroleum Corporation Ltd

📍 VADODARA, GUJARAT

Est: ₹6.2 L
⏰ Deadline: 2 days left
🛒 Type: Goods
View GEM

Toxic Gas Detector

Directorate Of Purchase And Stores

📍 MUMBAI, MAHARASHTRA

⏰ Deadline: 4 weeks left
🛒 Type: Goods
View GEM