5 Part Automated Hematology Analyser (V2)
Bhavnagar District Panchayat
BHAVNAGAR, GUJARAT
Bid Publish Date
29-May-2026, 12:15 pm
Bid End Date
09-Jun-2026, 12:00 pm
EMD
₹19,000
Value
₹9,50,000
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
Regional Institute Of Paramedical & Nursing Sciences(ripans) announces a tender for 5 Part Automated Hematology Analyser (V2) (Q2) in AIZAWL, MIZORAM. Quantity: 1. Submission Deadline: 09-06-2026 12: 00: 00. Last date to apply is approaching fast!
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
5 Part Automated Hematology Analyser (V2) (Q2)
Trusted by 5,000+ companies to find, track, and win government tenders.
Our team will walk you through the platform and help set up your profile — free, no commitment.
Our team will reach out to schedule your free session.
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
Bhavnagar District Panchayat
BHAVNAGAR, GUJARAT
N/a
Indian Air Force
Rangareddi, TELANGANA
Indian Navy
KANNUR, KERALA
Indian Army
ALLAHABAD, UTTAR PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL | Product Description | 5 Part Automated Hematology Analyser |
| PRODUCT INFORMATION | Type of Configuration | Benchtop |
| PRODUCT INFORMATION | Type of system offered | Closed system |
| PRODUCT INFORMATION | Type of automation | Fully Automatic |
| PRODUCT INFORMATION | Equipment should have automatic start up,shut down and sample analysis | Yes |
| PRODUCT INFORMATION | Analysis principle | Laser based scatter analysis |
| PRODUCT INFORMATION | Type of cell counting | 5 part WBC differential without Retic and NRBC enumeration capability |
| PRODUCT INFORMATION | Should have multi channel analysis for better resolution and reproductability | Yes |
| PRODUCT INFORMATION | Analysis available | WBC, Lympho#, Lympho%, Neutrophil#, Neutrophil %, Basophil#, Basophil%, Easinophil #, Easinophil%, Monocyte#, Monocyte%, RBC, HGB, MCV, PCV, MCH, MCHC, RDW-SD, RDW CV, PLT, MPV, PDW, PLT, PLCR, PLCC, HCT, PCT, RET#, RET%, NRBC# |
| PRODUCT INFORMATION | NRBC% | No |
| PRODUCT INFORMATION | Availability of body fluid (CSF, synovial, serous) parameters like WBC-BF, RBC-BF, MN#, MN%, PMN%, PMN#,TC-BF# | No |
| PRODUCT INFORMATION | IPF analysis | No |
| PRODUCT INFORMATION | PLT-0 Analysis | No |
| PRODUCT INFORMATION | PLT-F Analysis | No |
| PRODUCT INFORMATION | IG % analysis | Yes |
| PRODUCT INFORMATION | IG# analysis | No |
| PRODUCT INFORMATION | RET-HE analysis | No |
| PRODUCT INFORMATION | HFR analysis | No |
| PRODUCT INFORMATION | LFR analysis | No |
| PRODUCT INFORMATION | MFR analysis | No |
| PRODUCT INFORMATION | IRFanalysis | No |
| PRODUCT INFORMATION | Discrete analysis modes available | CBC,CBC+DIFF |
| PRODUCT INFORMATION | Analysis method for WBC | Tri-angle Laser flow cytometry |
| PRODUCT INFORMATION | Method for platelet measurement | Electrical impedance |
| PRODUCT INFORMATION | RBC Measurement method | Electrical Impedance |
| PRODUCT INFORMATION | Hb measurement | Cyanide free colorimetry |
| PRODUCT INFORMATION | Retic measurement | Not provided |
| PRODUCT INFORMATION | Number of sample racks to cater to different tube sizes | 1 |
| PRODUCT INFORMATION | Maximum sample Aspiration volume needed in all modes | 20µl or less |
| PRODUCT INFORMATION | Minimum sample volume required in all modes | 20µl or less |
| PRODUCT INFORMATION | Throughput capacity in CBC/Differential | 50-60 |
| PRODUCT INFORMATION | Throughput capacity in Retic mode | NA |
| PRODUCT INFORMATION | Type of modes of sample running | Open vial |
| PRODUCT INFORMATION | Linearity of Platelet | 0 to 3000 * 10 3 cells/ micro litres |
| PRODUCT INFORMATION | RBC Linearity | 0 to 8 x 10^6 per micro litre or more |
| PRODUCT INFORMATION | Hemoglobin linearity | 0 to 25 gm per litre |
| PRODUCT INFORMATION | Retic linearity | NA |
| PRODUCT INFORMATION | WBC linearity | 0 to 300 * 1000 cells/ micro litres |
| PRODUCT INFORMATION | Directly measures MCV | Yes |
| PRODUCT INFORMATION | Time taken by the analyser to produce the test results(Analysis time) in seconds | 40-60 |
| PRODUCT INFORMATION | Availability of Auto dilution | No |
| PRODUCT INFORMATION | Clot detection facility | No |
| PRODUCT INFORMATION | Automatic probe wipe | Yes |
| PRODUCT INFORMATION | Extended Analyses for cytopenic samples | Yes |
| PRODUCT INFORMATION | Quality assurance system with calibration and controls | Yes |
| PRODUCT INFORMATION | Number of quality control programs | Atleast 3 |
| PRODUCT INFORMATION | Type of Calibration | Both manual and automatic |
| PRODUCT INFORMATION | Direct aspiration for capillary blood from finger prick | No |
| PRODUCT INFORMATION | Floating discriminator for platelets and RBC counting for reliable RBC and PLT data | Yes |
| PRODUCT INFORMATION | Separate diluting nozzles for RBC and WBC | Yes |
| PRODUCT INFORMATION | Double bathing mechanism | Yes |
| PRODUCT INFORMATION | Upgradable to integrate with attachment | No |
| Data Management and Display | Type of data management | In-built system |
| Data Management and Display | Display | LCD, LED Or higher |
| Data Management and Display | PC hard disk | NA |
| Data Management and Display | Inbuilt monitor size in inches | >5 |
