Chhattisgarh Health & Family Welfare ABR Screener Tender Raipur 2026 MDR 2017 Compliance
N/a
RAIPUR, CHHATTISGARH
Bid Publish Date
24-Jun-2026, 11:23 am
Bid End Date
15-Jul-2026, 11:00 am
Location
Progress
Quantity
1
Bid Type
Two Packet Bid
N/a invites bids for Automatic Auditory Brainstem Response (ABR) Screener (V2) - RBSK (Q3) in DAMAN, DAMAN & DIU. Quantity: 1. Submission Deadline: 15-07-2026 11: 00: 00. Submit your proposal before the deadline.
Tender Category
Goods
Bid To RA
No
Bid To RA Enabled
No
Item Category
Automatic Auditory Brainstem Response (ABR) Screener (V2) - RBSK (Q3)
End-to-end support — bid preparation, GeM registration, document filing & compliance by industry experts.
Free consultation · 24h response
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS
N/a
RAIPUR, CHHATTISGARH
All India Institute Of Medical Sciences (aiims)
Health Services
AIZAWL, MIZORAM
N/a
MUZAFFARPUR, BIHAR
All India Institute Of Medical Sciences (aiims)
GUNTUR, ANDHRA PRADESH
Tender Results
Loading results...
| Category | Specification | Requirement |
|---|---|---|
| GENERAL FEATURES | Product description | Automatic Brainstem Response (ABR) Screener |
| GENERAL FEATURES | Patient application | Children from 0-6 years |
| TECHNICAL SPECIFICATIONS | Lightweight & Portable Design | Yes |
| TECHNICAL SPECIFICATIONS | Easy to screen new born and young children | Yes |
| TECHNICAL SPECIFICATIONS | Electrode Type | Inbuilt reusable electrodes |
| TECHNICAL SPECIFICATIONS | Fast and automatic ABR-screening | Yes |
| TECHNICAL SPECIFICATIONS | Facility for automatic display of reliable results within seconds | Yes |
| TECHNICAL SPECIFICATIONS | Facility to edit the protocol used for screening | Yes |
| TECHNICAL SPECIFICATIONS | Stimulus Type | Click and Chirp |
| TECHNICAL SPECIFICATIONS | Variable Stimulation Level (Minimum) | 35 db nHL |
| TECHNICAL SPECIFICATIONS | Frequency for Screening Test (Hz) | 135-1500Hz, 1500-8000 Hz |
| TECHNICAL SPECIFICATIONS | Provision of Automatic Impedance Check indicating impedance conditions | Yes |
| TECHNICAL SPECIFICATIONS | Includes Software for screening AABR, upgradable to higher version | Yes |
| TECHNICAL SPECIFICATIONS | Additional follow-up measuring modes of Time-Step-Stimulus and standard ABR | Yes |
| TECHNICAL SPECIFICATIONS | Complete unit to be easily washable and sterilizable using both alcohol and chlorine agents | Yes |
| TECHNICAL SPECIFICATIONS | Results should be stored in computor/laptop | Yes |
| TECHNICAL SPECIFICATIONS | USB connection for power supply and data trasfer | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | Stainless steel electrodes (Nos) | 1 |
| STANDARD ACCESSORIES AND CONSUMABLES | Stainless steel electrodes for pre-matures (Nos) | 1 |
| STANDARD ACCESSORIES AND CONSUMABLES | Gel protection for electrodes | 1 set of 3 pieces |
| STANDARD ACCESSORIES AND CONSUMABLES | Electrode gel bottle (ml) | 250 ml |
| STANDARD ACCESSORIES AND CONSUMABLES | Compatible insert receivers | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | Carrying Bag | Yes |
| STANDARD ACCESSORIES AND CONSUMABLES | USB Cable | Yes |
| MINIMUM COMPUTOR, LAPTOP OR TAB REQUIREMENTS | Operating system | Windows, Android, IOS |
| MINIMUM COMPUTOR, LAPTOP OR TAB REQUIREMENTS | Processor | Intel Pentium P4 compatible or better |
| MINIMUM COMPUTOR, LAPTOP OR TAB REQUIREMENTS | Minimum RAM size | 4 GB or Better |
| MINIMUM COMPUTOR, LAPTOP OR TAB REQUIREMENTS | Minimum Hard Disk Space | 5 GB free GB disk space or better |
| MINIMUM COMPUTOR, LAPTOP OR TAB REQUIREMENTS | Display | SVGA-Color Display 800x600 or better |
| MINIMUM COMPUTOR, LAPTOP OR TAB REQUIREMENTS | Interface | USB 1.1 or 2 or Better |
| ELECTRICAL REQUIREMENTS | Power Requirements for ABR Screener | 220-240Vac; 50/60 HZ along with rechargeable inbuilt battery |
| ENVIRONMENTAL REQUIREMENTS | Capable of being stored continuously in ambient temperature of 0 to 50 degree C and relative humidity of 15 to 90% | Yes |
| ENVIRONMENTAL REQUIREMENTS | Capable of operating continuously in ambient temperature of 10 to 40 degree C and relative humidity of 15 to 90% | Yes |
| CERTIFICATIONS & REPORTS | Compliance to Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Availability of valid drug license for the product issued from the competent authority defined under Drugs and Cosmetic Act 1940 and Rules made there under as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Manufacturing unit certification | ISO:13485 (Latest) |
| CERTIFICATIONS & REPORTS | Electrical Safety Standards | IEC/EN 60601-1 or equivalent BIS Standard |
| CERTIFICATIONS & REPORTS | Availability of Test Report for each supplied batch/product as per Medical Device Rules (MDR) 2017 as amended till date | Yes |
| CERTIFICATIONS & REPORTS | Submission of all necessary certifications, licenses and test reports to the buyer at the time of bid submission and/or along with supplies as per buyer requirement | Yes |
| TRAINING AND INSTALLATION | Supplier to perform installation, safety and operation checks before handover | Yes |
| TRAINING AND INSTALLATION | Training of users in operation and basic maintenance shall be provided | Yes |
| TRAINING AND INSTALLATION | Calibration should be simple and user friendly and list of equipment and procedures required for local calibration and routine maintenance to be provided | Yes |
| TRAINING AND INSTALLATION | Technical Support and required spares and consumable till warranty period is over should be available | Yes |
| WARRANTY AND MAINTENANCE | Warranty in Years (Option of comprehensive warranty is available through bidding only, which if opted will supersede normal warranty in the catalogue) | 5 Or higher |
| WARRANTY AND MAINTENANCE | User, technical and maintenance manual in English detailing complete maintaining schedule should be provided | Yes |
| WARRANTY AND MAINTENANCE | Contact details of manufacturer, supplier and local service agent to be provided | Yes |
Discover companies most likely to bid on this tender
Experience Criteria
Past Performance
Bidder Turnover
Certificate (Requested in ATC) *In case any bidder is seeking exemption from Experience / Turnover Criteria
the supporting documents to prove his eligibility for exemption must be uploaded for evaluation by the buyer
Employees State Insurance Corporation (esic)
📍 MUMBAI, MAHARASHTRA
N/a
📍 CENTRAL DELHI, DELHI
N/a
📍 LUCKNOW, UTTAR PRADESH
Employees State Insurance Corporation
Indian Army
📍 COOCH BEHAR, WEST BENGAL
Sign up now to access all documents
Main Document
CATALOG Specification
ATC
GEM_GENERAL_TERMS_AND_CONDITIONS