GEM

Open Tender for High Mast Lighting Tower for large area with LED Flood Lighting System,XLPE Cable for Working Volta in RAISEN, MADHYA PRADESH

Bid Publish Date

19-Jan-2026, 2:15 pm

Bid End Date

09-Feb-2026, 3:00 pm

EMD

₹16,500

Progress

Issue19-Jan-2026, 2:15 pm
AwardPending
Explore all 4 tabs to view complete tender details

Quantity

404

Category

High Mast Lighting Tower for large area with LED Flood Lighting System

Bid Type

Two Packet Bid

Urban Administration And Devlopment invites bids for High Mast Lighting Tower for large area with LED Flood Lighting System (Q3), XLPE Cable for Working Voltages up to and Including 1. 1 KV as per IS 7098 (Part 1) (Q2) in RAISEN, MADHYA PRADESH. Quantity: 404. Submission Deadline: 09-02-2026 15: 00: 00. Submit your proposal before the deadline.

Documents 4

GeM-Bidding-8853514.pdf

Main Document

CATALOG-Specification-1

CATALOG Specification

CATALOG-Specification-2

CATALOG Specification

GEM General Terms and Conditions Document

GEM_GENERAL_TERMS_AND_CONDITIONS

Past Similar Tenders (Historical Results)

5 found

Rural Development Department Uttar Pradesh High Mast Lighting Octagonal Tower for Small Area with LED Flood Lighting System Tender 2026

N/a

AZAMGARH, UTTAR PRADESH

Posted: 6 January 2026
Closed: 19 January 2026
GEM

Rural Development Department Uttar Pradesh High Mast Lighting Octagonal Tower for Small Area with LED Flood Lighting System Tender 2026

N/a

AZAMGARH, UTTAR PRADESH

Posted: 6 January 2026
Closed: 19 January 2026
GEM

Rural Development Department Uttar Pradesh High Mast Lighting Octagonal Tower with LED Flood Lighting System Tender 2026

N/a

AZAMGARH, UTTAR PRADESH

Posted: 6 January 2026
Closed: 19 January 2026
GEM

Rural Development Department Uttar Pradesh High Mast Lighting Octagonal Tower LED Flood Lighting System V2 Tender 2026

N/a

AZAMGARH, UTTAR PRADESH

Posted: 6 January 2026
Closed: 19 January 2026
GEM

High Mast Lighting Octagonal Tower for Small area with LED Flood Lighting System (V2)