| Data Management and Display | Processor of PC Provided with system | NA (If PC not provided) |
| Data Management and Display | RAM | NA (If PC not provided) |
| Data Management and Display | HDD | NA (If PC not provided) |
| Data Management and Display | PC Monitor size if PC provided externally | NA (for Inbuilt based) |
| Data Management and Display | The processor and RAM of the board system should be latest version | Yes |
| Data Management and Display | HIS/LIS Interface | HL7 |
| Data Management and Display | Type of external storage | USB |
| Data Management and Display | Number of USB Port provided | 4 |
| Data Management and Display | Type of printer unit | External |
| Data Management and Display | Printer type | Black and White Laser Printer |
| Data Management and Display | Display and print provided | Scatter plot and histograms |
| Data Management and Display | Auto loader facility | Yes |
| Data Management and Display | Facility for user defined flagging | Yes |
| Data Management and Display | Database capability of storing sets of results and graphics | ≥ 50000 |
| Data Management and Display | L J Plot facility | Yes |
| Data Management and Display | Delta check for cumulative review | No |
| Data Management and Display | On-line QC option | Yes |
| Data Management and Display | Patient moving average | Yes |
| Data Management and Display | QC File management | Yes |
| Data Management and Display | Facility for workload recording | Yes |
| Data Management and Display | Flagging in event of unacceptable control data | Yes |
| Data Management and Display | Ability to transmit results to host computer | Yes |
| Data Management and Display | Type of user Interface or data entry | Touchscreen, Handheld barcode reader facility, Manual |
| Data Management and Display | Have auto cleaning function in the analyser’s software | Yes |
| POWER REQUIREMENTS | Type of power supply | 100-240 VAC,50-60 Hz |
| POWER REQUIREMENTS | Power Backup facility | UPS |
| POWER REQUIREMENTS | Type of UPS | Offline |
| POWER REQUIREMENTS | Rating of UPS in KVA | 0.5 |
| POWER REQUIREMENTS | Back up time in minutes | 30, 60, 90, 120 Or higher |
| POWER REQUIREMENTS | Availability of Sufficient Number of Quality control files which store 100 or more XB Analysis | Yes |
| ACCESSORIES, SPARE PARTS AND CONSUMABLES | Offered equipment unit to be supplied with sufficient consumables (with at least 2/3rd of total shelf life) required for, sufficient to carry out haematological testing of samples" | 500 |
| ACCESSORIES, SPARE PARTS AND CONSUMABLES | Should have on board reagent facility and automatic reagent inventory management | Yes |
| ACCESSORIES, SPARE PARTS AND CONSUMABLES | Net work integration with lab information system feature | Yes |
| ACCESSORIES, SPARE PARTS AND CONSUMABLES | Operating temperature and humidity | Capable of operating continuously in ambient temperature of 10 to 35 deg C and relative humidity of 15 to 85% in ideal circumstances |
| CERTIFICATION AND REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION AND REPORTS | Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATION AND REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATION AND REPORTS | Availability of Test Report for product as per Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATION AND REPORTS | Electrical Safety Standards | IEC/EN 60601-1 or equivalent BIS Standard |
| CERTIFICATION AND REPORTS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes |
| WARRANTY | Warranty in years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 3, 5 Or higher |
| MISCELLANEOUS REQUIREMENTS | OEM/Reseller shall ensure uninterrupted availability of all spares for 10 years | Yes |
| MISCELLANEOUS REQUIREMENTS | Availability of toll free facility for technical support maintened by OEM or authorized agencies | Yes |
| MISCELLANEOUS REQUIREMENTS | User/Technical/Maintenance manuals to be supplied in English in hard and soft copy | Yes |
| MISCELLANEOUS REQUIREMENTS | Details of equipments and procedures required for local calibration and routine maintenance to be supplied and advanced maintenance task documentation also to be furnished | Yes |
| MISCELLANEOUS REQUIREMENTS | List of important spares and accessories, with their part numbers to be supplied to the buyer at the time of supplying the equipment | Yes |
| MISCELLANEOUS REQUIREMENTS | Installation and Demonstration of equipment and training to be provided after completing supplies before acceptance | Yes |
| MISCELLANEOUS REQUIREMENTS | The Principal Manufacturer must have direct Presence/approved service center In India | Yes |
| MISCELLANEOUS REQUIREMENTS | Calibration certificates as per NABH requirement | Yes |
| MISCELLANEOUS REQUIREMENTS | Time to attend breakdown calls | within 48 hrs |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
North Western Railway
📍 JAIPUR, RAJASTHAN
Hll Infra Tech Services Limited
📍 NEW DELHI, DELHI
Central Council For Research In Ayurvedic Sciences
📍 MANDI, HIMACHAL PRADESH
Directorate Of Purchase And Stores
📍 CHITTORGARH, RAJASTHAN
N/a
📍 SURENDRA NAGAR, GUJARAT
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS