Power Quality Analyzer
Office Of Dg (mss)
HYDERABAD, TELANGANA
Bid Publish Date
30-Jun-2026, 11:43 am
Bid End Date
11-Jul-2026, 12:00 pm
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Hqids announces a tender for Power Quality Analyzer (Q3) in WEST DELHI, DELHI. Quantity: 1. Submission Deadline: 11-07-2026 12: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
Yes
Item Category
Power Quality Analyzer (Q3)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS
Office Of Dg (mss)
HYDERABAD, TELANGANA
Indian Air Force
SONITPUR, ASSAM
Indian Institute Of Technology (iit)
MEDAK, TELANGANA
Northern Railway
LUDHIANA, PUNJAB
Vishwakarma Government Engineering College Chandkheda Gandhinagar
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| PERFORMANCE FEATURES | Type of Power analyzer | Three phase |
| PERFORMANCE FEATURES | Number of Current Channels (Nos.) | 4 |
| PERFORMANCE FEATURES | Number of Voltage Channels | 4 |
| PERFORMANCE FEATURES | Measurable voltage range | 1000.0 |
| PERFORMANCE FEATURES | Measurable voltage accuracy | 0.1 |
| PERFORMANCE FEATURES | Measurable voltage resolution | 0.1 |
| PERFORMANCE FEATURES | Measurable current range (with clamp) | 6000.0 |
| PERFORMANCE FEATURES | Measurable current accuracy (%) | ±0.1 |
| PERFORMANCE FEATURES | Measurable current resolution | 0.1 |
| PERFORMANCE FEATURES | Maximum power that can be measured (KW) | 400.0 |
| PERFORMANCE FEATURES | Power Accuracy (%) | ±1.5 |
| PERFORMANCE FEATURES | Power resolution | 1.0 |
| MEASUREMENT FEATURES | Facility to Measure Inter harmonics | Available |
| MEASUREMENT FEATURES | Order(n) to which Facility to Measure Harmonics available | upto 50th |
| MEASUREMENT FEATURES | Facility to Measure Power Factor | Available |
| MEASUREMENT FEATURES | Accuracy in measurement of Power Factor (%) | 0.1 |
| MEASUREMENT FEATURES | Facility to Measure Distortion Factor | Not-Available |
| MEASUREMENT FEATURES | Accuracy in measurement of Distortion Factor (%) | NA |
| MEASUREMENT FEATURES | Facility to Measure Ripple Factor | Not-Available |
| MEASUREMENT FEATURES | Accuracy in measurement of Ripple Factor (%) | NA |
| MEASUREMENT FEATURES | Facility to Measure crest factor | Available |
| MEASUREMENT FEATURES | Measurable crest factor range | 1 TO 10 |
| MEASUREMENT FEATURES | Measurable crest factor accuracy (%) | 5 |
| MEASUREMENT FEATURES | Measurable crest factor resolution | 0.01 |
| MEASUREMENT FEATURES | Facility to Measure sag(dips) and swell(surge) | Available |
| MEASUREMENT FEATURES | Pattern of measurement of sag(dips) and swell(surge) | Waveform |
| MEASUREMENT FEATURES | Accuracy in measurement of Total Harmonics distortion | 2.0 |
| MEASUREMENT FEATURES | Facility to Measure voltage and current unbalance | Available |
| MEASUREMENT FEATURES | Facility to Measure inrush current | Available |
| MEASUREMENT FEATURES | Facility to Measure flicker | Available |
| DISPLAY | Display type | TFT |
| DISPLAY | Display Mode | Waveform, Meter Reading, Bar graph, Vector, digital reading |
| GENERIC | Data transfer software provided for analysis on PC | Yes |
| GENERIC | Provision for external SD Card | no |
| GENERIC | Interface | LAN, USB |
| GENERIC | Internal Memory (GB) | 4 |
| POWER SOURCE/BATTERY | Power Supply | Battery operated, 230 V AC +/- 10%,50Hz |
| POWER SOURCE/BATTERY | If battery operated, chemistry of the rechargeable battery | lithium ion |
| POWER SOURCE/BATTERY | Suitable charger / adaptor provided | yes |
| POWER SOURCE/BATTERY | Battery backup (hours) | 6 |
| OPERATING CONDITION | Minimum Operating Temperature | 0.0 |
| OPERATING CONDITION | Maximum Operating Temperature | 40.0 |
| OPERATING CONDITION | Operating Humidity (%) | 90.0 |
| SAFETY | Category of safety rating | Category III 1000 V of IEC 61010. |
| TEST REPORT DETAILS & TESTS | conformity to Dry Heat for 16 hours at a specified maximum temp in accordance with IS:9000/part-3/section-5/1977 latest | no |
| TEST REPORT DETAILS & TESTS | conformity to Cold Test for 4 hours at a specified minimum temp in accordance with IS:9000/part-2/section-4/1977 latest | no |
| TEST REPORT DETAILS & TESTS | conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH | no |
| TEST REPORT DETAILS & TESTS | Availability of Test Reports from Central Govt/NABL approved/ILAC accredited lab to prove conformity to the specification | no |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Indian Air Force
📍 JAIPUR, RAJASTHAN
Hindustan Aeronautics Limited (hal)
📍 Rangareddi, TELANGANA
Kamdhenu University
📍 JAMNAGAR, GUJARAT
Chittaranjan Locomotive Works
📍 BARDHAMAN, WEST BENGAL
Directorate Of Employment & Training
📍 SURAT, GUJARAT
Sign up now to access all documents
Main Document
CATALOG Specification
OTHER
GEM_GENERAL_TERMS_AND_CONDITIONS