Rural Development Department

PURNIA, BIHAR

Posted: 7 January 2026
Closed: 17 January 2026
GEM

Technical Specifications 2 Items

Item #1 Details

View Catalog
Category Specification Requirement
GENERIC Height of High Mast Tower (in Meters) 16
GENERIC Installation and commissioning (Installation and commissioning work at multiple locations shall follow as per the guidelines of State/Central Govt rules and regulations as applicable) Yes. Including Civil work at site, Yes. Excluding Civil work, No, Yes. Including civil work for mining sites (for mining sites all Electricalss, winch mechanism, lamps control-gears, breakers, cables etc shall be suitable for 230 V (L-L), 50 Hz supply and with RCCB/ELCB based protection provided with suitable range to comply relevant CEA regulation 42
GENERIC Onsite warranty (in Years) 2, 3, 5
High mast System No of sections 2, 3, 4, 5, 6
High mast System Effective length of each section (in m) 10, 10.5, 8.5, 5
High mast System Material construction: The mast shall be manufactured using special steel plates, conforming to 355 gradeasper BSEN10 025
High mast System Bottom diameter (in mm) - Minimum 610, 540, 570
High mast System Plate thickness for Middle (in mm) - Minimum 4
High mast System Plate thickness for Bottom (in mm) - Minimum 5, 6
High mast System No of longitudinal welds / section (in Nos) 1, 2
High mast System Diameter of base plate (in mm) - Minimum 840, 740, 770
High mast System Thickness of base plate (in mm) - Minimum 30, 25
Wind Load Maximum Wind load 47 m/sec, 50 m/sec, 55 m/sec, 62.5 m/sec
Door Opening Size of opening and closing door at base compartment of high mast (in mm) - Minimum 1200 x 250, 1200 x 300
Junction Box Ingress protection for Junction Box i.e. IP Class (as per IS/IEC:60529:2001 latest) Test Report from Central Government lab/NABL/ILAC accrediated lab and report shall furnish to buyer on demand IP 55, IP 65
Junction Box No of core 3, 4, 5
Junction Box Cable category FR, FR-LSH, 1, 2
Junction Box Size of cable (in Sq mm) 1.5, 2.5, 4
Junction Box Conductor material shall be Copper
Winch The winch shall have provision for manual operation in case of failure of the motor Yes
Stainless Steel Wire Rope The breaking load of each rope shall be at full load as per the relevant standard >/=2400 Kg, >/=2250Kg
Electrical System, Cable and Cable Connections No. of cores 1, 2, 3, 4, 5
Electrical System, Cable and Cable Connections Cable shall be Armoured, Unarmoured
Electrical System, Cable and Cable Connections Conudctor material shall be Copper, Aluminium
Electrical System, Cable and Cable Connections Cable Category 1, C1, C2
Electrical System, Cable and Cable Connections Incoming power cable from feeder panel to base compartment of mast and cable shall conforming to IS:7098 (Part 1):1988 latest
Feeder pillar Panel Feeder pillar panel for each mast Yes, No without feeder pillar panel
Feeder pillar Panel Feeder panel shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz, AC, 230 V, 1 phase, AC 50 Hz, 230 V (L-L), 3 phase, AC 50 Hz (for Mining area)for Mining sites all electricals, winch mechanism, lamps control-gears, breakers, cables etc shall be suitable for 230V(L-L), 50 Hz supply
Feeder pillar Panel The control panels shall be Stand mounted, No without feeder pillar panel
Feeder pillar Panel Ingress protection for feeder pillar panel i.e IP Class (as per IS/IEC:60529:2001 latest).Test Report shall furnish from Central Government lab/NABL/ILAC accrediated lab to buyer on demand IP 55, IP 65, No without feeder pillar panel
Feeder pillar Panel It shall be fabricated out of 14 SWG CRCA sheet steel, No without feeder pillar panel
Feeder pillar Panel Thickness of sheet (in mm) 2, No without feeder pillar panel
Feeder pillar Panel The panels shall be given pre-treatment and powder coated and color shall be Grey, No without feeder pillar panel
Feeder pillar Panel The stand shall be painted in Black color, No without feeder pillar panel
Feeder pillar Panel Cable entry shall be at the Bottom, No without feeder pillar panel
Feeder pillar Panel The panels shall have knock outs of the required cable, No without feeder pillar panel
Feeder pillar Panel Laminated circuit diagram shall be pasted inside of the door, No without feeder pillar panel
Feeder pillar Panel Feeder pillar shall have pad locking arrangement Yes, No without feeder pillar panel
Feeder pillar Panel Earth terminal 12 mm dia. Bolts, No without feeder pillar panel
Feeder pillar Panel Panel shall have a sloping cover to avoid accumulation of dust Yes, No without feeder pillar panel
Feeder pillar Panel Panel shall be provided with incoming & outgoing MCCB / MCB of appropriate rating and in desired quantity depending on total no of circuits in use yes, No without feeder pillar panel
Feeder pillar Panel Timer for automatic ON & OFF of lights with pilot lamps shall be provided Yes, No without feeder pillar panel
Feeder pillar Panel Bus bars material Yes. Copper, No without feeder pillar panel
Feeder pillar Panel No of Cores 1, 2, 3, 4, 5, No without feeder pillar panel
Feeder pillar Panel Size of cable (in Sq.mm) 1.5, 2.5, 4, 6, 10, 16, No without feeder pillar panel
Feeder pillar Panel Cable Shall be Armoured, Unarmoured, No without feeder pillar panel
Feeder pillar Panel The conductor material shall be Copper, Aluminium, No without feeder pillar panel
Feeder pillar Panel cable category 1, C1, C2, No without feeder pillar panel
LED FLOOD LIGHT LUMINAIRE No. of Luminaires for each high mast lighting tower (in Nos) 12
LED FLOOD LIGHT LUMINAIRE LED Rating/System Wattage/Rated Power for each luminaire 200W
LED FLOOD LIGHT LUMINAIRE Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt
LED FLOOD LIGHT LUMINAIRE Ingress Protection (IP Rating) as per IS:10322 (Part 1):1982 latest IP65, IP66, IP67
LED FLOOD LIGHT LUMINAIRE Mounting brackets (included) Adjustable
LED FLOOD LIGHT LUMINAIRE Input operating Voltage range and frequency 90 to 300 Volts AC at 50Hz+/-2Hz, 140 to 270 Volts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V
LED FLOOD LIGHT LUMINAIRE Rated voltage 230 V AC 50 Hz, 415+/-10% V AC 50 Hz +/-5%
LED FLOOD LIGHT LUMINAIRE Colour temperature 6000K (+/- 500K), 5000K (+/- 500K), 4000K (+/- 500K), 3000K (+/- 500K)
LED FLOOD LIGHT LUMINAIRE Optic lense material (UV stabilised) (Write NA for without optic lense supply) Poly carbonate lense, NA
LED FLOOD LIGHT LUMINAIRE Operating temperature range -20 deg C to +50 deg C, -10 deg C to +50 deg C, -10 deg C to +55 deg C
LED FLOOD LIGHT LUMINAIRE The luminaire shall be protected against surges and transients( Internal) >/=5KV, >/=4KV
LED FLOOD LIGHT LUMINAIRE Number of electronic control gear per luminaire (power supplies) 1 No., 2 Nos., 3 Nos., 4 Nos.
LED FLOOD LIGHT LUMINAIRE Length of ISI marked three core wire (shall be provided along with supply of material) 50 cm, 100 cm

🤖 AI-Powered Bidder Prediction

Discover companies most likely to bid on this tender

Live AI
Historical Data

Required Documents

1

Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria

2

the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer

Similar Tenders

5 found

XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1)

Central Railway

📍 JALGAON, MAHARASHTRA

⏰ Deadline: 2 months left
🛒 Type: Goods
View GEM

XLPE Cables for Working Voltages From 3.3 KV up to and Including 33 KV as per IS 7098 (Part 2)

Central Railway

📍 JALGAON, MAHARASHTRA

EMD: ₹85,560
⏰ Deadline: 4 weeks left
🛒 Type: Goods
View GEM

XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1)

Chittaranjan Locomotive Works

📍 BARDHAMAN, WEST BENGAL

EMD: ₹2.0 L
⏰ Deadline: 4 weeks left
🛒 Type: Goods
View GEM

XLPE Cable for Working Voltages up to and Including 1.1 KV as per IS 7098 (Part 1)

South Eastern Railway

⏰ Deadline: 4 weeks left
🛒 Type: Goods
View GEM

Urban Development Department Uttar Pradesh High Mast Lighting Tower with LED Flood Lighting System Tender 2026

N/a

📍 HARDOI, UTTAR PRADESH

EMD: ₹2.4 L
Est: ₹56.7 L
⏰ Deadline: 4 weeks left
🛒 Type: Goods
View GEM