CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
KORAPUT, ODISHA
Directorate Of Medical Education And Training
BAHRAICH, UTTAR PRADESH
N/a
LUCKNOW, UTTAR PRADESH
National Rural Health Mission
KHORDHA, ODISHA
Employees State Insurance Corporation (esic)
CHENNAI, TAMIL NADU
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL FEATURES | Product Name | Portable Impedence Audiometer |
| GENERAL FEATURES | Type | Screening and Diagnostic |
| GENERAL FEATURES | Patient Usage | Newborn, Infants and Children |
| PRODUCT INFORMATION | Probe Tone Amplitude (Hz) | 226 Hz +/-2%, 85+/-3 dB SPL and 1000 Hz +/-2%, 83+/-3 dB SPL |
| PRODUCT INFORMATION | Maximum Total Hormonic Distortion (%) | 3 |
| PRODUCT INFORMATION | Signal type | Continuous Sinusoid |
| PRODUCT INFORMATION | Pressure Measurement System direction of sweep | Positive to Negative pressure |
| PRODUCT INFORMATION | Sweep rate ( daPa/sec) | 400 |
| PRODUCT INFORMATION | Pressure Range (daPa) | +200 to -600 |
| PRODUCT INFORMATION | Accuracy | +/-15% or 10 daPa which ever is higher |
| PRODUCT INFORMATION | Multiple Probe Frequencies for Tympanometry (Hz) | 226, 678, 800, 1000 |
| PRODUCT INFORMATION | Automatic and Manual Tympanometry with selectable Pressure Ranges and Pump Speeds | Yes |
| PRODUCT INFORMATION | lpsi lateral and Contra lateral Reflex | Yes |
| PRODUCT INFORMATION | Accoustic Reflex decay | Yes |
| PRODUCT INFORMATION | ETF for Intact and Perforated Ears | Yes |
| PRODUCT INFORMATION | Stimulation for Reflex measurements | 250, 500, 1000, 2000, 4000, BBN, LBN, HBN |
| PRODUCT INFORMATION | Intensity range for Reflex | 35 to 120 (Upto 110) db HL with increment of 1 db |
| PRODUCT INFORMATION | Standard and pediatric ear tips provided with the device | Yes |
| USER INTERFACE AND ELECTRICAL FEATURES | User interface | With LCD display |
| USER INTERFACE AND ELECTRICAL FEATURES | Facility to connect external monitor | Yes |
| USER INTERFACE AND ELECTRICAL FEATURES | PC Interface | Yes |
| USER INTERFACE AND ELECTRICAL FEATURES | In-built printer | Yes |
| USER INTERFACE AND ELECTRICAL FEATURES | Facility to connect external printer | Yes |
| USER INTERFACE AND ELECTRICAL FEATURES | Suitable data base management software to be supplied along with the machine | Yes |
| USER INTERFACE AND ELECTRICAL FEATURES | Power supply | 220-240 VAC, 50Hz |
| USER INTERFACE AND ELECTRICAL FEATURES | Battery operated | No |
| USER INTERFACE AND ELECTRICAL FEATURES | Minimum battery back-up time (minutes) | 120, NA |
| PACKING MODE | Packing kit contains Product operating manual, warranty card, Impedance Audiometer in strong ABS housing, Dehumidifier, Cleaning brush, Cleaning cloth, Battery and carrying box | Yes |
| PACKING MODE | Packing | Individually packed |
| CERTIFICATIONS & REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Availability of valid Medical Device license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATIONS & REPORTS | Electrical Safety Standards | IEC 60601 or equivalent BIS |
| CERTIFICATIONS & REPORTS | Availability of Test Report for each supplied batch/product as per Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes |
| WARRANTY | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 1, 2, 3, 4, 5 Or higher |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC)
OEM Authorization Certificate
OEM Annual Turnover *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
N/a
📍 LUCKNOW, UTTAR PRADESH
Employees State Insurance Corporation (esic)
📍 MUMBAI, MAHARASHTRA
N/a
📍 CENTRAL DELHI, DELHI
N/a
📍 DAMAN, DAMAN & DIU
Damodar Valley Corporation
📍 KODERMA, JHARKHAND
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS